Download AC Watt & Var Transducer

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power over Ethernet wikipedia , lookup

Wireless power transfer wikipedia , lookup

Ohm's law wikipedia , lookup

Electric power system wikipedia , lookup

Current source wikipedia , lookup

Stray voltage wikipedia , lookup

Electrification wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

History of electric power transmission wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Audio power wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power engineering wikipedia , lookup

Integrating ADC wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Three-phase electric power wikipedia , lookup

Rectifier wikipedia , lookup

Voltage optimisation wikipedia , lookup

Schmitt trigger wikipedia , lookup

Voltage regulator wikipedia , lookup

Mains electricity wikipedia , lookup

Surge protector wikipedia , lookup

Distribution management system wikipedia , lookup

Alternating current wikipedia , lookup

Current mirror wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
AC Watt & Var Transducer
Model SPW...WATT / Model SPK...Var
· Standard output with 0 to 1 mAdc
· Accuracy of reading base 0.25% reading
+ 0.02% ro
· High magnetic field immunity
· Meets IEEE SWC test
MODEL...SPW...SPK
101 - 1 phase 2 wires / 1 element
201 - 3 phase 3 wires / 2 elements
301 - 3 phase 4 wires / 3 elements
Description
HC model SPW-WATT & SPK-VAR transducers are designed to be an accurate unit, conversion by principle
of time devision multiplier as a function of sampling duty cycle as voltage & amplitude as current.
Rugged steel enclosure of magnetic field immunity & high electrical over capability, the units feture stable &
reliable field operation as industry, laboratories & process control for power measurement.
Specification
1.Accuracy
2.Input ( each element )
0.25% RD + 0.02%RO / 23 ± 3°C
Range
Over capability
Effective voltage 85-150V; current 0-6A
Voltage 200V continuous 250V ... 10sec / hour; 500V ... 2sec / hour
Current 15A continuous 50A ... 10sec / hour; 250A...1sec / hour ;
400A ... 0.5sec / hour
Burden
Voltage < 0.1VA at 120V input; current < 0.2VA at 5A input
Frequency
Watt 57-63Hz; Var 60Hz only
Protection
Full protection for SURGE, EMI & RFI
3.Output ( isolated with input )
Range
Outputload
Outputimpedance
Response time
Ripple
Long term stability
Temperaturestability
Adjustment
Protection
Magnetic effection
DC 0 to ±1mA
DC 0 to ±1mA calibration vs 0 to ± 500W / ± 500Var ... 1ø2W / 1 element
0 to ± 1000W / ± 1000Var ... 3ø3W / 2 elements
0 to ± 1500W / ± 1500Var ... 3ø4W / 3 elements
Maximum 10Kohm for 0 to ±1mA ouput
> 30 Mega ohm
< 400 ms from 0 to 99% RO at operating
< 0.5% P-P RO
< 0.1% RO per year ( typically )
< 0.01% per degree C, from 0 to 55°C
Span ± 5% / 10%; zero ± 2.5% / 5% on request
No damage ... open or short; full prtection ... SURGE, EMI, RFI
< 0.04% at center 400 A-T / M
4.Power supply
5.Operation condition
AC115 ± 20%, 50-70Hz, < 3VA
Environment
Temperature
Humidity
Elevation
Magnetic field
Waveform
-5 to 60°C
20 to 99% RH non condensed
Under 3000 meters
500 A-T / M
Watt - fundamental with 20% 3rd harmonics
Var - sinusoidual
Power factor
Any
Dielectric strength
4KV AC rms 1 minute between input / output / power / case IEC 688
Impulse test
ANSI C37.90/1989, IEEE 587/1983, IEC 255-3, 6KV ( 1.2 x 50 us ),
3KA ( 8 x 20 us ) .... current only
Surge test ( ring wave ) IEEE 587/1983 ( 3KV - 0.5us / 100KHz )
IEC 255-3 ( 2.5KV - 025ms / 1MHz )
Terminal Connection
*Terminal 1 & 2 for SPW-Watt only, terminal 3 & 4 for SPK-Var only
SPW 101 / SPK 101
1phase2wires
W+ W- Q+ Q-
SPW 201 / SPK 201
3phase3wires
Pm Pn
W+ W- Q+ Q-
SPW 301 / SPK 301
3phase4wires
P1 P2 P3
W+ W- Q+ Q- P0 P1 P2 P3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Output Output
Watt
Var
Output Output
Watt
Var
Output Output
Watt
Var
M
N
Load
R
S
T
Load
Power
Power
R
S
T
N
Load
Power
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16
9 10 11 12 13 14 15 16
1S
1S
1S 2S 3S 1L 2L 3L
1L
X
Y
3S 1L
3L
X
Y
X
Y