INPUT TECHNICAL SPECIFICATIONS AC CURRENT CT Input: 5A Secondary (1A Secondary Option) Burden: 0.2VA Overload: 2×CT for Continue 20×CT for 1 Second Full Scale:120% of CT Accuracy: 0.2% of Full Scale, True RMS AC VOLTAGE PT Pri/Sec: Direct or 100~500,000:100~400 Input Range: 20~400V Burden: <0.2VA Accuracy: 0.2% SWITCH STATUS (DI) Optical Isolated Voltage:4000Vac RMS Input Type: Wet Contact Resistance: 2K ohm (Typical) Input Voltage: 5~30Vdc Close Contact Voltage: 5V Max Input Current: 20mA METERING Parameter Voltage Current KW KVar KVA KWh KVarh Power Factor Frequency KW Demand KVar Demand KVA Demand Amps THD Volts THD Harmonic Accuracy (% of Full Scale) 0.2% 0.2% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% Resolution 0.1% 0.02% 0.1% 0.1% 0.1% 0.1KWh 0.1KVarh 0.1% 0.01Hz 0.1% 0.1% 0.1% 0.01% 0.01% 0.01% Range 20V to 500KV 0~9999 A -9999~9999 KW -9999~9999KVar 0~9999KVA 0~99999999.9KWh 0~99999999.9KWh -1.0~0~1.0 45~65Hz 0~9999KW 0~9999KVar 0~9999KVA 0~100% 0~100% 0~100% Acuvim Series Intelligent Power Meter ENVIRONMENTAL COMMUNICATION Ethernet Humidity: 95% non-condensing Temperature: -25°C to 70°C Packaging Shipping Box: 165mm×140mm×115mm Shipping Weight:0.5Kg Type: RS485 2 wire, half duplex, isolated Baud Rate:600 to 38400 bps Protocol: Modbus®RTU Function: Read/Write setpoints Read actual values Execute commands Modbus net POWER SUPPLY OUTPUT Input: 100V~240Vac 50/60Hz 100V~300Vdc Power:2W Ivorywhite DIMENSIONS 43.00 38.50 55.00 FRONT PANEL CUTOUT ORDERING Acuvim 100 * Option Input Voltage { Empty: PRIO: Indiablack Slategreen 90.00 SIDE Reactive Power Demand and Apparent Power Demand Time Limit: 0 to 76500ms in step of 300ms Max Positive Current: 30mA 90.00 CUT-OUT 96.00 ALARM OUTPUT Parameters:Frequency, Voltage, Current, Power, Reactive Power, Apparent Power, Power Factor, Voltage Unbalance Factor,Current Unbalance Factor, Power Demand, Output Form: Open Collector, NO Optical Isolated: 4000Vac rms Max Positive Voltage: 40Vac Max Negative Voltage:6Vdc Royalpurple 90.00 96.00 OUTPUT RELAY Type: Mechanical Contact Contact Resistance:30m ohm@1A Max Break Voltage:250Vac, 100Vdc Max Break Current:3A Configuration: Form A Contact material: Silver Alloy Output Mode: Latch or Momentary (50-3000ms Configurable) PULSE OUTPUT Parameters: KWh(import), KWh(export), KWh(net), KWh(total), KVarh (import), KVarh(export), KVarh(net), KVarh (total) Interval: 1 to 6000 in steps of 1 (0.1 KWh or KVarh) Pulse Width: 20ms to 1000ms in steps of 20ms Min Pulse Interval:20ms 2 Statue Imputs(DI) No DI Aux. Power No Relay No DO 4 Statue Inputs(DI) DI Aux. Power 2 Relays 2 DOs { 400: 100: 100Vac 400Vac Power System Metering Remote Switch Controlling Power Quality Monitoring Over/under Limit Alarming Remote Data Accessing Frame Color Selecting ISO9001 Certified North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: [email protected] Type Acuvim Acuvim+ Acuvim-S { Typical Ordering Code for Option: Acuvim-100-PRIO 070321016 DESCRIPTION √ √ √ √ √ LINE A B C √ LINE A B C 1A FUSE 5 I11 REAL TIME MEASURING DEMAND METERING ENERGY& POWER QUALITY 6 I12 Input/Output Option 8 I22 6 I12 Option module can provide additional 2 DIs, DI Auxilary Power, 2 DOs 7 I21 ACUVIM 8 I22 6 I12 7 I21 ACUVIM 8 I22 4 3 2 1 Vn V3 V2 V1 5 I11 6 I12 7 I21 ACUVIM 8 I22 9 I31 4 3 2 1 Vn V3 V2 V1 ACUVIM 9 I31 10 I32 10 I32 LOAD LOAD 2LL 1CT 1A FUSE Terminal Block 5 I11 10 I32 LOAD 2LL 2CT 4 3 2 1 Vn V3 V2 V1 9 I31 10 I32 LOAD LINE A B C 1A FUSE Terminal Block 5 I11 9 I31 1. There are two DIs in the basic Module of Acuvim and Acuvim . The and 2 Relay Outputs. 4 3 2 1 Vn V3 V2 V1 7 I21 + LINE A B 1A FUSE Terminal Block Terminal Block minute,Second 2. The 2 DOs may be used as Alarm or Pulse output. 34 √ √ √ R14 √ √ Protocol 33 √ Pulse Output Year,Month,date,Hour, Vaux<250Vac or 30Vdc I<3A Relay Output Vaux<40V,I<30mA Alarm Output 2LL 3CT With 2CTs Relay Output Modbus R13 √ √ TIME Real Time Clock Vaux<40V,I<30mA Energy Pulse Output 10 I32 √ TM Intermediate Relay LOAD Switch Status(DI) Over/Under Limit Alarm AC orDC 9 I31 √ MIN with Time Stamp 32 √ ACUVIM R12 K Factor MAX with Time Stamp 8 I22 Vaux 31 Current K factor 7 I21 Out RELAYOUTPUTS √ Vaux 38 THFF 4 3 2 1 Vn V3 V2 V1 37 √ TIF 6 I12 38 Voltage Crest Factor Crest Factor 5 I11 √ Aux Power R11 Terminal Block Harmonics 2nd to 31st 36 THD_Iavg Harmonics Acuvim 35 √ DIGITAL OUTPUTS √ DO1+ DO1- DO2+ DO2- THD_I1, THD_I2, THD_I3, Acuvim Acuvim-X 1A FUSE THD_Vavg 37 TICS LINE A B C 36 MONITORING 2LN 1CT 35 STATIS- √ 12V<Vaux<30V,I<20mA Digital input with External Power Supply LOAD DIGITAL OUTPUTS OTHERS √ √ 38 √ THD_V1,THD_V2,THD_V3, 37 Current Unbalance Factor I_unbl 36 √ 35 10 I32 √ √ AUX POWER 100~240Vac 50/60Hz 100~300Vdc 2W 34 Demand 33 √ Dmd_P,Dmd_Q,Dmd_S 32 √ 31 √ 14 Eq_imp,Eq_exp,Eq_total,Eq_net 13 √ Reactive Energy Vaux 12 √ 11 √ ACUVIM 9 I31 24 Ep_imp,Ep_exp,Ep_total,Ep_net 8 I22 23 Energy 7 I21 22 √ 21 √ 20 Frequency Acuvim 19 Frequency 6 I12 R DIGITAL OUTPUTS √ I DO1+ DO1- DO2+ DO2- √ R S4 4 3 2 1 Vn V3 V2 V1 R21 R22 √ PF1,PF2,PF3,PF 5 I11 R12 √ Power Factor I Terminal Block RELAY OUTPUTS √ R11 √ S1,S2,S3,Ssum G Q1,Q2,Q3,Qsum Apparent Power R NC Reactive Power I S3 N √ POWER √ NC P1,P2,P3,Psum L Power S2 S NC √ S1 I R 1A FUSE DIGITAL INPUTS √ V- √ LINE A B C N DI POWER I1,I2,I3,In,Iavg V+ Current DI3+ DI3- DI4+ DI4- √ 30 √ 29 √ 28 √ V12,V23,V31,Vllavg 27 √ Line Voltage 26 Acuvim √ DIGITAL INPUTS DIGITAL INPUTS DI1+ DI1- DI2+ DI2- DI3+DI3- DI4+ DI425 26 27 28 15 16 17 18 Acuvim V1,V2,V3,Vlnavg Voltage Unbalance Factor U_unbl Vaux power=15V,1W Digital input with internal DI Power Supply Acuvim-S Phase Voltage 25 2LN 2CT + 18 LOAD S NC 9 I31 10 I32 Acuvim S S4 DIGITAL INPUTS ACUVIM 8 I22 17 S3 7 I21 DI1+ DI1- DI2+ DI2- 6 I12 4 3 2 1 Vn V3 V2 V1 16 5 I11 15 S2 Terminal Block B 1A FUSE S1 Parameters FUNCTION COMM RS485 Port RS-485 LOAD LINE A B C N Comparison of Acuvim Acuvim+ and Acuvim-S Note: 10 I32 3LN 3CT With 2CTs Small Size 96×96 DIN one piece self-contained package Frame color optional I/O 9 I31 DO1+ DO1- DO2+ DO2- Power Quality: Voltage Harmonics 2nd to 31st and THD Current Harmonics 2nd to 31st and THD Voltage Crest Factor THFF (TIF) Current K Factor Voltage Unbalance Factor U_unbl Current Unbalance Factor U_unbl Max/Min Statistics with Time Stamps Switch Status 10 I32 LOAD Outline Current THD Acuvim 8 I22 9 I31 Clear and Large character LCD Screen display with blue back light Wide environment temperature endurable Monitoring 7 I21 ACUVIM 8 I22 Display Voltage THD 4 3 2 1 Vn V3 V2 V1 7 I21 Two DO outputs can be configured as Pulse output based on any two of KWh, KVarh or KVAh. The Pulse width or Pulse rate is Configurable. Metering 6 I12 Terminal Block 6 I12 RS485 Industry standard ModbusTM protocol Ethernet (RJ45) 4 3 2 1 Vn V3 V2 V1 5 I11 5 I11 Communication 1A FUSE Terminal Block 1A FUSE Pulse Output FEATURES V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg I1, I2, I3, In, Iavg P1, P2, P3, Psum Q1, Q2, Q3, Qsum S1, S2, S3, Ssum F PF1, PF2, PF3, PF Ep_imp, Ep_exp, Ep_total, Ep_net Eq_imp, Eq_exp, Eq_total, Eq_net Dmd_P, Dmd_Q, Dmd_S LINE A B C N Input/Output Option N A The limits of the less than 9 indicated parameters can be set with a specified time interval. If any input of the 9 indicated parameters is over or under its setting limit with persisting time over specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 9 indicated parameters can be any of the following 34 ones. F, V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg, I1, I2, I3, Iavg, In, P1, P2, P3, Psum, Q1, Q2, Q3, Qsum, S1, S2, S3, Ssum, PF1, PF2, PF3, PF, U_unbl, I_unbl, Dmd_P, Dmd_Q, Dmd_S LINE B C 29 30 Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis A Alarms AUX POWER V+ V- APPLICATIONS Two relay output can be used to remote control Electric Circuit Breaker. DIGITAL INPUTS DIGITAL INPUTS DI1+ DI1- DI2+ DI2- DI3+DI3- DI4+ DI415 16 17 18 25 26 27 28 The Acuvim series Intelligent Power Meter are an ideal choice when continuous monitoring of a power system is required. Some of the Electric Power parameters and functions packed into this pocket sized unit are: Energy Demand Power Quality Remote Control Over Range Alarm Statistics Records Programmable setpoints and two assignable outputs allow control functions to be added for specific applications. This includes basic alarm on over/under current, voltage, power, power factor, frequency, unbalance factor or demand and pulse output based on Energy or Reactive Energy. Status monitoring is possible using the 4 switch inputs. It combines high accuracy measurement with intelligent multi-function and simple HMI interface. The Acuvim may be used as a data gather device for an Intelligent Power Distribution Automation System or a Plant Automation System that integrates process, instrument and electrical requirements. All monitored values are available via a digital RS485 communication port running the Modbus™ protocol. Ethernet communication is also an option and with new wireless technologies and protocols currently under development, the applications for the Acuvim meter are limitless. The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined. Voltage Current Power Reactive Power Apparent Power Frequency Power Factor Energy Reactive Energy Demand TYPICAL WIRING Remote Control 1Phase 2Line (3LN 3CT) 1Phase 3Line (3LN 3CT) DESCRIPTION REAL TIME MEASURING METERING DEMAND ENERGY& POWER QUALITY Eq_imp,Eq_exp,Eq_total,Eq_net √ √ √ Demand Dmd_P,Dmd_Q,Dmd_S √ Current Unbalance Factor I_unbl √ √ √ √ 2LN 1CT LINE A B C Acuvim Aux Power √ √ √ LINE A B C 1A FUSE √ 5 I11 4 3 2 1 Vn V3 V2 V1 TICS 8 I22 6 I12 8 I22 9 I31 + 1. There are two DIs in the basic Module of Acuvim and Acuvim . The Option module can provide additional 2 DIs, DI Auxilary Power, 2 DOs 7 I21 ACUVIM Terminal Block 5 I11 6 I12 4 3 2 1 Vn V3 V2 V1 8 I22 6 I12 7 I21 ACUVIM 4 3 2 1 Vn V3 V2 V1 ACUVIM 8 I22 9 I31 9 I31 10 I32 10 I32 LOAD LOAD 2LL 1CT 5 I11 7 I21 ACUVIM 10 I32 LOAD 2LL 2CT 4 3 2 1 Vn V3 V2 V1 9 I31 10 I32 LOAD 1A FUSE Terminal Block 5 I11 7 I21 LINE A B C 1A FUSE Terminal Block Terminal Block Input/Output Option LINE A B 1A FUSE 6 I12 and 2 Relay Outputs. 34 √ LINE A B C minute,Second 2. The 2 DOs may be used as Alarm or Pulse output. R14 √ √ 33 √ √ Protocol R13 √ √ Year,Month,date,Hour, 32 √ Pulse Output Modbus R12 Relay Output TIME Real Time Clock Vaux<250Vac or 30Vdc I<3A Relay Output Vaux<40V,I<30mA Alarm Output 2LL 3CT With 2CTs √ COMM RS485 Port 31 √ √ TM Intermediate Relay LOAD Switch Status(DI) Over/Under Limit Alarm Vaux<40V,I<30mA Energy Pulse Output 10 I32 √ MIN with Time Stamp AC orDC 9 I31 √ K Factor MAX with Time Stamp ACUVIM RELAYOUTPUTS 8 I22 R11 7 I21 Vaux 38 √ Out 37 THFF Vaux 38 √ TIF 4 3 2 1 Vn V3 V2 V1 37 Voltage Crest Factor Crest Factor 6 I12 36 5 I11 35 Terminal Block √ Harmonics 2nd to 31st 36 THD_Iavg Harmonics DIGITAL OUTPUTS √ DO1+ DO1- DO2+ DO2- √ THD_I1, THD_I2, THD_I3, 35 Current THD I/O Note: Acuvim Acuvim-X 1A FUSE THD_Vavg DIGITAL OUTPUTS STATIS- THD_V1,THD_V2,THD_V3, 12V<Vaux<30V,I<20mA Digital input with External Power Supply LOAD √ √ Current K factor OTHERS 10 I32 DO1+ DO1- DO2+ DO2- MONITORING √ Reactive Energy Vaux 38 √ 37 √ ACUVIM 9 I31 36 Ep_imp,Ep_exp,Ep_total,Ep_net 8 I22 35 Energy 7 I21 34 √ Acuvim 33 √ 6 I12 R 32 Frequency I 31 Frequency R S4 4 3 2 1 Vn V3 V2 V1 14 √ 5 I11 13 √ 12 √ PF1,PF2,PF3,PF 11 √ Power Factor I Terminal Block 24 √ 23 √ S1,S2,S3,Ssum 22 Q1,Q2,Q3,Qsum Apparent Power R 21 Reactive Power I S3 20 √ DIGITAL OUTPUTS √ DO1+ DO1- DO2+ DO2- P1,P2,P3,Psum R21 R22 Power S2 R12 √ RELAY OUTPUTS √ R11 √ S1 I R 1A FUSE DIGITAL INPUTS I1,I2,I3,In,Iavg V- Current LINE A B C N DI POWER √ V+ √ DI3+ DI3- DI4+ DI4- √ 30 √ V12,V23,V31,Vllavg 29 √ Line Voltage 28 √ 27 Acuvim V1,V2,V3,Vlnavg DIGITAL INPUTS DIGITAL INPUTS DI1+ DI1- DI2+ DI2- DI3+DI3- DI4+ DI425 26 27 28 15 16 17 18 Acuvim Phase Voltage Voltage Unbalance Factor U_unbl Vaux power=15V,1W Digital input with internal DI Power Supply Acuvim-S 26 Parameters FUNCTION 25 2LN 2CT + G LOAD NC 9 I31 10 I32 18 Small Size 96×96 DIN one piece self-contained package Frame color optional Acuvim N S4 8 I22 DIGITAL INPUTS ACUVIM 7 I21 DI1+ DI1- DI2+ DI2- S3 6 I12 Outline 17 4 3 2 1 Vn V3 V2 V1 16 5 I11 15 S2 Terminal Block Comparison of Acuvim and Acuvim+ POWER S1 AUX POWER 100~240Vac 50/60Hz 100~300Vdc 2W NC 1A FUSE 19 LOAD L 10 I32 NC 9 I31 3LN 3CT With 2CTs LINE A B C N S NC 10 I32 LOAD Clear and Large character LCD Screen display with blue back light Wide environment temperature endurable Voltage THD Acuvim 8 I22 9 I31 S ACUVIM 8 I22 B 7 I21 RS-485 4 3 2 1 Vn V3 V2 V1 7 I21 Display Monitoring Power Quality: Voltage Harmonics 2nd to 31st and THD Current Harmonics 2nd to 31st and THD Voltage Crest Factor THFF (TIF) Current K Factor Voltage Unbalance Factor U_unbl Current Unbalance Factor U_unbl Max/Min Statistics with Time Stamps Switch Status 6 I12 RS485 Industry standard ModbusTM protocol Ethernet (RJ45) S 6 I12 Terminal Block Two DO outputs can be configured as Pulse output based on any two of KWh, KVarh or KVAh. The Pulse width or Pulse rate is Configurable. Metering 4 3 2 1 Vn V3 V2 V1 5 I11 5 I11 Communication 1A FUSE Terminal Block 1A FUSE Pulse Output FEATURES V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg I1, I2, I3, In, Iavg P1, P2, P3, Psum Q1, Q2, Q3, Qsum S1, S2, S3, Ssum F PF1, PF2, PF3, PF Ep_imp, Ep_exp, Ep_total, Ep_net Eq_imp, Eq_exp, Eq_total, Eq_net Dmd_P, Dmd_Q, Dmd_S LINE A B C N Input/Output Option N A The limits of the less than 9 indicated parameters can be set with a specified time interval. If any input of the 9 indicated parameters is over or under its setting limit with persisting time over specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 9 indicated parameters can be any of the following 34 ones. F, V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg, I1, I2, I3, Iavg, In, P1, P2, P3, Psum, Q1, Q2, Q3, Qsum, S1, S2, S3, Ssum, PF1, PF2, PF3, PF, U_unbl, I_unbl, Dmd_P, Dmd_Q, Dmd_S LINE B C 29 30 Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis A Alarms AUX POWER V+ V- APPLICATIONS Two relay output can be used to remote control Electric Circuit Breaker. DIGITAL INPUTS DIGITAL INPUTS DI1+ DI1- DI2+ DI2- DI3+DI3- DI4+ DI415 16 17 18 25 26 27 28 The Acuvim series Intelligent Power Meter are an ideal choice when continuous monitoring of a power system is required. Some of the Electric Power parameters and functions packed into this pocket sized unit are: Energy Demand Power Quality Remote Control Over Range Alarm Statistics Records Programmable setpoints and two assignable outputs allow control functions to be added for specific applications. This includes basic alarm on over/under current, voltage, power, power factor, frequency, unbalance factor or demand and pulse output based on Energy or Reactive Energy. Status monitoring is possible using the 4 switch inputs. It combines high accuracy measurement with intelligent multi-function and simple HMI interface. The Acuvim may be used as a data gather device for an Intelligent Power Distribution Automation System or a Plant Automation System that integrates process, instrument and electrical requirements. All monitored values are available via a digital RS485 communication port running the Modbus™ protocol. Ethernet communication is also an option and with new wireless technologies and protocols currently under development, the applications for the Acuvim meter are limitless. The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined. Voltage Current Power Reactive Power Apparent Power Frequency Power Factor Energy Reactive Energy Demand TYPICAL WIRING Remote Control 1Phase 2Line (3LN 3CT) 1Phase 3Line (3LN 3CT) INPUT TECHNICAL SPECIFICATIONS AC CURRENT CT Input: 5A Secondary (1A Secondary Option) Burden: 0.2VA Overload: 2×CT for Continue 20×CT for 1 Second Full Scale:120% of CT Accuracy: 0.2% of Full Scale, True RMS AC VOLTAGE PT Pri/Sec: Direct or 100~500,000:100~400 Input Range: 20~400V Burden: <0.2VA Accuracy: 0.2% SWITCH STATUS (DI) Optical Isolated Voltage:4000Vac RMS Input Type: Wet Contact Resistance: 2K ohm (Typical) Input Voltage: 5~30Vdc Close Contact Voltage: 5V Max Input Current: 20mA METERING Parameter Voltage Current KW KVar KVA KWh KVarh Power Factor Frequency KW Demand KVar Demand KVA Demand Amps THD Volts THD Harmonic Accuracy (% of Full Scale) 0.2% 0.2% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.2% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% Resolution 0.1% 0.02% 0.1% 0.1% 0.1% 0.1KWh 0.1KVarh 0.1% 0.01Hz 0.1% 0.1% 0.1% 0.01% 0.01% 0.01% Range 20V to 500KV 0~9999 A -9999~9999 KW -9999~9999KVar 0~9999KVA 0~99999999.9KWh 0~99999999.9KWh -1.0~0~1.0 45~65Hz 0~9999KW 0~9999KVar 0~9999KVA 0~100% 0~100% 0~100% Acuvim Series Intelligent Power Meter ENVIRONMENTAL COMMUNICATION Ethernet Humidity: 95% non-condensing Temperature: -25°C to 70°C Packaging Shipping Box: 165mm×140mm×115mm Shipping Weight:0.5Kg Type: RS485 2 wire, half duplex, isolated Baud Rate:600 to 38400 bps Protocol: Modbus®RTU Function: Read/Write setpoints Read actual values Execute commands Modbus net POWER SUPPLY OUTPUT Input: 100V~240Vac 50/60Hz 100V~300Vdc Power:2W Ivorywhite DIMENSIONS 43.00 38.50 55.00 FRONT PANEL CUTOUT ORDERING Acuvim 100 * Option Input Voltage { Empty: PRIO: Indiablack Slategreen 90.00 SIDE Reactive Power Demand and Apparent Power Demand Time Limit: 0 to 76500ms in step of 300ms Max Positive Current: 30mA 90.00 CUT-OUT 96.00 ALARM OUTPUT Parameters:Frequency, Voltage, Current, Power, Reactive Power, Apparent Power, Power Factor, Voltage Unbalance Factor,Current Unbalance Factor, Power Demand, Output Form: Open Collector, NO Optical Isolated: 4000Vac rms Max Positive Voltage: 40Vac Max Negative Voltage:6Vdc Royalpurple 90.00 96.00 OUTPUT RELAY Type: Mechanical Contact Contact Resistance:30m ohm@1A Max Break Voltage:250Vac, 100Vdc Max Break Current:3A Configuration: Form A Contact material: Silver Alloy Output Mode: Latch or Momentary (50-3000ms Configurable) PULSE OUTPUT Parameters: KWh(import), KWh(export), KWh(net), KWh(total), KVarh (import), KVarh(export), KVarh(net), KVarh (total) Interval: 1 to 6000 in steps of 1 (0.1 KWh or KVarh) Pulse Width: 20ms to 1000ms in steps of 20ms Min Pulse Interval:20ms 2 Statue Imputs(DI) No DI Aux. Power No Relay No DO 4 Statue Inputs(DI) DI Aux. Power 2 Relays 2 DOs { 400: 100: 100Vac 400Vac Power System Metering Remote Switch Controlling Power Quality Monitoring Over/under Limit Alarming Remote Data Accessing Frame Color Selecting ISO9001 Certified North America Toll Free: 1-877-721-8908 Web: www.accuenergy.com Email: [email protected] Type Acuvim Acuvim+ Acuvim-S { Typical Ordering Code for Option: Acuvim-100-PRIO 070321016