* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Programmable AC/DC Electronic load MODEL 63800 SERIES
Integrating ADC wikipedia , lookup
Standby power wikipedia , lookup
Automatic test equipment wikipedia , lookup
Standing wave ratio wikipedia , lookup
Josephson voltage standard wikipedia , lookup
Radio transmitter design wikipedia , lookup
Audio power wikipedia , lookup
Schmitt trigger wikipedia , lookup
Operational amplifier wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Valve audio amplifier technical specification wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Current source wikipedia , lookup
Current mirror wikipedia , lookup
Voltage regulator wikipedia , lookup
Surge protector wikipedia , lookup
Power electronics wikipedia , lookup
Opto-isolator wikipedia , lookup
Programmable AC/DC Electronic load MODEL 63800 SERIES Key Features : Power Rating: 1500W, 45000W Voltage Range: 50V - 350Vrms Current Range: Up to 45Arms Frequency Range: 45 to 440Hz, DC Real time power factor correction prevents over-stressing Crest Factor Range: 1.414 to 5.0 Power Factor Range: 0 to 1 CC,CR,CV,CP load modes Master/Slave parallel control mode for single or three phases PROGRAMMABLE AC/DC ELECTRONIC LOAD MODEL 63800 SERIES C h r o m a ’s 6 3 8 0 0 S e r i e s A C / D C Electronic Loads are designed for testing uninterruptible power supplies, AC sources and other power devices such as switches, circuit breakers, fuses and connectors. The power rating, paralleling and synchronization capabilities make the 63800 an ideal tool for high power AC test simulation. The 63800 Loads include voltage and current readback capability allowing users to observe the AC load current and output voltage of either discretely with via oscilloscope using analog outputs. In addition, the load provides TTL signals to control external relays for short circuit (crowbar) testing. The 63800 Loads can simulate high crest factor and varying power factor load conditions with real time correction base on voltage distortion. These special features provide real world simulation capability and prevent over-stressing that allow AC products to be tested automatically and reliability. The 63800 Series AC/DC Loads also provide necessary measurement functions along with GPIB & RS-232 interfaces for the most demanding engineering tests and ATE applications. Equipped with unique timing measurement functions, the 63800 Loads allow users to measure the battery discharge time, the protective time for fuse and breaker and UPS life cycle . UUT Voltage & Current Monitoring Timing Measurement Function for Battery, UPS, Fuse and Breaker tests 100 user programmable sequences via front panel for user friendly operation Measurement: V, I, PF, CF, P, Q S, F, R and Ip-/+ Short circuit simulation Full protection: OP,OC,OV and OT protection GPIB & RS-232C interfaces Other features of the 63800 Loads include built in fan speed control to minimize audio noise, internal self-diagnosis firmware and full protection against over-power, over-current and over-temperature. Model 63802 1.Application Specific Load Simulation The operating frequency range of the 63800 Loads is 45Hz to 440Hz as well as DC. Modes included are constant current, constant resistance, constant voltage and constant power as depicted below. When testing constant voltage devices like UPSs and AVRs, CC and CR modes are helpful in verifying these devices remain stable and/or within regulated limits under different current & resistance load settings. When testing battery chargers or other current source products, the output current changes according to the battery voltage (i.e. the output current varies with the output voltage). In these cases the loads CV mode is designed to force changes in output voltage allowing the load to be used to test battery chargers for correct charge current and battery voltage very precisely. In the case where the device under test is a battery or fuel cell, the 63800 load can simulate the behavior of various loads which these devices might be designed to drive. Many of this loads have power consumption patterns which are constant power in nature. Consequently, the Load CP mode is designed to simulate these load types and is essential for battery discharge loading. 2.Crest Factor & Power Factor with real time correction The specification range of CF is 1.414 to 5.0 and PF is 0 to 1 lead or lag (limited by crest factor). The 63800 load controls power factor by shifting the current relative to the input voltage to generate a displacement power factor. If the PF programmed is positive it will be a leading PF, negative programmed values result in a lagging PF. The CF & PF control is only used while in CC or CP modes with the operating range limit as figure 1. For example, for a programmed crest factor of 1.414, the power factor allowed is only 1 assume that the input voltage is 350Vrms sine-wave. However, for a programmed CF of 2.0, the PF may range from 0.608 to 0.85, for a programmed CF of 3.0, the PF may range from 0.211 to 0.6 and so on. Thus, if a higher desired power factor the lower the range of crest factors, and vice versa. Note also that when high crest factors are programmed some UUTs will respond with a distorted voltage waveform (see figure 2) which changes the resultant power factor. The 63800 AC load is capable to automatically (in real-time) shift the current waveform to maintain the desired power factor setting, thereby compensating for voltage distortion of the UUT’s output. PF CF Figure 1:Crest Factor vs.Power Factor control Range CF =Ipk/Irms PF =Active Power/Apparent power Figure 2 3.User Programming sequences The 63800 AC/DC Load includes 100 user programmable sequences with a time range from 10ms to 24 hour and count from 0 to 65535. A user friendly front panel input with power factor & crest factor control and GO/NG inspection for semi-automated test applications is also included. These features assist in many kinds of testing including UPS transient load simulation, high inrush current generation, short testing, engine start-up loading simulation, battery automated discharging, fuse and breaker life cycle testing and many others. 4.Master / Slave parallel control When higher power levels or three phase operations is required, the 63800 loads may be used parallel or combined for 3-phase loading. The 63800 loads allow for Master / Slave control mode whereby users only need to program the master unit; and slave units are automatically scaled and controlled by the master. In short, this allows several load units to work as a single load simplifying operation dramatically. 5.Comprehensive Measurements Chroma’s 63800 Series AC/DC Electronic Loads includes built-in 16-bits precision measurement circuits and firmware utilities to measure the steady-state and transient responses for true RMS voltage, true RMS current, true power(P), apparent power(S), reactive power(Q), crest factor, power factor and peak repetitive current . In additional to these discrete measurements, analog outputs for voltage and current are provided as a convenient means of monitoring these signals via an external oscilloscope. 6.Timing Measurement The 63800 AC/DC Load also includes unique timing measurement function allowing for time ranges between 0.1ms to 99999s. This feature allows users to set the final voltage & time out value to measure battery discharge time,A trigger voltoge can be set to measure the protective time of fuse & circuit breaker testing and UPS life cycle time record. 7.Panel Overview 3 2 1 4 1. LCD Display: For Setting and measurements read back. 2. Function key: To select load mode, control mode, and system 6 5 config setting. 3. Numeric key: For data setting. 4. Cursor key: For setting and editing. 5. Power switch 6. Rotary knob: It adjusts the loading and parameter setting. 7. Voltage sense terminal 8. Current monitor output: 7 8 9 10 11 12 13 14 Analog output to indicate the current waveform. 9. Voltage monitor output: Analog output to indicate the voltage waveform. 10. System I/O: Synchronous signal for master/slave parallel control 11. TTL I/O: For system input/output control signal 12. System Bus: For master/slave control system data communication 13. GPIB connector 14. RS-232C connector 15. AC Input connector 16. AC input voltage switch 15 6 •3 •8 •0 •0 16 17 17. Load terminal APPLICATIONS Relays, Switches Testing UPS/AVR Testing Avionics Testing of Military and Aircraft Breakers, Fuses Testing Transformers Testing 1. UPS & AVR Testing Uninterruptible Power Supplies (UPSs) and Auto Voltage Regulators (AVRs) are known as safe-guard systems. The 63800 is designed to provide precisely controlled non-linear loads with programmable crest factor and power factor to replace resistive load banks for testing these devices. This technology allows real world test conditions to be reliably and repetitive applied which are not possible with passive resistive loading. CC MODE CP MODE 2. Battery Test with Discharge Time Record Since power consumption patterns of most electronic devices are typical constant power in nature, Chroma's 63800 Electronic Load contant power mode is ideal for battery testing allowing for precise control & measurement of discharge loading with time record. CC MODE CP MODE 3. System Integration Chroma 63800 AC/DC Electronic Loads have GPIB, RS-232C and PC controllable interfaces. Additionally, external load ON/OFF by TTL signal, AC-ON signal output with /fault out signal and voltage / current monitoring capabilities make the 63800 Loads ideal for integration into automatic test system. Specifications Model 63801 63802 Power 1500W 4500W Current 0 to 15Arms (45Apeak) 0 to 45Arms (135 Apeak) Voltage 50 to 350Vrms (500 Vpeak) 50 to 350Vrms (500 Vpeak) Frequency 45 to 440Hz, DC 45 to 440Hz, DC Constant Current Mode Range 0 to 15Arms, Programmable 0 to 45Arms, Programmable Accuracy 0.1% + 0.2%FS 0.1% + 0.2%FS Resloution 1mA 3mA Range 7.5 Constant Resistance Mode 300 /300 3K 2.5 100 /100 Accuracy 0.5% + 0.5%FS 0.5% + 0.5%FS Resloution 20 u mho/ 2 u mho 50 u mho/ 5 u mho 1K Constant Voltage Mode Range 50~350Vrms, Programmable Accuracy 0.1% + 0.2%FS 50~350Vrms, Programmable 0.1% + 0.2%FS Resloution 100mV 100mV Range 1500W, Programmable 4500W, Programmable Accuracy 0.1% + 0.2%FS 0.1% + 0.2%FS Resloution 0.375W 1.125W Constant Power Mode Crest Factor Range 1.414 to 5.0, Programmable 1.414 to 5.0, Programmable Accuracy 1%FS 1%FS Resloution 0.005 0.005 Range 0 to 1, Programmable 0 to 1, Programmable Accuracy 1%FS 1%FS Resloution 0.001 Power Factor 0.001 DC Mode Voltage Range 7.5V to 500V 7.5V to 500V Current Range 0A to 15A 0A to 45A Min. operating voltage 7.5V 7.5V Rise time 75 us 75 us Operating Mode CC, CV, CR, CP Short Circuit Mode Max. Current @50ms Display Dot matrix 240x64, graphic mode (text mode at 1st stage) (TTL indicates high/ low when the short key is set on/off) Measurement DVM Range 0.0 to 350.0Vrms 0.0 to 350.0Vrms DVM Accuracy 0.1% + 0.1%FS 0.1% + 0.1%FS DVM Resloution 10 mV 10 mV DAM Range 0.0 to 50.00Arms 0.0 to 150.00Arms DAM Accuracy 0.1% + 0.1%FS 0.1% + 0.1%FS DAM Resloution 1.0 mA 2.5 mA PROGRAMMABLE AC/DC ELECTRONIC LOAD PROGRAMMABLE AC/DC ELECTRONIC LOAD PROGRAMMABLE AC/DC ELECTRONIC LOAD Other Specifications Vmonitor 500V/10V(Isolated) / 3%FS 500V/10V(Isolated) / 3%FS Imonitor 50A/10V(Isolated) / 3%FS 150A/10V(Isolated) / 3%FS Protection OCP:18Arms, OVP:380Vrms OCP: 48Arms, OVP:380Vrms OPP:1800W, OTP OPP:4800W, OTP Parallel Ability Yes Yes Interface External : GPIB, RS-232 , Internal : Can bus, TTL I/O Line Voltage 115/230 Vac (Pure) Inductive Load No No (Pure) Capacitive Load No No Dimension 4U 7U External load ON/OFF The AC load can be achieved by TTL high signal. AC-ON When AC Load is on, this pin turns into HIGH and turns into LOW 15% 115/230 Vac 15% when the load is off. /Fault out The voltage level of this pin is HIGH if AC load is in normal state. It turns into LOW when AC load is in protection state. (lol) low level output current = +1.25mA max. (Vol) low level output voltage = 0.5V max. All specifications are subject to change without prior notice. Ordering Information: 63801: Programmable AC Electronic Load 1500W/15A/350V 63802: Programmable AC Electronic Load 4500W/45A/350V V-I Curve Operating characteristics (Typical) of 63800 series Model 63801/63802 Model 63801/63802 AC mode DC mode 6 •3 •8 •0 •0 All specifications are subject to charge without notice. Developed and Manufactured by : Distributed by: CHROMA ATE INC. HEAD OFFICE 66,Hwa-Ya 1st Rd., Hwa-Ya Technical Park, Kuei-Shan Hsiang, Taoyuan Hsien 333,Taiwan Tel: +886-3-327-9999 Fax: +886-3-327-8898 http: //www.chromaate.com E-mail: [email protected] U.S.A. CHROMA ATE INC.(U. S. A.) 7 Chrysler ,Irvine, CA 92618 Tel : +1-949-421-0355 Fax : +1-949-421-0353 Toll Free:+1-800-478-2026 Europe CHROMA ATE EUROPE B.V. Max Planckstraat 4 6716 BE Ede, The Netherlands Tel : +31-318-648282 Fax : +31-318-648288 China CHROMA ELECTRONICS (Shen Zhen) Co.,Ltd. 8F, No.4, Nanyou Tian An Industrial Estate, Shen Zhen, China, PC: 518052 Tel : +86-755-664-4598 Worldwide Distribution and Service Network Fax : +86-755-641-9620 63800-931101-2000