Download Installation Instructions for L2004 Power Supply

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Pulse-width modulation wikipedia , lookup

Power factor wikipedia , lookup

Stray voltage wikipedia , lookup

Wireless power transfer wikipedia , lookup

Power inverter wikipedia , lookup

Standby power wikipedia , lookup

Electrical ballast wikipedia , lookup

Islanding wikipedia , lookup

Audio power wikipedia , lookup

Ground (electricity) wikipedia , lookup

Rectifier wikipedia , lookup

Buck converter wikipedia , lookup

Electric power system wikipedia , lookup

Electrical substation wikipedia , lookup

Metadyne wikipedia , lookup

Immunity-aware programming wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrification wikipedia , lookup

Rectiverter wikipedia , lookup

Alternating current wikipedia , lookup

Power over Ethernet wikipedia , lookup

Power engineering wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Earthing system wikipedia , lookup

Power supply wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

AC adapter wikipedia , lookup

Transcript
HALO®
INSTALLATION INSTRUCTIONS FOR L2004 POWER SUPPLY
WARNING
Avoid Fire or Electric Shock
• Follow installation instructions carefully.
• If unsure about electrical installation
consult a qualified electrician.
SAFETY INFORMATION
IMPORTANT SAFETY INSTRUCTIONS.
READ CAREFULLY FOR YOUR PROTECTION AND SAVE ALL INSTRUCTIONS.
•
•
•
•
•
•
•
•
Disconnect power before installing power supply on track.
Wear rubber-soled shoes and work on a sturdy wooden ladder.
This power supply must be installed according to the National Electrical Code and local building codes.
To avoid a hazard to children, account for all parts and destroy all packing materials.
If you are unsure about the installation or use of this power supply consult a qualified electrician.
CAUTION: To reduce the risk of fire and electrical shock, use only fixtures and fittings intended for use with Halo and Lazer by Halo
track systems only.
This device is not suitable for use with L963 Four-Circuit Track Adapter, L973 Canopy Adapter, L918 Series Extension Wands, L917
Slope Adapter, L972 C-Clamp Adapter, 477 Trac Adapter Trim, L967 Lampholder Adapter with Switch, L968 Lampholder Adapter
with Dimmer Switch, LZR209 and LZR210 Monopoints.
This device should not be used with wedge base lamp holders, LV301 and LV302
LOW VOLTAGE CAUTIONS
Applications
Low voltage electronic power supplies should not be installed in such a manor as to entrap excessive ambient heat around the power
supply such as enclosed display windows, showcases, alcoves, recessed covers, etc. Consult a qualified lighting designer if uncertain of
the suitability for a given application.
Dimming
Dimming quartz halogen lamps may reduce life and emit sound. Low voltage electronic power supplies require proper dimming equipment.
An improper dimmer may cause damage to the power supply and shorten lamp life. Using this device on more than one dimmer circuit
may produce interference between dimmer circuits. A magnetic inductor (choke) is recommended to reduce this condition in the dimmed
mode. Consult the dimmer manufacturer for dimmer equipment recommendations.
Operation
This device is designed to adapt Linea LV300 series low voltage fixture fittings to Halo and Lazer by Halo line voltage track. It converts the
120V 60HZ input to 12V 50W maximum. This device is overload and short circuit protected. In the event of an overload or short circuit, the
power supply will shut down and periodically attempt to restart. In the event of a shut down, clear the overload or short circuit and restart
the power supply. Please note the power supply has a soft start feature designed to extend the life of the lamp and reduce in-rush current.
Slow lamp turn on is normal operation.
NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A RADIO FREQUENCY LIGHTING
DEVICE PURSUANT TO PART 18 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION
AGAINST HARMFUL INTERFERENCE WITH ELECTRONIC DEVICES SUCH AS: RADIOS, TELEVISIONS, WIRELESS TELEPHONES OR
REMOTE CONTROLS. IF INTERFERENCE OCCURS IT MAY BE POSSIBLE TO CORRECT THE INTERFERENCE BY ONE OR MORE OF
THE FOLLOWING MEASURES:
•
•
•
REORIENT OR RELOCATE ANTENNA OF THE RECEIVING DEVICE.
INCREASE THE SEPARATION BETWEEN THIS EQUIPMENT AND THE DEVICE.
CONNECT THIS EQUIPMENT OR THE DEVICE INTO A DIFFERENT OUTLET OR CIRCUIT.
THIS EQUIPMENT SHOULD NOT BE USED:
•
CLOSER THAN THREE (3) FEET FROM ANY SENSITIVE ELECTRONIC EQUIPMENT.
•
NEAR MARITIME SAFETY, NAVIGATION, OR COMMUNICATIONS EQUIPMENT OPERATING BETWEEN 0.45 MHz AND 30 MHz.
Service
There are no user serviceable parts inside. Opening unit will void warranty. Contact point of purchase for service.
Customer First Center • 1121 Highway 74 South•Peachtree City, GA 30269 • 770.486.4800 • Fax 770.486.4801
702311
HALO®
Assembly
FIG 1
To install the LInea LV300 series fixture fitting to the power supply, align
the fixture fitting adapter as shown, insert into the mating slot while
holding the outside collar down and turn 90° allowing the tabs on the
collar to lock the fixture adapter to the power supply. Please refer to the
instruction sheet provided with the fixture fitting for additional
installation information (Fig. 2).
Installation
The L2004 power supply can be used with Halo and Lazer by Halo
single circuit track and Halo-2 two circuit track. An adjustable contact
allows you to select the circuit position. Use a narrow blade screwdriver
as shown to adjust the contact. Lift or lower the contact until it touches
the upper or lower plastic stop of the contact assembly (Fig. 3).
To use with Halo or Lazer by Halo single circuit track the adjustable
contact must be in the circuit #1 or lower position. To use with Halo-2
two circuit track adjust the contact position to the desired circuit
position, circuit #1 down or circuit #2 up position (Fig. 3).
To install the power supply to the track, insert the contact assembly
into the track and rotate the power supply 90° so the polarity line on
the power supply aligns with the polarity line on the track. Pull back and
release the thumb latch allowing the power supply to lock into position
(Fig. 4).
FIG 3
Circuit #2 (Up)
To remove the power supply, slide thumb latch down until latch is clear
of the track channel opening. Twist the power supply housing 90° until
the contact assembly is free and remove power supply from track
(Fig. 4)
Circuit #1 (Down)
FIG 1
Polarity Groove
FIG 4
Polarity Groove
Thumb Latch
L2004 Adapter
Track
Customer First Center • 1121 Highway 74 South•Peachtree City, GA 30269 • 770.486.4800 • Fax 770.486.4801