Control system wikipedia , lookup
Resilient control systems wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distribution management system wikipedia , lookup
Buck converter wikipedia , lookup
Installation Instructions Passive Infared Wall/Corner Mounted Low Voltage Occupancy Sensor Model # OAWC-P-120W Model # OAWC-P-120W-R P/N 9850-000140-01 Location Readallinstructionsonbothsidesofthissheetfirst Planallcomponentlocationscarefully InstallinaccordancewithALLlocalcodes Forindooruseonly • ForUsewithGreengateSwitchpacks&SystemsOnly • DonotrunanyGreengateLowVoltageWiringinthe sameconduitaspowerconductors Specifications Technology:PassiveInfrared(PIR) Power Requirements: Input: • 10-30VDCfromGreengateSwitchpackorGreengate system.Maximumcurrentneededis25mApersensor Output: • OpencollectoroutputtoswitchuptotenGreengate Switchpacks.BASwithIsolatedFormCRelay(-Rmodel) IsolatedFormCRelayRatings:1A30VDC/VAC Time Delays:Self-Adjusting,15seconds/test(10minAuto), orSelectable5,15,30minutes Coverage:1200sq.ft. Light Level Sensing:0to300foot-candles(-Rmodel) Operating Environment: • Temperature:32°F–104°F(0°C–40°C) • RelativeHumidity:upto90%non-condensing Housing: • Mediumimpactinjectionmoldedhousing PolycarbonateresincomplieswithUL94V0 Size:4.4"x3.4"x2"(112mmx86.4mmx50.8mm) LED Indicators:RedindicatesPIRdetection Themaximumcoverageareamayvarysomewhataccordingtoroomshapeandthe presenceofobstacles.Followthecoveragediagramconcerningmajorandminormotion coverage.Thesensormusthaveaclearviewoftheareatobecontrolled.Thesensorwill not“see”throughglass.Mountingheightshouldnotexceed12feet.Optimummounting heightis10feet.Mountthesensorsothedevicefacestheopenportionoftheroom and arefacinganearbywall,door,window,orotherobstructingobject.Avoidpointinginto hallways.Topreventfalseactivation,thesensorshouldbemountedawayfromtheair supplyductaminimumof4to6feet.Mountingatfixtureheightismosteffective.For typicalplacementrefertoLocationDiagram. Location Diagram Installation TheOAWC-P-120Wcanbemountedtothewall,ceiling,junctionboxorroundfixturewithraceway. TheOAWC-PWall/CornerMountLowVoltageOccupancySensorisaPassiveInfrared(PIR)motion sensinglightingcontrol,used forenergysavingsandconvenience.Whenmotionisdetected,thebluewireiselectronicallyconnectedtotheredwire,energizing therelayintheswitchpacktoturnONtheload.Ifvacancyisdetected,thebluewireisdisconnectedfromthered,causingtherelay toopenturningOFFtheload.Theredleadis10to30VDCsupply,theblackleadiscommonandtheblueistherelaycontrol. 1. MakesurepoweristurnedOFFatthebranchcircuitbreaker. 2. Wireunitsasshowninwiringdiagramsperapplicablevoltagerequirements.(Usetwist-onwireconnectorsforall connections)CAPALLUNUSEDWIRELEADS. 3. Mountunittowall,ceiling,junctionbox,orroundfixturewithraceway. 4. TurnpowerbackONatthebranchcircuitbreakerandwait2minutesfortheunittostabilize. 5. Makenecessaryadjustments.(SeeCheckoutandAdjustmentssection) Occupancy Sensor Mounted to Wallboard Occupancy Sensor Mounted to Drop Ceiling One Sensor, One Switchpack Coverage 24’ (7.3 mm) 20’ (6 mm) Occupancy Sensor Mounted to Octagon Box 12’ (3.7) Minor Motion, IR 8’ (2.4 mm) Major Motion, IR 0 8’ (2.4 mm) SENSOR WIRE LEAD LEGEND Black (Common) Red (10-30 VDC) Blue (Control) Yellow (Control) Brown (Switch-Blue Lead Control) Brown/White (Switch-Yellow Lead Control) Sensor’s Isolated Relay Orange (Normally Open) Gray (Common) Purple (Normally closed) Hot Line Neutral **Use Black Lead for 120 VAC Use Orange Lead for 277 VAC Cap Unused Lead Black (Common) Red (15 VDC) Blue (Control) Black Red Blue Yellow Brown Brown/White Orange Gray Purple Maximum coverage area may vary somewhat according to room shape and the presence of obstacles. The NEMA WD 7 Guide and robotic method were utilized to verify coverage patterns. 12’ (3.7) 10 ft (3 mm) Wiring CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD”. All installations should be in compliance with the National Electric Code and all state and local codes. NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling. Description PIR Technology Thesensor’ssegmentedlensdividesthefieldofviewintosensorzonesanddetectsthechangesintemperaturethatarecreated whenaperson,orpartofapersonassmallasahand,passesintooroutofasensorzone. Thesensorincludesself-adaptivetechnologythatcontinuallyadjuststoconditionsbyadjustingsensitivityandtimedelayinrealtime.Byadjustingsensitivityandtimedelayautomatically,thesensorismaximizingthepotentialenergysavingsthatareavailablein theparticularapplication. TheDaylightingfeature(-Rmodelonly)preventslightsfromturningONwhentheroomisadequatelyilluminatedbynaturallight. TheWalk-ThroughfeaturemaximizesenergysavingsbynotleavingthelightsONafteramomentaryoccupancy.Thesensor willswitchthelightsONwhenitdetectsapersonenteringthearea.Ifthesensordoesnotcontinuetodetectmotion30seconds following theinitialactivation,itwillautomaticallygotoashorter2minutetimedelay. InAutomaticOnMode,thelightsturnONwhenapersonenterstheroom.InManualONMode,thelightsareturnedONby activatingamomentaryswitch(model#GMDS-*)thatisconnectedtothesensor.Whenusedwith2levellighting(-Rmodelonly), bi-levelAutomaticONcanbeachievedwhichallowsZone1tocomeONautomaticallyuponoccupancy.Zone2doesnotcomeON unlesstheoccupantpressestheoptionalmomentaryswitch. Occupancy Sensor Mounted to Round Fixture with Raceway **Hot • • • • White Blue General Information Load 1 Blue Switchpack To Additional Sensors. Maximum of 5 sensors per switchpack. Optional Greengate GMDS SwitchBlue Control Lead-Manual ON/OFF Recommended Wire: 18-3 AWG stranded non-shielded 24’ (7.3 mm) 20’ (6 mm) 6 ft 15 ft (1.7 mm) (4.6 mm) 24 ft (7.3 mm) 50 ft (15.3 mm) Occupancy Sensor Mounted to Octagon Box with Mud Ring Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com One Sensor, Multiple Switchpacks Hot Black(Common) Red (15VDC) Blue (Control) Switchpack Sensor's Isolated Relay Orange (Normally Open) Gray (Common) Purple (Normally Closed) Black(Common) Red (15VDC) Blue (Control) Blue Blue **Use Black Lead for 120VAC Use Orange Lead for 277VAC Cap Unused Lead Load 1 White Neutral **Hot **Use Black Lead for 120VAC Use Orange Lead for 277VAC Cap Unused Lead Blue Black (Common) Red (10-30VDC) Blue (Control) Yellow (Control) Brown (Switch-Blue Lead Control) Brown/White(Switch-Yellow Lead Control) Hot Line Neutral White Line **Hot SENSOR WIRE LEAD LEGEND Field-of-view outside the space 1.AdjustPIRsensitivityto50%bymovingDIPSwitch5up. Load 2 Blue Switchpack To Additional Switchpacks 10 switchpacks Maximum Black Red Blue Yellow Brown Brown/White Orange Gray Purple Full and Half Logic Modes(SeeDIPSwitchlegend): InbothFullandHalfLogicmodes,lightsconnectedtotheyellowcontrolleadwillnotturnONuponoccupancy activation,shouldtheambientlightlevelexceedthepresetfoot-candlelevel. Optional Greengate GMDS SwitchBlue Control Lead- Manual on/off After activation: FullLogicMode–shouldtheambientlightlevelexceedthepresetfoot-candlelevel,thelightsconnectedtothe yellowcontrolleadwillturnOFF.ThelightswillremainOFF,untiltheambientlightlevelfallsbelowthesetpoint. HalfLogicMode–theoutputstateoftheyellowcontrolleadwillnotchangewithambientlightchanges,after occupancyactivation.Iftheamountofnaturallightavailablerisesabovethesetpoint,thedaylightsensorwillnotturn thelightsOFFwhileoccupancyisbeingdetected. DIP Switch Settings Time Delay Activation DIP Switch 1 2 Activation LEDs PIR Sensitivity Walk-Through Mode Power Pack One Power Pack Two 4 3 6 5 Override 7 Lighting Sweep Daylighting Mode 9 8 Auto* Auto Auto Full Disable Enable Disable Disable 5 Minutes Manual Manual 50% Enable Disable Enable Enable 15 Minutes Daylight Adjustments Ifthisfeatureisnotneeded,leavethelightlevelatmaximum(fullyCW). TheDaylightingfeature(-Rmodelonly)preventsthelightsfromturningONwhentheroomisadequatelyilluminated bynaturallight.Ifthereisenoughlightintheroomregardlessofoccupancy,thesensorwillholdthelightsOFF.Ifthere isnotenoughlightintheroom,thesensorwillallowthelightstoturnONwhenoccupied. (-R model only) 10 Half Full (-R model only) 30 Minutes *Self-Adjusts to 10 min. user mode Default = 1 2 3 4 5 6 7 8 9 10 Checkout and Adjustment AdjustmentsshouldbemadewiththeHVACsystemON.Useonlyinsulatedtoolstomakeadjustments. Self-Adjust SensorisshippedintheSelf-AdjustMode.ThisappliestotimedelayandPIRsensitivity.Inpreparationforthe InstallerTest,thetimedelayissetto15seconds,afterthesensorisinstalled,poweredONandhasstabilized,the unitwilltime-out15secondsafterthelastmotiondetected.Coverageandsensitivitycanbeconfirmedbywatching theRed(PIR)indicatorLEDsonthefrontofthesensor,whilemovingaroundtheroom. 1.WalkaroundtheroomandmonitorLEDs.LEDsshouldonlyturnONforonesecondwitheachmotion.(IfLEDs donotturnON,gotoInstallerAdjustments-SensitivityAdjustmentsSection) 2.Standstillsixtoeightfeetawayfromthesensorforfiveseconds.LEDsshouldnotturnON.(IfanyLEDturns ON,noteLEDandgotoInstallerAdjustments–SensitivityAdjustmentsection) 3.Walkoutsidetheroomandwait15secondsforthelightstoturnOFF.(IflightsdonotturnOFFgotoInstaller AdjustmentsSection) 4.Re-entertheroomtoactivatesensor.(IflightsdonotturnONgotoTroubleshootingSection) 5.TheunitwillremaininTestModefor5 minutesthenautomaticallyexitTestModeandgofor10min.Time DelayUserModesetting. Note:ToplaceintoTestMode,toggleDIPSwitch10outofitscurrentposition,wait3seconds,andthenbackintoitsoriginalposition.To forceinto10minUserModemoveDipSwitches1and2down.(IfDIPSwitches1and2arealreadydown,toggleDIPSwitch1outofitscurrent position,wait3seconds,andthenbacktoitsoriginalposition)WhileinTestMode,theLEDswillflashonceper1/4second. Installer Adjustments Note:Setthelightlevelwhentheambientlightisatthelevelwherenoartificiallightisneeded.Inorderforthis featuretofunction,theyellowcontrolleadmustbewired. 1.WiththeloadON,putthesensorintoTestMode.ToplaceintoTestMode,toggleDIPSwitch10outofitscurrent position,wait3secondsandthenbackintoitsoriginalposition. 2.SetDIPSwitch10toFullorHalfLogicMode. 3.Setthelightleveltominimum(fullyCCW). 4.Leavetheroomandletthesensortime-outsolightsareOFF.EnterthespaceandlightsshouldremainOFF. 5.MakesurenottoblockthesensorfromthedaylightsourceandadjustthelightlevelpotentiometerCWinsmall incrementsuntilthelightsareON.(Pause5secondsbetweeneachadjustment) 6.OncethelightsareON,theloadconnectedtothesensorwillnotturnONiflightlevelsareabovethe currentillumination. Time Delay Adjustments Peoplewhoremainverystillforlongperiodsoftimemayneedalongertimedelaythanthedefaultsettingof10 minutes.AslongasAutoisenabled,thesensorwillrespondtoeachpairoffalse-OFFswithnonormalOFFinbetween, byalternatelymakingslightadjustmentstoeithertimedelay(by2minuteincrements)orsensitivity,sothereshouldbe noneedformanualadjustment.Ifmanualadjustmentisdesired,refertoTimeDelaysettingsinDIPSwitchlegend. ResetsensortimedelaytofactorysettingsbymovingDIPSwitches1and2down.(IfDIPSwitches1and2are alreadydown,toggleDIPSwitch1outofitscurrentposition,wait3seconds,andthenbacktoitsoriginalposition) Automatic Mode InAutomaticONMode,thelightsturnONwhenapersonenterstheroom.Ifoptionalmomentarylowvoltage switchesareusedalongwithAutomaticONMode,activatingtheswitch(es)whiletheloadisONturnstheloadOFF. WhentheloadisturnedOFFmanually,aslongasthesensorcontinuestodetectoccupancytheloadsstayOFF.After thetimedelayexpires,thelightsstayOFFandthesensorgoesbacktoAutomaticONMode.Forwiringinformationfor theoptionalmomentarylowvoltageswitch(es),pleaseseethewiringsectionoftheinstallationinstructions. Manual Mode InManualONMode,theoptionalmomentarylowvoltageswitch(es)isrequiredtoturntheload(s)ON.Onceactivated thesensorwillmaintainthelightsONuntilmotionceasesandthetimedelayexpires.Whiletheroomisoccupiedthe BASrelayremainsactive.Afterthetimedelayexpires,theload(s)willautomaticallybeturnedOFFandtheswitch(es) mustbeusedtoturntheload(s)ONunlessthereismotiondetectedwithinthe10secondre-triggerperiod. Troubleshooting Issue Lights Will Not Turn ON automatically Lights Will Not Turn ON manually Possible Causes Suggestions WallswitchOFF TurnwallswitchON Iflowvoltageswitchoptionisused,lights mayhavebeenturned-offmanually Presslow-voltageswitch DaylightingFeatureEnabled IfalllightsarerequiredtoturnONadjustDIP Switch10and/ordaylightpotentiometer Powerinterruption Checkincomingvoltageand/orwiring DaylightingFeatureEnabled IfalllightsarerequiredadjustDIP Switch10and/ordaylightpotentiometer Powerinterruption Checkincomingvoltageand/orwiring If lights will still not turn ON, set sensor to override mode and call Technical Services at 1-800-553-3879 Lights Will Not Turn OFF automatically Lights Will Not Turn OFF automatically Override MakesuresensorisnotinOverrideMode(DIPSwitch8up) Sensorinstalledclosetoanairvent Sensorsshouldbeinstalled4-6feetaway fromanyairventandoutofheavyairflow Sensorinstalledclosetoindirectlighting Sensorsshouldbemountedawayfromindirectlighting Self-adjust Itmaybepossiblefortheunittohaveself-adjusted thetimedelaytoa30minutedelay.Ifthelightsdo notturnOFFafter30minutesfollownextstep 30MinuteDelay Maximumtimedelayis30Minutes.CheckDIP SwitchestoverifyDIPSwitchsettings.Iflightsdo notturnOFFatthesettimedelay,checknextstep PIRactivatedbyheatsourceotherthanoccupant MoveDIPSwitch5UP Bypass Checkwiringtomakesuresensor orswitchpackarenotbypassed Override MakesuresensorisnotinOverrideMode(DIPSwitch8up) If lights will still not turn OFF, call Technical Services at 1-800-553-3879 Warranties and Limitation of Liability Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions. Lighting Sweep Option Ifselected,thisDIPSwitchoptionforcesaninitial60seconddelayupon“power-up”topreventfalseactivationin buildingswithcomputercontrolsystems. 1.MoveDIPSwitch9UP. Override TheOverridesettingallowsthelightstoremainONintheunlikelyeventofsensorfailure. 1.MoveDIPSwitch8UP. WhileinOverrideMode,theoptionallowvoltagemomentaryswitch(es)willtogglethelightingload(s). Sensitivity Adjustments PIR Sensitivity 1.Standindifferentareasoftheroomandwaveyourhands. 2.IftheRedLEDdoesnotturnON,checkforanyobstructions. 3.Standstillsixtoeightfeetawayfromsensorforfiveseconds.LEDshouldnotturnON. 4.IfRedLEDturnsONwithoutmotionorisconstantlyONadjustPIRsensitivityto50%bymovingDIPSwitch5UP. Printed in Malaysia Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com