* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PDF
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power over Ethernet wikipedia , lookup
Rectiverter wikipedia , lookup
Distribution management system wikipedia , lookup
Greengate Technical Data CKM18, CKM36 & CKM48 ControlKeeper M Catalog# Prepared by Project Date Comments Type Overview ControlKeeper M network lighting control panels are scalable to any size application. The large view color touchscreen permits entire network programming and monitoring for complete system control and integration. Control up to 48 relays per panel with discrete inputs for occupancy sensors, low voltage switches and other input devices. ControlKeeper M network panels are designed for intuitive programming, and monitoring of the relays. The relays automatically sense the optimal time to switch lighting loads. Features True real-time power metering relay panel Capable of controlling receptacle loads Individually replaceable relays with arc suppression technology Programming stored in non-volatile memory Capable of mixed load voltages (120/277/347 VAC) as well as mixed sources (ie. normal and emergency power) 30 Amp relays are used on all 20A relay cards to extend relay life CKM18, CKM36 & CKM48 ControlKeeper M June 2015 Transformer Ratings Power Use Fully loaded panel 90 watts Ratings Operating Temperature: 32°F to 122°F (0°C to 50°C) Environment Master Override ON/AUTO/OFF or Individual relay control with status LED Programming Onboard TouchScreen Interface One panel or entire network Optional PC Software Standard Relay Normally open Ratings 20A, incandescent 120 VAC, ballast 277 VAC Maximum wire size: 8 AWG 1HP @ 120 VAC, 2HP @ 277 VAC Latching Relay Normally open, normally closed latching Ratings 20A,120/277 VAC 15A, 347 VAC Maximum wire size: 8 AWG 1HP @ 120 VAC, 2HP @ 277 VAC Two Pole Relay Normally open Ratings Maximum wire size: 6 AWG 20A, 208, 240/480 VAC Relays have a minimum 25K SCCR Standards UL Approval UL 508 Listed UL 924 with LRM Automation Interface Module Keeper Enterprise Software Ethernet Interface Module Digital Switch Dry Contact Switches Occupancy & Daylighting Sensors Dimensions Enclosure CKM 18: 31”H X 24”W X 6”D (up to 18 relays) CKM 36: 40”H X 24”W X 6”D (up to 36 relays) 24 in. (609.6 mm) 24 in. (609.6 mm) System Includes 24 in. (609.6 mm) Digital Switch interface 6 in. (152.4 mm) 0-10V inputs Time schedules with astronomic clock (152.4 mm) Timed inputs Occupant warn-off and overrides 31 in. (787.4 mm) Power Metering Onboard Ethernet port UL Listed - UL 924 with LRM www.eaton.com/lightingsystems 40 in. (1016 mm) mm) Prioritization and masking (609.6 of switch inputs, time schedules and remotes 48.25 in. (1225.55 mm) Controls receptacle loads with 6 in. module 24 in. latching relay 2 6 in. (152.4 mm) 24 in. (609.6 mm) NEMA 1 enclosure Low Voltage input connections 24 (609 CKM 48: 48.25”H X 24”W X 6”D (up to 48 relays) 6 in. (152.4 mm) 48.25 in. (1225.55 mm) NEMA 1 surface mount, lockable CKM18: 31”H X 24”W X 6”D (up to 18 relays) CKM36: 40”H X 24”W X 6”D (up to 36 relays) CKM48: 48.25”H X 24”W X 6”D (up to 48 relays) Wide input voltage power supply, 120-347 VAC 40 in. (1016 mm) Enclosure Size Accessories 31 in. (787.4 mm) Specifications 6 in. (152.4 mm) CKM18, CKM36 & CKM48 ControlKeeper M June 2015 Wiring Diagram Latching Relay Receptacle Control Sample One-Line Zone 1 Zone 2 Zone 3 Zone 4 GDS Cable type: Cooper LCCNP or Cooper LCCP or Belden 1502, maximum distance 1000 feet per GDS network Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 5 Zone 6 Zone 6 ControlKeeper M Relay Panel Power Metering Zone 1 Zone 2 Zone 3 ControlKeeper M Relay Panel Power Metering Zone 1 ControlKeeper T Relay Panel Zone 2 Zone 3 Zone 4 Zone 4 Zone 5 Zone 5 Zone 6 Zone 6 ControlKeeper 4A Distributed 0-10V Dimming panel Q1 SW1 X4 SRC PCI 2005 LINE 8 C1 LED1 7 LOAD 6 C C5 LED5 50-022110-01 DIGITA CAN-TX K1 5 Q2 4 U4 TB2 3 LED4 U2 MOV2 2 CAN-RX TB1 54-022510- SW2 1 MOV1 50-022510-00 ADDRESS LED3 ALL ON SW2 LED2 ALL OFF PCI-NET LINE LED1 NETWORK RS-232 K2 Q3 RSC PIC MOV3 SWIN PIC C14 TB3 U6 U2 K3 RSC STAT MOV4 L1 PE-52627 PE-52647 or Talema SWV-0-90-330 LED9 LINE LOAD SW4 U3 U4 LED7 STATUS SD1 Gnd K4 1 0 OHM OPT-47K RESET PICS TB4 LED5 LOAD SW3 LINE RS-232-SP PCI-NET TERM Q4 To other lighting control panels LED3 U1 LOAD 1 +NET -NET SWIN STAT 1 LED8 POWER TB2 J7 LOCAL REMOTE Ethernet link: Programming access or Power Metering data access PCI-NET Ethernet link: Programming access or Power Metering data access J8 ANALOG INPUTS TB3 ANALOG INPUTS +24 GND AN AN AN AN 1 2 3 4 ANALOG GND TB4 DIMMING OUTPUTS DIMMING OUTPUTS DO RTN DO RTN DO RTN 1 1 2 2 3 3 SWITCH INPUTS TB5 TB6 LSO TEST SWITCH INPUTS AND LIGHTED SWITCH OUTS DO RTN IN +24 4 4 1 IN LS 2 1 IN +24 IN LS 3 4 2 TP1 IN +24 IN LS IN 5 6 3 7 +24 IN 8 LS 4 To other lighting control panels Cable type: Belden 9841 or equal Maximum distance 4000 feet per network www.eaton.com/lightingsystems 3 CKM18, CKM36 & CKM48 ControlKeeper M June 2015 Ordering This is a network-ready lighting control system. It can be combined with other ControlKeeper series panels to create a scalable networked lighting control scheme. It can be ordered with any suitable system option or accessory. CKM - 18 - 6 - 5 - 2 - S - T - CCM1 - AN1 Product Analogs CKM= ControlKeeper M 0, AN1, AN2 = 18 Size 0, AN1, AN2, AN3, AN4 = 36 Size 0, AN1, AN2, AN3, AN4, AN5, AN6 = 48 Size (Dependent upon # of CCM’s, two AN’s for each CCM. Each AN supplies four analog 0-10V inputs) Panel Size 18 = 18 Size 36 = 36 Size 48 = 48 Size Inputs (Each CCM supplies 18 Contact Inputs 0, CCM1 = 18 Size 0, CCM1, CCM2 = 32 Size 0, CCM1, CCM2, CCM3 = 48 Size # of Latching Relays (Single Space) 0-18 = 0-18 for 18 Size panel 0-36 = 0-36 for 36 Size panel 0-48 = 0-48 for 48 Size panel Display # of Electrically Held Relays (Single Space) 0-18 = 0-18 for 18 Size panel 0-36 = 0-36 for 36 Size panel 0-48 = 0-48 for 48 Size panel NT = No TouchScreen T = TouchScreen Enclosure S = Surface # of Two Pole Relays (Single Space) 0-8 = 0-8 for 18 Size panel 0-18 = 0-18 for 36 Size panel 0-24 = 0-24 for 48 Size panel Additional Options Catalog # Description iBarrier Individual Relay Barrier, Voltage and Power Source Separation Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting Systems – Controls Products 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503010EN June 8, 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.