Download Download T2400 Datasheet

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spark-gap transmitter wikipedia , lookup

Electrification wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Electric power system wikipedia , lookup

Ground (electricity) wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Ohm's law wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Current source wikipedia , lookup

Three-phase electric power wikipedia , lookup

Islanding wikipedia , lookup

Immunity-aware programming wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical substation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Schmitt trigger wikipedia , lookup

Stray voltage wikipedia , lookup

Rectifier wikipedia , lookup

Earthing system wikipedia , lookup

Surge protector wikipedia , lookup

Power electronics wikipedia , lookup

Voltage regulator wikipedia , lookup

Buck converter wikipedia , lookup

Alternating current wikipedia , lookup

Current mirror wikipedia , lookup

Voltage optimisation wikipedia , lookup

Relay wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Protective relay wikipedia , lookup

Transcript
Protection Relays & Controls
Generator & Single-Function Protection–Overcurrent
T2400 Series
3-Phase Dual Overcurrent Relay
Description
The T2400 3-Phase Dual Overcurrent Relay includes two
combined overcurrent relays, designed for protection or
monitoring of generators and power transmissions. A typical
application is to use one of the overcurrent functions to trip the
generator circuit breaker, and the other overcurrent function to
trip a non-essential consumer.
The T2400 consists of two overcurrent circuits with similar
current settings and time delays. Each circuit detects the
highest of the 3 input currents and, if this exceeds the preset
level (0.5-1.4 x IN), the corresponding pick-up LED will indicate
and the delay timer will be started. After the preset time
(3-30 sec.) has expired, the corresponding output relay and
LED will be activated, provided that the current level was
exceeded for the entire delay time.
Simplified Circuit Diagram
U
I1
I2
I3
1
2
Features & Benefits
Features
SUPPLY
3
11
T2400
(3-Phase Dual
Overcurrent Relay)
I. OVERCURRENT
12
13
14
15
II. OVERCURRENT
16
Accepts high supply
voltage variation
10
9
8
7
6
5
4
Visual indication of
power, pick-up, and
output trip
Direct line-line or lineneutral voltage supply
(up to 690 Vac)
Combining 2 relays in
same enclosure
Galvanic isolated inputs
L1 L2 L3
DIN-rail or screw-mount
& adjustment by
potentiometers
Ordering Information
Terminals
Ordering
Number
1-3
T2400.0010
230 V
5A
T2400.0020
450 V
400 V 5 A
T2400.0030
110 V
100 V 5 A
T2400.0040
450 V
T2400.0050
480 V
output on relay 1,
400 V 5 A Latching
6-60 sec. delay on relay 1
415 V 5 A
T2400.0060
450 V
400 V 1 A
T2400.0070
450 V
T2400.0080
T2400.0090
2-3
IN
function
400 V 5 A Latching output on relay 1,
normally energized relay 1
127 V 120 V 5 A
24 Vdc
5A
Latching output relays are reset by disconnecting the power supply.
Other supply voltages and combinations are available on request.
BENEFITS
Ensures correct operation in spite of voltage
supply fluctuations (fulfills marine class
requirement)
Provides quick and concise status information
Simplifies design and installation.
No need for PTs.
Economic solution for non-essential load
tripping, and occupying less space in the
switch panel
Protects the unit against high AC voltage and
currents from the installation including spikes
Easy installation
Specifications
Trip Level
0.5-1.4 x IN
Delay
3-30 sec.
Max. Voltage
660 V
Voltage Range
60-110%
Consumption
Voltage 5 VA at UN
Current 0.3 VA at IN
Continuous Current
2 x IN
Frequency Range
45-400 Hz
Output Relay
Normally de-energized
Contact Rating
AC: 400 V, 5 A, 2000 VA; DC: 150 V, 5 A, 150 W
Overall Accuracy
±5%
±1%
Repeatability
Operating Temperature –20°C to + 70°C
Dielectric Test 2500 V, 50 Hz
EMC
CE according to EN50081-1, EN50082-1,
EN50081-2, EN50082-2
Approvals
Certified by major marine classification societies
Burn-in
50 hours before final test
Enclosure Material
Polycarbonate. Flame retardant
Weight
0.5 kg
DimensionsH 70 mm (2.76”); W 100 mm (3.94”);
D 115 mm (4.52”)
Installation
35 mm DIN rail or 4 mm (3/16”) screws
www.BDTIC.com/littelfuse
© 2013 Littelfuse Protection Relays & Controls
Littelfuse.com/t2400
Rev: 4-A-050213