Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Tecomat Foxtrot & INELS Description, Components, Applications 1 Suite of HW products Tecomat Foxtrot Important features: • High performance • Modularity • Installation module „circuit-breaker” design • Two-wire „free” I/O topology • Connectivity of CIB components • Number of I/O up to 134 + I/O CIB elements • Ethernet, Web server • On-line programming • SW backup • OPC server • Slot for MMC card for secondary memory • MODBUS, PROFIBUS DP, CAN Tecomat Foxtrot – small powerful modular PLC system for a wide range of small-size to medium-size applications in industry and building. Inels – intelligent electrical system for building applications using CIB bus. 2 Tecomat Foxtrot – description 3 Tecomat Foxtrot – modules 4 Tecomat Foxtrot – communication Ethernet 5 Tecomat Foxtrot – Communication modes Channel CH1 • • • • • • Mode PC Mode PLC Mode UNI Mode MPC Mode MDB Mode PFB - communication with superior systems through the EPSNET protocol - data sharing among PLCs in the EPSNET-F network - common channel with arbitrary asynchronous communication - data exchange with subordinated PLCs in the EPSNET multimaster network - communication with superior systems through the MODBUS protocol - master for the connection of stations PROFIBUS DP slave Channel CH2 • • • • • • • • • • • • Mode PC Mode PLC Mode UNI Mode MPC Mode MDB Mode PFB Mode UPD Mode DPS Mode CAN Mode CAS Mode CAB Mode CSJ - communication with superior systems through the EPSNET protocol - data sharing among PLCs in the EPSNET-F network - common channel with arbitrary asynchronous communication - data exchange with subordinated PLCs in the EPSNET multimaster network - communication with superior systems through the MODBUS protocol - master for the connection of stations PROFIBUS DP slave - operation of special submodules - realization of station PROFIBUS DP slave - connection of stations on the CANopen bus - realization of station CANopen - connection of the CAN bus -connection of CAN interface with SJA1000 driver Ethernet ETH1 • Mode PC • Mode PLC - communication with superior systems through the EPSNET UDP protocol in TCP/IP networks - data sharing among the PLCs in the TCP/IP network 6 Tecomat Foxtrot – controlling with I/O Energy monitoring Direct controlling energy sources and consumption (IRC systems] Process optimization. All standard PLC functions, fast inputs for counters, incremental position encoders, measurement of pulse length, period and phase shift. 7 What is an intelligent electro installation system? System of sensors and actuators which are situated on one bus and connected to control system. They work as remote I/O. 8 RS232 INELS 24V DC TCL2 FOXTROT = communication + I/O Ethernet 10/100baseTX UTP Optional interface/ for submodule MR • Communication part – at the left part – Ethernet 10/100 (RJ45) – CH1-RS232 UART up to 340kbit/s – CH2 – optional for 1 submodule – RS232 - MR0104 – RS482 – RS422 – 1xCAN – 2xCAN – Profibus DP slave – …LON atd. – Expansion by peripherals I/O modules Bus TCL2 – Expansion INELS - Installation elements – Power supplying 24V/DC 9 FOXTROT = communication + I/O • FI0..FI3 CP-1004 AI0…AI3 DI0……………..….DI7 RO0………………RO5 Basic I/O – at the right – INPUTS - basic functions • 8x DI 24V DC (DI0-DI7) – INPUTS - alternative functions • DI4-DI7 = analog AI0-AI3 – 0-10V – 10bit, – bez GO • DI0-DI3 = special functions FI0-FI3 – Fast counter, – Incremental sensor – OUTPUTS • 6x DO/RO, – Switching /NO/ contact relay – 230V AC/3A Optical indication 10 FOXTROT = basic types of I/O FI0..FI3 AI0…AI3 SPI0..SPI3 DI0……………..….DI7 DI0….DI3 RO0………………RO5 CP -1004 4 4 DI/FI DI/AI 6M 6 0 RO AO DI4……………..….DI11 IB -1301 12 DI 0 RO 3M FI0..FI3 DO0..DO3 DI0….DI3 DO4……………DO11 RO0………………RO7 0S -1401 0 AI 0 DI 0 AO 12 DO 3M 0 AI 0 AO AI0 IR -1501 4 0 DI/FI AI 3M 8 0 RO AO I D 11 R FOXTROT – modularity, connection • Module address 0-9 24V DC • System bus – – – – 345kbit/s BUS/RS485 200-300m Terminator is required – Basic module has to be at the left • Power supplying 24VDC Up to 300m 12 Bus installation units for the CIB bus • Individual work with remote I/O • Free topology – two wires • Mosaic libraries of function blocks for simple building installations – heating (air conditioning, ventilation), – illumination (dimming, time functions), – electronic alarm system functions – dim-out control, – … • For sophisticated technological applications in the field of building, source and heat distribution control. 13 FOXTROT is expandable by CIB elements 24V DC • CIB – – – – – • CIB MASTER – – • Data + Power supplying 2 wires Free topology 24V DC 32 units Next 2 buses 2x32 units CIB is suitable for building IRC (Individual room control) CIB – – – – – Lighting Heating Air-conditioning Alarm system … 230V AC 14 FOXTROT – Expansion of CIB buses CIB -1 9 x 32units = 288 units Power 230V AC/ 27.2V DC 288 x 14DI = 4032 DI = max. CIB-2 CIB-3 CIB-4 CIB-5 CIB-6 CIB-7 CIB-8 CIB-9 15 CIB works with safety voltage SELV 230V AC CIB 1 Power 230V AC/ 27.2V DC 4 kV 24V DC SELV 4 kV 16 RS485 INTEGRATION Ethernet Building Management System TECOMAT FOXTROT + CIB/INELS DIRECT CONTROL Intelligent Installation For control panels Room installation Interier components Acces control Security Fire signalization CCTV Video Electricity supply DDC/PLC Cooling DDC/PLC Heating DDC/PLC 17 Web server & client, File server • Embedded web server • It uses XML, which is more structured than HTML and doesn't spend the capacity of CPU. • Foxtrot uses file system on Flash disc, internal or on MMC/SD card Limitation is only the size of MMC/SD card 18 CIB Units - overview INELS BUS DI (DI), DO/RO AI Elements to installation box AO Special External Temperatur e sensor 8x DI IM2-80B 1x DI, 1x DO 1x RO LM2-11B SA2-01B 2x RO SA2-02B 4x 0-10V DAC2-04B/0 4x 1-10V DAC2-04B/1 2x dimming LM2-22B 4x 0-10V DAC2-04M/0 4x 1-10V DAC2-04M/1 2x dimming LBC2-02M DIN rail modules 1M, 3M 14x DI IM2-140M 2x DI, 2x DO DA2-22M 2x RO SA2-02M 4x RO SA2-04M Elements for interiors Voice Internal Temperatur e sensor ELEGANT Light Infra Button Infra 2 buttons WSB2-20 4 buttons WSB2-40 8 buttons WSB2-80 Analog/Digital thermostats IART2 SOPHY SOPHY L 19