Download Design training - Portal EMEA Gateway

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

CAN bus wikipedia , lookup

MIL-STD-1553 wikipedia , lookup

Power over Ethernet wikipedia , lookup

VMEbus wikipedia , lookup

Bus (computing) wikipedia , lookup

UniPro protocol stack wikipedia , lookup

Transcript
Tecomat Foxtrot & INELS
Description, Components,
Applications
1
Suite of HW products
Tecomat Foxtrot
Important features:
• High performance
• Modularity
• Installation module
„circuit-breaker” design
• Two-wire „free” I/O topology
• Connectivity of CIB components
• Number of I/O up to 134 + I/O CIB elements
• Ethernet, Web server
• On-line programming
• SW backup
• OPC server
• Slot for MMC card for secondary memory
• MODBUS, PROFIBUS DP, CAN
Tecomat Foxtrot – small
powerful modular PLC system
for a wide range of small-size
to medium-size applications in
industry and building.
Inels – intelligent electrical
system for building applications
using CIB bus.
2
Tecomat Foxtrot – description
3
Tecomat Foxtrot – modules
4
Tecomat Foxtrot – communication
Ethernet
5
Tecomat Foxtrot – Communication modes
Channel CH1
•
•
•
•
•
•
Mode PC
Mode PLC
Mode UNI
Mode MPC
Mode MDB
Mode PFB
- communication with superior systems through the EPSNET protocol
- data sharing among PLCs in the EPSNET-F network
- common channel with arbitrary asynchronous communication
- data exchange with subordinated PLCs in the EPSNET multimaster network
- communication with superior systems through the MODBUS protocol
- master for the connection of stations PROFIBUS DP slave
Channel CH2
•
•
•
•
•
•
•
•
•
•
•
•
Mode PC
Mode PLC
Mode UNI
Mode MPC
Mode MDB
Mode PFB
Mode UPD
Mode DPS
Mode CAN
Mode CAS
Mode CAB
Mode CSJ
- communication with superior systems through the EPSNET protocol
- data sharing among PLCs in the EPSNET-F network
- common channel with arbitrary asynchronous communication
- data exchange with subordinated PLCs in the EPSNET multimaster network
- communication with superior systems through the MODBUS protocol
- master for the connection of stations PROFIBUS DP slave
- operation of special submodules
- realization of station PROFIBUS DP slave
- connection of stations on the CANopen bus
- realization of station CANopen
- connection of the CAN bus
-connection of CAN interface with SJA1000 driver
Ethernet ETH1
•
Mode PC
•
Mode PLC
- communication with superior systems through the EPSNET UDP protocol in TCP/IP
networks
- data sharing among the PLCs in the TCP/IP network
6
Tecomat Foxtrot – controlling with I/O
Energy monitoring
Direct controlling energy sources and
consumption (IRC systems]
Process optimization.
All standard PLC functions,
fast inputs for counters,
incremental position encoders,
measurement of pulse length,
period and phase shift.
7
What is an intelligent
electro installation system?
System of sensors and actuators which are
situated on one bus and connected to
control system. They work as remote I/O.
8
RS232
INELS
24V DC
TCL2
FOXTROT = communication + I/O
Ethernet
10/100baseTX
UTP
Optional interface/
for submodule MR
•
Communication part – at the left part
– Ethernet 10/100 (RJ45)
– CH1-RS232
UART up to 340kbit/s
– CH2 – optional for 1 submodule
– RS232 - MR0104
– RS482
– RS422
– 1xCAN
– 2xCAN
– Profibus DP slave
– …LON atd.
– Expansion by peripherals I/O modules Bus TCL2
– Expansion INELS - Installation
elements
– Power supplying 24V/DC
9
FOXTROT = communication + I/O
•
FI0..FI3
CP-1004
AI0…AI3
DI0……………..….DI7
RO0………………RO5
Basic I/O – at the right
– INPUTS - basic functions
• 8x DI 24V DC (DI0-DI7)
– INPUTS - alternative functions
• DI4-DI7 = analog AI0-AI3
– 0-10V
– 10bit,
– bez GO
• DI0-DI3 = special functions FI0-FI3
– Fast counter,
– Incremental sensor
– OUTPUTS
• 6x DO/RO,
– Switching /NO/ contact relay
– 230V AC/3A
Optical indication
10
FOXTROT = basic types of I/O
FI0..FI3
AI0…AI3
SPI0..SPI3
DI0……………..….DI7
DI0….DI3
RO0………………RO5
CP -1004
4
4
DI/FI DI/AI
6M
6
0
RO
AO
DI4……………..….DI11
IB -1301
12
DI
0
RO
3M
FI0..FI3
DO0..DO3
DI0….DI3
DO4……………DO11
RO0………………RO7
0S -1401
0
AI
0
DI
0
AO
12
DO
3M
0
AI
0
AO
AI0
IR -1501
4
0
DI/FI AI
3M
8
0
RO
AO
I
D
11
R
FOXTROT – modularity, connection
• Module address
0-9
24V DC
• System bus
–
–
–
–
345kbit/s
BUS/RS485
200-300m
Terminator is
required
– Basic module
has to be at
the left
• Power supplying
24VDC
Up to 300m
12
Bus installation units for the CIB bus
•
Individual work with remote I/O
•
Free topology – two wires
•
Mosaic libraries of function blocks for simple
building installations
– heating (air conditioning, ventilation),
– illumination (dimming, time functions),
– electronic alarm system functions
– dim-out control,
– …
•
For sophisticated technological
applications in the field of building, source and
heat distribution control.
13
FOXTROT is expandable by CIB elements
24V DC
•
CIB
–
–
–
–
–
•
CIB MASTER
–
–
•
Data + Power
supplying
2 wires
Free topology
24V DC
32 units
Next 2 buses
2x32 units
CIB is suitable for
building IRC
(Individual room control)
CIB
–
–
–
–
–
Lighting
Heating
Air-conditioning
Alarm system
…
230V AC
14
FOXTROT – Expansion of CIB buses
CIB -1
9 x 32units = 288 units
Power
230V
AC/
27.2V
DC
288 x 14DI = 4032 DI = max.
CIB-2
CIB-3
CIB-4
CIB-5
CIB-6
CIB-7
CIB-8
CIB-9
15
CIB works with safety voltage SELV
230V AC
CIB 1
Power
230V
AC/
27.2V DC
4
kV
24V DC SELV
4
kV
16
RS485
INTEGRATION
Ethernet
Building Management System
TECOMAT FOXTROT + CIB/INELS
DIRECT CONTROL
Intelligent
Installation
For control
panels
Room
installation
Interier
components
Acces control
Security
Fire
signalization
CCTV
Video
Electricity supply DDC/PLC
Cooling DDC/PLC
Heating DDC/PLC
17
Web server & client, File server
• Embedded web server
• It uses XML, which is
more structured than HTML
and doesn't spend the
capacity of CPU.
• Foxtrot uses file system
on Flash disc, internal or on
MMC/SD card
Limitation is only the
size of MMC/SD card
18
CIB Units - overview
INELS BUS
DI
(DI), DO/RO
AI
Elements
to installation
box
AO
Special
External
Temperatur
e
sensor
8x DI
IM2-80B
1x DI, 1x DO 1x RO
LM2-11B
SA2-01B
2x RO
SA2-02B
4x 0-10V DAC2-04B/0
4x 1-10V DAC2-04B/1
2x dimming
LM2-22B
4x 0-10V DAC2-04M/0
4x 1-10V DAC2-04M/1
2x dimming
LBC2-02M
DIN rail
modules
1M, 3M
14x DI
IM2-140M
2x DI, 2x DO
DA2-22M
2x RO
SA2-02M
4x RO
SA2-04M
Elements for
interiors
Voice
Internal
Temperatur
e
sensor
ELEGANT
Light
Infra
Button
Infra
2 buttons
WSB2-20
4 buttons
WSB2-40
8 buttons
WSB2-80
Analog/Digital
thermostats IART2
SOPHY
SOPHY L
19