Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Systems Solution Centre Europe & Africa v2c – S&S EaA Internal 11-Apr-2006 The JC solution for small buildings and flat LON systems Johnson Controls confidential discussion draft. For internal use only One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Positioning • Demand on Small Systems Solutions is increasing • HVAC, Electrical, Fire, CCTV • Integration, Standard Protocols Support • Security or Alarm Monitoring or Fire Station • Some competitors offer simple solutions: • without network controllers • no need for web servers and applications • less performances versus a full BMS Johnson Controls confidential discussion draft. For internal use only 2 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 A solution for small buildings • Competitive, flexible and scalable solution to be proposed where no web access, demand limiting and interactions are requested • Simple solution when specifications or Customers are only considering SCADA oriented systems, including Fire&Security Supervision. • Based on M-Series graphic style • Serial connectivity N2 and MODBUS, BACnet MSTP via router to IP, LON, EIBus, M-Bus using gateways or direct link to PC • Available TCP/IP like MODBUS IP and BACnet over IP; others on request • IP tunnelling available on N2 and MODBUS Johnson Controls confidential discussion draft. For internal use only 3 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Features • Visualization and management for BMS and F&S • Graphic, Alarm, Trend • Read and write single and multiple points • Time stamp and report • Time Scheduler • Enhanced Notification (ESPA,SMS, SNMP) NO WEB, NO interaction, NO demand limiting! Johnson Controls confidential discussion draft. For internal use only 4 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Graphics M-Graphics • Base on M-Series • Graphic with animation • Status and command • Multiple commands • i.e. Zone Set point • Function Mode Command Johnson Controls confidential discussion draft. For internal use only 5 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Data Automation and Integration EDE (Extended Data Engine) • Core of M3i solution • N2 and MODBUS devices integration • OPC connection with data exchange (bridging) • Capability of simple processes Johnson Controls confidential discussion draft. For internal use only 6 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Extended Scheduler ESX • Enhanced Schedule Extension • Easy Scheduler tool creation • Send commands to JC and 3rd party devices • Multiple Command features Johnson Controls confidential discussion draft. For internal use only 7 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Alarms Handling M-Alarm • Alarm visualization for (HVAC, Electric, Fire, CCTV ACS and Intrusion) • Alarm tracking • Alarm acknowledgement Johnson Controls confidential discussion draft. For internal use only 8 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Collecting Trends M-Trend • Graphic and table Trend visualization • Multiple trend points • Zoom function for details Johnson Controls confidential discussion draft. For internal use only 9 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Option: The Reports Generator Metastore • Historical data report (temperature, humidity, pressure etc) energy consumption for energy management • Report on Quick-Report and Excel file (custom template); direct on printer local/network • Set up for report generation (daily, weekly, monthly); Johnson Controls confidential discussion draft. For internal use only 10 v2c – S&S EaA Internal 11-Apr-2006 Option: Advanced Notification One Company – One Team – One Goal SMS ANX • Message Management for Alarms to Analog & GSM modems • ESPA Protocol (es. PABX) • Messages tracking • Alarm Query Johnson Controls confidential discussion draft. For internal use only 11 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Option: Supervisioning simultaneous Screens Multiple screen • multiple SVGA video card • multiple screen : alarms, TVCC (Site Manager), topography and site maps Johnson Controls confidential discussion draft. For internal use only 12 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 N2 bus connectivity, System 9100, N2OPEN, MIG,VND and 3-party devices • DX9100, DC9100 • TC91xx, SC9100, XT9100, XTM105 • Facility Explorer line IU9100 N2 bus N2 bus XT/XP DX9100 • 3rd party Devices using N2 (VND) protocols • Configuration: MIG • Expandable to 4 serial bus trunks TC910x 3-party Emergency Remote I/O Operation Other Vendors Meter • MIG300 Integrator with all available drivers Variable Speed Drivers Extension Modules: Connectivity to other field buses, applicable when few devices or datapoints have to be reported on M3i Available for LONworks, Eibus, WILO, GRUNFOSS, KSB and M-bus Johnson Controls confidential discussion draft. For internal use only 13 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 N2 bus connectivity: FX devices IU9100 • FX Line devices • System 9100 devices • 3rd party Devices using N2 VND • MIG300 Integrator • Configuration: N2 bus Expandable to 4 serial bus trunks FX15 Master Display Master Controller FX15 FX15 FX15 FX05 FX14 FX05 MIG FX06 FX14 MIG FX06 Other Vendors Meter Meter Other Vendors Extension Modules: Connectivity to other field buses, applicable when few devices or datapoin have to be reported on M3i Available for LONworks, Eibus, WILO, GRUNFOSS, KSB and M-b Johnson Controls confidential discussion draft. For internal use only 14 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 N2 and MODBUS connectivity • All N2 devices IU9100 IU9100 N2 bus Modbus • MODBUS 3rd party devices (Chillers & Rooftop, PLC, Meters, Others) having same bus protocol (RTU or ASCII), same speed and unique addresses • N2 and MODBUS on separate buses XT/XP 3-party Emergency Remote I/O Operation Multimeter MIG FX06 Other Vendors Multimeter 3-party Emergency Remote I/O Variable Speed Drivers DX9100 PLC Variable Speed Drivers Extension Modules: Connectivity to other field buses, applicable when few devices or datapoints have to be reported on M3i Available for LONworks, Eibus, WILO, GRUNFOSS, KSB and M-bus Johnson Controls confidential discussion draft. For internal use only 15 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 N2E (DX9121) connectivity • N2 devices • N2E devices: max 20 DX 9121 per INT-DX-LON01 IU9100 N2 bus XT/XP INT-DX-LON01 DX9100 DX9121 MIG 3-party Emergency Remote I/O Operation DX9121 FX06 Other Vendors Variable Speed Drivers DX9121 Multimeter 3-party Emergency Remote I/O Operation Johnson Controls confidential discussion draft. For internal use only 16 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 The appropriate SCADA-like Workstation for LonWorks (A simple network using MIP interface, 5000 SNVTs) FTT10 LonWorks - Meter Fan Split Systems LON + IRC Solution PLC LN product line This version allows connection to devices having MIP interface (up to 4096 variables SNVTs) like VRV systems, PLC, LON gateways FTT10 network with repeaters and FTT/FTT routers are supported. LNS Binding Tool is needed (it has not to be a LNS Turbo Edition Version) LOnworks devices plug-ins can be used at OWS level Johnson Controls confidential discussion draft. For internal use only 17 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 The appropriate SCADA-like Workstation for LonWorks (VNI interface, LNS Turbo Edition, 5000 or 32000 SNVTs) It allows connection to devices having MIP interface (up to 4096 variables SNVTs) like VRV systems, PLC, LON gateways Zone Display FTT10 LonWorks (*) Router - Meter + IRC Solution Fan Split Systems LON LN product line Zone Display FTT10 LonWorks (*) Router - FX06 Other LONWORKS Compatible devices + IRC Solution Variable Speed Drivers PLC FX15 (*) TCP-IP/FTT10 Routing is supported. A LNS TE server and binding tool is required LOnworks devices plug-ins can be used at OWS level Johnson Controls confidential discussion draft. For internal use only 18 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 The appropriate SCADA-like Workstation for LonWorks M3i LN the appropriate SCADA-like OWS for LN series Zone Display FTT10 LonWorks (*) Router Zone Display (*) FTT10 LonWorks Router (*) TCP-IP/FTT10 Routing is supported. A LNS TE server and binding tool is required LOnworks devices plug-ins can be used at OWS level Johnson Controls confidential discussion draft. For internal use only 19 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 M3i LN Workstation and FX devices using LON Facility Explorer FX devices equipped with LON card Zone Display FTT10 LonWorks Router FX06 FX15 FX15 FTT10 LonWorks FX14 LON Meter Zone Display Router FX06 FX15 FX15 Johnson Controls confidential discussion draft. For internal use only FX14 LON Meter 20 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 M-bus connectivity – Energy metering RS232 M-Bus converter N2 bus • RS232- M-bus converters to link large amount of M-bus devices (max 255 per bus) • N2 M-Bus modules connecting up to 8 meters • MIG to have a share distributed devices • Metastore can be used to generate Custom reports • Expandable to 4 serial bus for N2 and /or MODBUS • Heat meters as N2 devices are available and covering the billing needs MIG N2 to M-bus RS232 to M-bus any M-Bus Meter Up to 8 M-Bus Meter any M-Bus Meter Johnson Controls confidential discussion draft. For internal use only 21 N2 RS485 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 EIB/KNX connectivity – Electrical points & Lighting • RS232/EIB interface or IP/EIB interface. • N2-EIB modules are usable in case of need with particular reference to small points or distributed EIBus networks • Various EIB solutions for lightings may be applicable using JC IRC devices IU9100 Ethernet TCP/IP EIB EIB EIB devices properly configured in the EIB network Johnson Controls confidential discussion draft. For internal use only EIB devices properly configured in the EIB network 22 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Fire connectivity • FIRE Panel FIRE Panel Johnson Controls confidential discussion draft. For internal use only • Esser IFC-8000 • Notifier AM-6000 • Data point automatically configured from Fire Panel database files to optimize commissioning time. • Other connections on request, the next are • Notifier Other Panels • Schrack • Any other available on SIS Europe list Serial or Ethernet Integrations N2 + MODBUS Fire: 23 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Intrusion connectivity • Intrusion: • • • CCTV : • Intrusion Pelco MATRIX CM6800 • Data point automatically configured from Intrusion Panel database files to optimize commissioning time. • • • Other connections on request, Any other available on SIS Europe list Planned DVN connection Integrations N2 + MODBUS Serial or Ethernet Aritech MASTER ATS Ademco Galaxy Intrusion Johnson Controls confidential discussion draft. For internal use only 24 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 BACnet connectivity • System integration as: MSTP Over IP P2000 Thick Client P2000 ACS • Split Systems (VRV, VRF,..) • Equipment (chillers, meters,.) • PLCs • Fire panels • Competitors • Others… Fan Split Systems BACnet IP • BACnet connectivity must be validated by SIS Europe • BACnet validated routers planned in FY06 Q3. Field Bus connectivit y • Fan Coils,HVAC Meters Variable Speed Drivers Other 3-party controllers Johnson Controls confidential discussion draft. For internal use only 25 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 P2000 connectivity details using BACnet IP • P2000 Alarms and Events - M3i OWS can receive P2000 alarms and events, allowing the workstation operator to acknowledge them. During an alarm, the Metasys system can perform a pre-defined action (e.g. the system turns on the lights to a room if a door open alarm has been reported for that area). • Access Hardware and Status Information - P2000 hardware configuration and status information can be accessed from an M3i. • Create Action Interlocks - The P2000 software can be configured to cause actions to occur within the Metasys system when access is granted. • Door Commands and Output Points - The Metasys M3i workstation operator has the ability to initiate a door-open command or trigger a security output point, all managed from a single seat operation. Johnson Controls confidential discussion draft. For internal use only 26 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Tunneling Connectivity TCP/IP Network • JC N2 Ethernet devices • MODBUS TCP/IP 3rd party devices connection • Needs a converter RS485/Ethernet for the BUS Ethernet Modbus TCP/IP XT/XP (LANTRONIX UDS-10, JCI SECVT,...) PLC DX9100 MS-SECVT-0 MIG Serial Integration LANTRONIX UDS-10 TC910x Fire Intrusion Multimeter CCTV Johnson Controls confidential discussion draft. For internal use only 27 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 IT management connectivity • Using ANX PABX • SMS to mobile, • ESPA to PABX • SNMP to NMS “trap” from UPS ESPA Ethernet SNMP SMS TRAP SNMP SMS=Short Messages ESPA=European Selective Paging Association Serial Integration PABX=Private Automatic Branch Exchange UPS Johnson Controls confidential discussion draft. For internal use only SNMP=Simple Network Management Protocol 28 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Future connectivity Future Connections or Special Applications • According with Release to Sales Note • Contact SIS Europe which can provide several solutions • Available MIG integrations can be moved to M3i platform, contact SIS Europe Johnson Controls confidential discussion draft. For internal use only 29 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 System Capability (standard configuration limits to be applied, for projects with different needs, please contact SIS Europe) BUS N2 Up to 100 N2 Devices Example: Max 80 TC91xx/FX06 Max 20 others DX91xx/FX15 MIG300 VND (ex. IME) BUS MODBUS Up to 100 MODBUS Devices Example : 10 Circuit Breaker 2 PLC 78 Multimeters 10 CDZ Liebert Hiross BUS Intrusion More devices with the same protocol. Example : MAX 8 Aritech ATS MASTER or 8 ADEMCO Galaxy MAX 4 connections, MAX 5000 mappable items points BUS Fire More devices with the same protocol Example : Max 8 Fire Centrals o Up to 5000 detectors Ethernet TCP/IP More devices with different protocol(Tunnelling) Example : 5 plc MODBUS TCP/IP 1 Aritech ATS Master Central 1 PELCO CCTV Johnson Controls confidential discussion draft. For internal use only LON Up to 100 device Lonworks devices, 5000 TAGs (SNVT’s) Flat LON, 32000 Tags, LON network design skills are required. BACNet IP Up to 4000 objects 30 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Networked Workstations Ethernet TCP-IP IU9100 IU9100 N2 bus INT-DX-LON01 DX9100 DX9121 XT/XP MIG DX9121 FX06 • Up to 4 Workstations • Field busses can be connected to each OWS, having access from each Workstation to each bus trunk meter DX9121 Other Vendors 3-party Emergency Remote I/O Operation 3-party Emergency Remote I/O Operation Johnson Controls confidential discussion draft. For internal use only 31 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Touch Screen as Workstation Ethernet TCP/IP M3i running on PC Panel Touch Screen Display having various sizes and fully localizable. All connectivity's available as per standard M3i on PC RS485 N2 bus XT/XP DX9100 Touch screens are in evaluation and test. Availability planned end FY06 Q4. SSC Europe to announce the Touch Panel products range in separate deployment, support and coordination activity. MIG TC910x Meter Other Vendors 3-party Emergency Remote I/O Operation Johnson Controls confidential discussion draft. For internal use only 32 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Touch Screen as HMI (Human Machine Interface) M3i connecting Local HMI Touch Screens having N2, Eibus and/or Modbus (various sizes, display types and fully localizable). Touchscreen are under evaluation and test, availability planned end FY06 Q4. SSC Europe to announce the Touch Panel products range in separate deployment, support and coordination activity. Ethernet TCP-IP RS485 N2bus XT/XP RS485 N2 bus RS485 Modbus DX9100 KNX EIbus 3-party Emergency Remote I/O Operation Meter MIG RS485 N2bus” XT/XP FX15 EIB Multimeter MIG TC910x FX06 3-party Emergency Remote I/O Operation Other Vendors Meter PLC Eibus Lighting or I/O system Other Vendors Meter Extension Modules Connectivity to other field buses, applicable when few devices or datapoints have to be reported to M3i. Available for LONworks, Eibus, WILO, GRUNFOSS, KSB and M-bus Johnson Controls confidential discussion draft. For internal use only 33 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Interaction with other systems • Links to documents as PDF, excel,…..) • P2000 • Via BACnet,reading status and doors alarm and send command of manual open doors • Using Internet Explorer (P2000 V.3.4) it’s possible manage and insert new account (Web Based) • Fire IFC-8000 • Alarm and trouble sensors, • Get the status of the central Johnson Controls confidential discussion draft. For internal use only 34 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Interaction with other systems • ARITECH ATS MASTER or ADEMCO GALAXY • • Alarm receiving and sensor trouble detection • Area and central status • It’s allows the partial &/or total insertion of the protection and the alarm reset PELCO MATRIX CM6800 • Visualization on TVC or monitor • Different sequence selection • To do the camera Preset on Dome devices • Interaction between Intrusion and TVCC using PC Johnson Controls confidential discussion draft. For internal use only 35 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Interaction with other systems • JC DVN Series • Ethernet connection • From Graphics map clicking on TV Camera: a pop-up with the image will appear • To alarm the DVN is needed an direct interaction with the antintrusion central Johnson Controls confidential discussion draft. For internal use only 36 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Interaction with other systems • In case : • • • No HW (hardwired) interaction No field device interactions No PC h24 controlled • When interaction is a critical M3i mission, UPS is strongly suggested. • Peer to peer communication at field level could be an alternative solution (LON, EIB, Modbus over IP, BACnet,....) Johnson Controls confidential discussion draft. For internal use only 37 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 EDE Sharing value + calculation MIG TC-9102 PLC Integration with VCT Johnson Controls confidential discussion draft. For internal use only 38 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 EDE Calculation Engine: Sources calculation EDE operators EDE Function EDE can combine multiple sources in a single equation using mathematical operators and functions. Available sources are, OPC/DDE Tags and field Network variables/Items. Equations does not allow managing runtime calculations, load shedding or load rolling. All these applications should be managed by field devices like DX9100 for runtime calculation. Johnson Controls confidential discussion draft. For internal use only 39 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 EDE calculation Engine EDE is able to send calculation value to multiple destinations and assign each destination a different value using equations with mathematical operators and functions. Available sources are, OPC/DDE Tags and field Network variables/Items. Equations does not allow managing runtime calculations, load shedding or load rolling. All these applications should be managed by field devices like DX9100 for runtime calculation. @ = Source Equation result. Johnson Controls confidential discussion draft. For internal use only 40 One Company – One Team – One Goal v2c – S&S EaA Internal 11-Apr-2006 Considerations Questions & Answers THANKS ! Johnson Controls confidential discussion draft. For internal use only 41