Download LenSx ® Laser SoftFit ™ Patient Interface

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Rhytidectomy wikipedia , lookup

Buttock augmentation wikipedia , lookup

Transcript
LenSx® Laser
Continuum of Innovation
October 2012
LSX12184SK | October 2012 |
a Novartis company
LenSx® Laser Important Safety Information
Caution:
United States Federal Law restricts this device to sale and use by or on the
order of a physician or licensed eye care practitioner.
Attention:
Reference the Directions for Use labeling for a complete listing of
indications, warnings and precautions.
Indication:
The LenSx® Laser is indicated for use in patients undergoing cataract surgery
for removal of the crystalline lens. Intended uses in cataract surgery include
anterior capsulotomy, phacofragmentation, and the creation of single plane and
multi-plane arc cuts/incisions in the cornea, each of which may be performed
either individually or consecutively during the same procedure.
Warnings:
The LenSx® Laser System should only be operated by a physician
trained in its use. The LenSx® Laser delivery system employs one
sterile disposable LenSx® Laser Patient Interface consisting of an
applanation lens and suction ring. The Patient Interface is intended for
single use only. The disposables used in conjunction with ALCON®
instrument products constitute a complete surgical system. Use of
disposables other than those manufactured by Alcon may affect
system performance and create potential hazards. The physician
should base patient selection criteria on professional experience,
published literature, and educational courses. Adult patients should be
scheduled to undergo cataract extraction.
Restrictions:
• Patients must be able to lie flat and motionless in a supine position.
• Patient must be able to understand and give an informed consent.
• Patients must be able to tolerate local or topical anesthesia.
• Patients with elevated IOP should use topical steroids only under close
medical supervision.
Contraindications:
• Corneal disease that precludes applanation of the cornea or transmission of
laser light at 1030nm wavelength
• Descemetocele with impending corneal rupture
• Presence of blood or other material in the anterior chamber
• Poorly dilating pupil, such that the iris is not peripheral to the intended
diameter for the capsulotomy
• Conditions which would cause inadequate clearance between the intended
capsulotomy depth and the endothelium (applicable to capsulotomy only)
• Previous corneal incisions that might provide a potential space into which the
gas produced by the procedure can escape
• Corneal thickness requirements that are beyond the range of the system
• Corneal opacity that would interfere with the laser beam
• Hypotony, glaucoma, or the presence of a corneal implant
• Residual, recurrent, active ocular or eyelid disease, including any corneal
abnormality (for example, recurrent corneal erosion, severe basement
membrane disease)
• This device is not intended for use in pediatric surgery
• A history of lens with zonular instability.
• Any contraindication to cataract or keratoplasty surgery.
LSX12184SK – A I October 2012
Precautions:
• Do not use cell phones or pagers of any kind in the same room as the
LenSx® Laser.
• Discard used Patient Interfaces as medical waste.
AEs/Complications:
• Capsulotomy, phacofragmentation, or cut or incision decentration
• Incomplete or interrupted capsulotomy, fragmentation, or corneal
incision procedure
• Capsular tear
• Corneal abrasion or defect
• Pain
• Infection
• Bleeding
• Damage to intraocular structures
• Anterior chamber fluid leakage, anterior
chamber collapse
• Elevated pressure to the eye
LenSx® Laser: Continuum of Innovation
• Software
• Patient Interface (PI)
• Functionality
• Performance
LSX12184SK – A I October 2012
Continuum of Innovation: LenSx® Laser 2012
 Modified Patient Interface
 Narrower cone apex, easier docking
 19.8 mm diameter
 Software 2.16: Precision, Automation & Flexibility
 HD OCT, 2x Resolution
 Advanced Automation
 Procedure pattern overlays
 Supports Bi-Manual technique
 Faster overall procedure
• Surgical Performance Improvement
– Better capsulotomy and lens fragmentation
LSX12184SK – A I October 2012
Product Requirements
• The LenSx® SoftFit™
Patient Interface Delivers:
 Lower IOP
 Easier docking
 Patient comfort
 Free floating capsulotomy
in nearly all cases
 Pristine cut edges
LSX12184SK – A I October 2012
A Simple Solution
• Proprietary soft contact lens insert
LenSx®
SoftFit™ Insert
LSX12184SK – A I October 2012
Alcon® LenSx® Laser SoftFit™ Patient Interface
• Current PI Design with extended suction skirt
• Proprietary soft contact lens insert
• Lower IOP – 16 mm Hg increase*
• Simple docking process – better eye control, no fogging
• Improved surgical performance*
LSX12184SK – A I October 2012
*LenSx® Laser Directions for Use
New LenSx® Laser SoftFit™ Patient Interface: Reduces
Corneal Compression & IOP to 16 mmHg Over Baseline
LSX12184SK – A I October 2012
NEW CAPSULOTOMY PERFORMANCE
Insert
Insert Video
Video
LSX12184SK – A I October 2012
New LenSx® Laser SoftFit™ Patient Interface
Eliminatescorneal
cornealcompression
compression in nearly all cases
• • Eliminates
LowersIOP
IOP––16mmHg
16mmHgincrease
increase
• • Lowers
Bettervisibility
visibilityw/w/no
nofogging
fogging
• • Better
Improvesdocking
dockingand
andcentration
centration
• • Improves
Fixatescornea,
cornea,no
noeye
eyemovement
movementfor
forprecision
precisionincisions
incisions
• • Fixates
Improved surgical
performance
• • Dramatically
improves
surgical performance
Noliquid
liquidrequired………
required………
• • No
LSX12184SK – A I October 2012
LenSx® Laser SoftFit™ Patient Interface
•
New Alcon® LenSx® Laser PI with proprietary soft contact lens technology
allows the natural curvature of the cornea to conform to a soft contact lens
insert delivering a gentle, secure fit with minimal corneal distortion.
•
New PI retains all of the features of our single piece curved patient interface
and provides additional benefits.
– Easier docking
– Lower IOP – 16 mmHg increase (over baseline)
– Enhanced Patient comfort
– Free floating capsulotomy in nearly all cases
– Pristine capsulotomy edge
LSX12184SK – A I October 2012
a Novartis company
© 2012 Novartis
10-12
LSX12184SK-A