Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Faster-than-light neutrino anomaly wikipedia , lookup
Future Circular Collider wikipedia , lookup
Antiproton Decelerator wikipedia , lookup
Weakly-interacting massive particles wikipedia , lookup
Super-Kamiokande wikipedia , lookup
ATLAS experiment wikipedia , lookup
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group Layout • PID in ALICE in the current design • Physics needs • Current studies – Simulations of the Belle design – Simulations of the integrating box design (Phenix) – Preliminary test beam results for the WLS readout of aerogel type (Novosibirsk) November 30.2004 Aerogel threshold detector for ALICE 2 ALICE LAYOUT: PID HMPID: High Momentum Particle Identification (, K, p) • RICH • Hard Probes TOF PID (K,p,) November 30.2004 -0.9<<0.9 Aerogel threshold detector for ALICE 3 ALICE hadron PID today • , K, p identified in large acceptance (2 * 1.8 units ) via a combination of dE/dx in Si and TPC and TOF from ~100 MeV to 2 (p/K) - 3.5 (K/p) GeV/c •In small acceptance HMPID extends PID to ~5 GeV /K TPC + ITS (dE/dx) K/p ? e / /K e / TOF K/p /K HMPID K/p (RICH) 0 1 2 3 4 5 p (GeV/c) The new results from RHIC point out for a serious need to extend the PID range especially for protons November 30.2004 Aerogel threshold detector for ALICE 4 Reasons to increase the momentum range of the PID • The present situations @ RHIC has strongly increased the need for PID @large momenta • The jet quenching has not resulted in an adequate increase of the low momentum multiplicities • The interesting range for protons is well above 5 GeV/c • At LHC one may estimate that the interesting range will up to 10-12 GeV for protons November 30.2004 Aerogel threshold detector for ALICE 5 The baryon puzzle at RHIC • where does the large proton over pion ratio at high pt come from? • why do protons not exhibit the same suppression as pions? fragmentation yields Np/Nπ<<1 fragmentation starts with a single fast parton: energy loss affects pions and protons in the same way! November 30.2004 Aerogel threshold detector for ALICE 6 Jet-Quenching: Primer What is a jet? leading particle What happens if partons traverse a high energy density colored leading medium? particle suppressed hadrons hadrons q q q q hadrons hadrons leading particle suppressed leading particle fragmentation of hard • partons can lose energy and/or scattered partons into fragment differently than in the vacuum collimated “jets” of hadrons November 30.2004 Aerogel threshold detector for ALICE 7 The case for aerogel threshold detectors • Due to the space constraints in ALICE the only conceivable extension of the PID is the use of threshold Cherenkov detectors with aerogel. • Currently studying three basic designs – The “Belle” design – The integrating box design – The WLS November 30.2004 Aerogel threshold detector for ALICE 8 Belle type – Collect scattered photons • Non-directional lights • Area of photocathode/cell size http://utkhii.px.tsukuba.ac.jp/~highpt/ November 30.2004 Aerogel threshold detector for ALICE 9 Simulation of the “Belle” design • Ingredients of the simulation: – Treatment of the Raileigh scattering – 98% reflection from the walls November 30.2004 Aerogel threshold detector for ALICE 10 One photon Full event November 30.2004 Aerogel threshold detector for ALICE 11 Number of photoelectrons in function of impact for the Belle configuration Good agreement with exp results at n=1.017 With 2 PMT we can reach ~15 p.e/event November 30.2004 Aerogel threshold detector for ALICE 12 integrating box design Advantage – possibility to use only one PM – not dependent on the coordinate of the impact Integration Sphere Aerogel November 30.2004 Aerogel threshold detector for ALICE 13 Results for the integrating box design N=1.008 November 30.2004 Aerogel threshold detector for ALICE 14 Summary I • The Belle type with two PMTs gives ~ 50% light more compared to the integrating box November 30.2004 Aerogel threshold detector for ALICE 15 Study of the aerogel thickness & variation with n With one PMT operation at 1.005 still possible November 30.2004 Aerogel threshold detector for ALICE 16 Alternative design A. Onuchin, A. Shamov, Yu. Skovpen and A. VorobiovA. Danilyuk, T. Gorodetskaya and V. Kuznetsov NIM 315, 1992, 517 Test made in October 2004 at the CERN PS WLS readout of the aerogel • Al container with sizes of 56 x 56 x 310 mm, • total volume of Aerogel ~ 0.5 liters •multi-layer Tetratex PTFE UV-film reflector, • WLS - Plexiglas plates ( 3 x 10 x 250 mm ) doped with BBQ • plastic light-guide • micro-channel plates (MCP) PMT with multi-alkali photocathode of 18 mm dia November 30.2004 Aerogel threshold detector for ALICE 17 Preliminary results • 7 GeV negative beam at CERN PS • Possibility to trigger out of the WLS • • • Efficiency n = 1.008 -- 65-70% n= 1.05 -- 99 • Number of photoelectrons n= 1.008 --<N>= 1-2 photoelectrons = 1.008 n= 1.008 --<N>= 1-2 photoelectrons Comparison with the simulations of the integrating box. The number of photoelctrons is much smaller but: Smaller photo detector by a factor 4 To be investigated the contribution to contamination by WLS. November 30.2004 Aerogel threshold detector for ALICE 18 November 30.2004 Aerogel threshold detector for ALICE 19 November 30.2004 Aerogel threshold detector for ALICE 20 Summary II • Possibilities of light output increase. – • • • • • • The ratio of signals from 1.05 and 1.008 are in agreement with the ratio of intensities of Cherenkov light from radiators of given indices. – the KEDR detector use the same aerogel (n=1.05) as was tested in our experiment. – Having the same quality of WLS and better MCP PMTs we could increase light output from proposed counters by a factor of 203/69=2.94. The length of WLS used in our prototype is 250 mm, KEDR ASHIPH counter – 500 mm. We expect the light attenuation in our shifters could be smaller by a factor of 1.3-1.4. The design of our counter gives the possibility to increase thickness of aerogel from 200 mm to 250 mm and more (additional factor of 1.25) Using the existing technology the light output could be increased by a factor of 5. The further possibilities are: PMT with AsGa photocathode of 30-40 % quantum efficiency (MCP PMTs we use have multialcali photocathode with mean QE=22%) November 30.2004 Aerogel threshold detector for ALICE 21 Where to place the VHMPID ALICE HMPID Charged particles multiplicity: ~ 80 m-2 Interaction rate: 104 (3% central events) PID: 1 < p < 3 GeV/c p K 2 < p < 5 GeV/c p November 30.2004 Aerogel threshold detector for ALICE 22