Module I Computed Tomography Physics, Instrumentation, and Imaging Disclaimer This workforce solution was funded by a grant awarded under the President’s Community-Based Job Training Grants as implemented by the U.S. Department of Labor’s Employment and Training Administration. The solution was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any information on linked sites and including, but not limited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, continued availability, or ownership. This solution is copyrighted by the institution that created it. Internal use by an organization and/or personal use by an individual for non-commercial purposes is permissible. All other uses require the prior authorization of the copyright owner. CT Artifacts and Quality control Seeram’s definition: “a distortion or error in (on) an image that is unrelated to the subject being studied”. CT Artifacts include: Foreign objects Breathing motion Peristalsis Cardiac motion Inaccurate Hounsfield numbers Equipment artifacts (electronics and mechanics or algorithms) Production artifacts Data Correction Processes Calibration procedures Pre and post patient operations …………have significantly reduced the occurrence of artifacts related to the CT imaging process. CT Artifacts Classification is related to the cause and appearance of the artifact. Streaks Shading Rings Bands cone Streak Artifacts Most common classification of artifacts manifested in CT. Causes: Improper sampling of data because of beam hardening Edge-gradient effect Equipment malfunction Metal objects Partial volume averaging Patient motion Beam Hardening Occurs when there is an increase in the mean energy of the x-ray beam as it attenuates through the patient. Low energy photons are absorbed, leaving high energy photons striking the detectors. Also called “cupping” Image taken from Seeram’s text page 192 Edge-gradient Artifacts CT system is unable to transfer information from the area of interest accurately due to large differences in atomic numbers of adjacent structures. ie: barium / air Appear as straight thin black streaks Equipment-induced artifacts Poor gantry rigidity Mechanical misalignment Radiographic tube rotor wobble Inadequate sampling of the detector signals Corrupt detectors can produce: Streaks Ring artifacts Streak Artifacts Metal inside scan area In some instances the gantry can be tilted to avoid streak artifacts which can not be removed. MAR – (Metal Artifact Reduction) software program which assists in the reconstruction through interpolation. MAR – (Metal Artifact Reduction) The raw data is acquired and stored The CT image is reconstructed Rough tracing of the prosthesis (metal implant) with a light pen is performed Automatic definition of the borders of the prosthesis within the projection data is performed. Using ROI threshold values Linear Interpolation is performed Reconstruction of the artifact reduced image from the new computed projection data is accomplished Partial Volume Averaging Occurs when a voxel is occupied by more than one type of tissue. The different tissues therefore can cause the area to be averaged. Partial volume averaging can cause partial volume artifacts (bands and streaks) – Can be reduced by selecting thinner slices and using (VAR) volume artifact reduction technique software. VAR Works by taking the different types of tissue within a voxel and dividing the tissues into thinner slices with a table incrimination between each. Data sets of the raw data are averaged to produce a composite thicker slice that will be free of the partial volume artifact. Illustration and more information on beam hardening and partial volume artifact can be found on pages 192-193 in the Seeram’s 2nd edition text. Patient Motion Voluntary and Involuntary – Use positioning aids such as pillows, sponges, myelogram straps. – Make your patient comfortable before beginning the exam. – Shorter scan times – Explain the exam to the patient – Motion software – Illustration for MAC (Motion Artifact Correction) can be found on page 189, Figure 11.22, Seeram’s 2nd edition text. Sampling Errors Sampling errors cause streak artifacts. Sampling errors are called Aliasing. Nyquist Theorem Sampling must occur at least twice the spatial frequency of the object scanned. Shading – Can be the result of: Partial volume averaging Beam hardening Spiral scanning Scatter radiation Off focal radiation Incomplete projection profiles Cone Artifact – Results when interpolation is not successful. – Image appears elliptical instead of round – The cone artifact can represent as two crescent-shaped bands of increased density Figure 2b Medicamundi, Volume 43, Issue 1, March 1999 Figure 2c Medicamundi, Volume 43, Issue 1, March 1999 Noise Produced from an insufficient number of x-ray photons striking the detectors. Can appear as graininess or streaks Can be caused from: Poor centering of the patient within the gantry Incorrect selection of exposure factors Aperture size Quality Control Tests Daily, Monthly, or yearly depending on the type of test. Must be done to produce high quality diagnostic scans. The scanner must be performing at optimal levels to insure the accuracy of the images and Hounsfield numbers. Some QC tests are done by the technologist and some are performed by engineers during PM (preventive maintenance). 3 Basic Components of Quality Control 1. 2. 3. Quality control must be performed on a regular, periodic basis. Prompt interpretation of QC test measurements. Faithful and meticulous record keeping. Daily QC Tests 1. 2. Average CT number in water Standard deviation of CT numbers in water CT Testing Phantoms CT scanners should never be sold without providing the QC phantoms for regular quality control measures. FDA – Department of Public Health – Office of Radiation Control