Download  

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power inverter wikipedia , lookup

Islanding wikipedia , lookup

Power engineering wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Ohm's law wikipedia , lookup

Transistor wikipedia , lookup

Rectifier wikipedia , lookup

Distribution management system wikipedia , lookup

Three-phase electric power wikipedia , lookup

Voltage regulator wikipedia , lookup

Transmission tower wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electrical substation wikipedia , lookup

Television standards conversion wikipedia , lookup

Surge protector wikipedia , lookup

Current source wikipedia , lookup

Voltage optimisation wikipedia , lookup

Stray voltage wikipedia , lookup

History of electric power transmission wikipedia , lookup

Alternating current wikipedia , lookup

Rectiverter wikipedia , lookup

Power MOSFET wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Opto-isolator wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Buck converter wikipedia , lookup

High-voltage direct current wikipedia , lookup

HVDC converter wikipedia , lookup

Transcript
CA‐NLH‐013 BDE to Western Avalon Line Page 1 of 1 1 Q. The Maritime HVDC Link was recently awarded, July 9, 2014, using voltage source 2 converters in a bipolar configuration. The converters will be connected to an HVDC 3 overhead line, an HVDC underground cable and an HVDC submarine cable, a very 4 similar configuration planned for the Labrador Island Link. Would the use of voltage 5 source converters for the LIL have an impact on the study results and possibly the 6 justification of the new 230kV transmission line? 7 8 9 A. Preliminary investigations have been performed to investigate the application of 10 Voltage Source Converter (VSC) technology for the Labrador ‐ Island Link (LIL) as 11 discussed in Hydro's response to PUB‐NLH‐056. The studies included a review of 12 system performance with respect to ac and dc contingencies. However, it has been 13 determined that the application of VSC technology is not technically feasible for the 14 LIL due to the current limitations of the insulated gate bipolar transistors (IGBTs). 15 The current limitations are such that the required overload rating of 2571 A per 16 pole would not be possible. Without this overload rating, the capacity of the bipole 17 would be limited due to instability following disturbances involving the loss of a 18 pole. 19 20 Based on the above, a line‐commutated converter technology has been chosen for 21 the LIL.