The I2 Air Fluid method for the elimination of bio-fouling in heat exchangers. The Problem Heat exchangers are the heart of any cooling system found in industry. They are found in many different industries and in many different configurations and styles. Their purpose is to transfer the heat from the warm water coming from a cooling apparatus; chiller or air conditioner, to the cool water coming from a heat dissipater; geothermal well or cooling tower. This is achieved by having concurrent streams run through conduits that are side by side and separated by thin metal walls. As the warm water from the cooling mechanism comes in contact with the metal wall separating it from the cooling water from the dissipater it transfers its heat through the metal and into the cooling water where it is dissipated into either the atmosphere or diffusion well. Heat exchanger efficiency and integrity is reduced when the plates are covered by bio film. This gelatinous film causes a reduction in heat transfer through; Occluded space which increases temperature and pressure through decreased flow within the geothermal or cooling tower side of the heat exchanger. Thermal insulating matter on the plates impedes heat transfer. Pitting corrosion on plate surfaces reduces plate heat transfer coefficient. This increases temperature within the coolant water to the chiller. Heat transfer Temp. Heat transfer Temp. Temp. Temp. Flow Flow Corrosion caused by bacteria. Heat transfer Heat transfer Inlet PSI Inlet PSI The APF protocol is used to clean the interior surfaces of the heat exchanger of existing bio-film. It is a once a month procedure that requires approx. one hour per month labor time and no disassembly of the exchanger. It consists of: Voiding the exchanger of any standing water within the exchanger through the introduction of air using the APF manifold. Introducing the I2 AFI cleaning solution. Allow for continuous agitation. Liquefaction of bio-film. Removal of cleaning solutions. Start of normal water flow The I2 infused air molecule eliminates free floating bacteria and bacteria resident in existing biolms. The bacteria is destroyed. Iodine is drawn into the cell and key amino acids in the respiratory chain are broken down. The cell wall is exposed continually to new low dose iodine within the air bubbles. Throughout the month, the plate walls are continually bathe in low dose I2 bubbles which keep bio-films from forming in a few ways. Turbulent bubbles lift and dislodge biofilm. Iodine liquefies biofilm. Bubbles prevent planktonic bacteria from adhering to plate surface. The continual profusion of I2 infused bubbles keep the plates clean, heat transfer at optimum and then continue on to the diffusion well screens and cooling towers where bio-film is eliminated at those sites. The results! Heat exchanger after 8 months of protocol. Diffusion well screens after 8 months? “Hi Mike, We have been running one 300 GPM supply well. We have left all 3 diffusion wells open. Each diffusion well has a capacity of 300 GPM. In order to determine if all 3 diffusion wells are working properly, we turned two off at a time so that we tested each diffusion well by itself to ensure that it was taking 300 GPM. All 3 took the 300 GPM of water without increases in incoming or outgoing pressure at the heat exchanger. I took that to mean that all 3 diffusion wells are working properly.”