Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
CERTIFICATE This is to certify that the project work entitled “Different Power Plants“ Is being submitted by Name of the student : Patel Akshaykumar V Shaikh Shahrukh Tiwari Brijesh Pandey Nitesh Enroll no.: 130330111026 130330111043 130330111048 130330111025 For fulfillment of requirements of semester-III of the degree Bachelor of Engineering ELECTRONICS AND COMMUNICATION at GUJARAT TECHNOLOGICAL UNIVERSITY For academic year 2014-15 Thermal Power Plants Steam Power Plants THERMAL POWER PLANT A Thermal Power Plant converts the heat energy of coal into electrical energy. Coal is burnt in a boiler which converts water into steam. The expansion of steam in turbine produces mechanical power which drives the alternator coupled to the turbine.Thermal Power Plants contribute maximum to the generation of Power for any country Thermal Power Plants constitute 75.43% of the total installed captive and non-captive power generation in India In thermal generating stations coal, oil, natural gas etc. are employed as primary sources of energy. Coal handling plant Pulverizing plant Draft fans Boiler Ash handling plant Turbine Condenser Cooling towers and ponds Feed water heater Economizer Superheated and Reheated Air preheated Coal Handling Plant Raw Coal Wagon- Coal is brought to the site through a Wagon as per requirement. Wagon tippler-The coal is unloaded from the Wagon and is transported to crushers and for storage place through conveyor. Junction tower- JT’s are used where the conveyor has any angular deviation. Rejected- The stones and unwanted coal is rejected Primary Crusher-The Raw coal is crushed into fine pieces to 45mm grit). Primary crusher is also called Rotary Breaker since the coal is crushed by a rotating plate. Secondary Crusher-The fine pieces of coal is crushed to powder (to 25mm grit) Two way conveyor Junction Tower Stacker & Reclaimer- It is used to store the powdered coal for emergency purpose Mill Bunker-The 25mm grit coal is crushed into very fine powder for feeding the boiler. We will have a spare Bunker for each Boiler. BOILER Atmospheric air (Through FD fan) The boiler is fed with HFO and LDO initially to ignite the coal in the Boiler. Types of boilers: 1. Water tube Boiler: A boiler in which water circulates in tubes heated externally by the fire. 2. Fire tube Boiler: Water is present in the drum inside the boiler and Hot air is circulated around maintain the temperature. Fuel HFO,LDO & Coal Air Boiler Fuel HFO,LDO & Coal Air Dryer •The fuel and air are feed from 2 increase the efficiency directions to Air compressor FD Fan Atmospheric Air The circulation of air is caused by a difference in pressure, known as Draft. Draft is a differential pressure b/w atmosphere and inside the boiler. It is necessary to cause the flow of gases through boiler setting It may be – 1. 2. Natural draft Mechanical draft Flue Gases The Ash from the boiler is collected in two forms: 1. Bottom Ash(Slurry):It’s a waste which is dumped into a Ash Pond 2. Fly ash: Fly ash is separated from Flue Gases in ESP(Electro static Precipitator). Economizer : Reduces the temperature Boiler Bottom ash(wet ash) Ash Pond Fly Ash & Flue Gases Chimney Economizer Flue Gases ESP Fly ash Cylo Cement Factory In a Thermal Power Plant generally 3 turbines are used to increase the efficiency. High Pressure Turbine(HPT): The superheated steam is directly fed to this turbine to rotate it. Intermediate Pressure Turbine(IPT): The out put from the HPT is reheated in a reheated(RH) and used to rotate IPT . Low Pressure Turbine(LPT): The Exhausted steam from the IPT is directly fed to rotate the shaft of LPT. *All the turbines are connected to a single shaft which is connected to the Generator. Super Heater Steam Shaft HPT RH IPT LPT Steam Condenser Generator Steam after rotating steam turbine comes to condenser. Condenser refers here to the shell and tube heat exchanger (or surface condenser) installed at the outlet of every steam turbine in Thermal power stations of utility companies generally. o o o o o o A condenser needs huge quantity of water to condense the steam . Typically a 2000MW plant needs about 1500MGallon of water. Most plants use a closed cooling system where warm water coming from condenser is cooled and reused Small plants use spray ponds and medium and large plants use cooling towers. Cooling tower is a steel or concrete hyperbolic structure having a reservoir at the base for storage of cooled water Height of the cooling tower may be 150 m or so and diameter at the Advantages of heating water before feeding back to the boiler:- Feed water heating improves overall plant efficiency. b) The dissolved oxygen and carbon dioxide which would otherwise cause boiler corrosion are removed in feed water heater c) Thermal stresses due to cold water entering the boiler drum are avoided. d) Quantity of steam produced by the boiler is increased. e) Some other impurities carried by the steam and condensate, due to corrosion of boiler and condenser are precipitated outside the boiler a) Water in a Power Plant is used for 1. Production of Steam- for rotating turbine. 2. Cooling Purpose- For cooling of various equipment . Water is recycled and used for various purpose: Raw Water Conden ser Steam Purified DM water For cooling purpose 3% of water is wasted during this process. Appx 4 cubic mt water is lost /day/MW Water Cycle Reservoir Water Clarification Chlorification & Filtration DM Plant (Demineralized Plant) Auxiliary cooling Water (ACW) DMCW Demineralized cooling Water Various Equipment Various Equipment Boiler Steam DMCWP Condenser PHE water 25D 35D CT Cooling Water 25D 20D D-Degrees CWP-cooling water Pump PHE-Pre heat Exchange Cooling Tower CT Hot water CWP CWP CWP Cool water Dearator Hot Well The coal is brought and crushed to powder. This is feed to Boiler for producing heat In Boiler the water is converted to steam. In Super heater the moisture content is removed from the steam and that steam is called super heated steam The superheated steam rotates the shaft of the High pressure turbine The Exhausted steam is sent to preheater and the steam then rotates the Intermediate pressure(IP) Turbine The steam from the IP turbine is then feed to low pressure turbine. The turbine shaft is connected to the Generator, which produces Electric Power. The power generated is then Transmitted. The Synchronous Generator is used to Generate power by connecting the shaft of the Turbine to the shaft of the generator which cuts the magnetic flux producing Emf. The Generated Voltage will generally 11KV to 20 KV max. The Generated Voltage is stepped up by connecting Step up transformer and is transmitted and is also used for Auxiliary purposes . UAT 20Kv to 6.KV Bus Duct SYNCHRONOUS GENERATOR Generator Transformer 20KV to 400KV Unit Auxiliary Transformer: This transformer is used to step down the produced voltage and use for Auxiliary purpose. Steam Power Plant mechanical power is produced by a heat engine that transforms thermal energy (from combustion of a fuel) into rotational energy heat (generated in the furnace) is transmitted to the boiler where water forced into the boiler by the feed pump is converted into steam steam drives turbine blades shaft the efficiency of a steam turbine is limited by the maximum temperature of the steam produced and is not directly a function of the fuel used (for the same steam conditions, coal, nuclear and gas power plants all have the same theoretical efficiency) Operating pressure Boiler efficiency Steaming hours Heating surface Generating surface Superheated steam Operating pressure – the pressure at which the boiler is operated in service Boiler efficiency -the ratio between the thermal energy actually absorbed by water and the thermal energy available in fuel (80 – 90 %) Steaming hours -the time during which the boiler generates steam Heating surface -the total surface of all parts exposed to combustion gases (tubes, superheater, economiser) Generating surface - a part of the surface in which water is heated and steam is generated (tubes, drum) Superheated steam = saturated steam + more heat at constant pressure –> dry steam (to avoid damage to tubine blades) FURNACE BOILER SUPERHEATER TURBINE CONDENSER