http://waterheatertimer.org/Troubleshoot-Rheem-Tankless-water-heater.html Tankless Troubleshooting Manual Explanation: Fan Motor Current fault. Fan motor does not work properly. At a minimum check the following: 1. Ensure fan motor will turn freely. Motor will operate with a small amount of restriction. 2. Check fan motor for presence of moisture of condensation. 3. Check wiring harness to motor for damaged and/or loose connections. See and follow the same procedure as used in Error Code 61. Explanation: Combustion Fan failure. Fan motor does not work properly. At a minimum check the following: 5. 6. 7. 8. Ensure fan motor will turn freely. Motor will operate with a small amount of restriction. Check there is some volume of air from the flue outlet at the top of the heater. Check wiring harness to motor for damaged and/or loose connections. Check Molex connections of the PCB. No Does the Fan Motor have sufficient voltage? Does the Fan operate? No Replace Printed Circuit Board Yes The water heater appears to be normal. Attempt to operate again. Yes % Is there any pulse output from the Fan Motor? ' Replace Fan Assembly Yes + ( , / 0 . ( 0 ( % 1 $ * . ( + & - 2 % ( ( ' " % ! % No 61 " $ # ) Replace Printed Circuit Board &