Intelsteer Power Saver Install IntelSteer Power Saver Device • Competent Technician • Safety Precautions • Install and tune-up according to installation manual instructions Wiring Diagram 3 Phase Supply Optional Reversing Contactor. K2 K1 Contactor MotorOverload Semiconductor Fuses (if fitted). Bypass contactor L1 K3 L2 L3 Intersteer Power Saver U V W EARTH EARTH(Electrical Ground) Motor Control line Basic Connection 110V/230V Control Supply FAN (if fitted) stop 1 2 3 4 5 6 Start CONN5 1 2 3 4 5 6 overload CONN6 TT K1 1 2 3 4 RL1 operation relay RL2 Programmabl e relay CONN7A Powerboss Control Line Slip Ring Motor • • • • What is slip-ring motor? Why to use slip-ring motors? How to start slip-ring motors? Can we remove rotor resistance? Wiring Diagram 3 Phase Supply control line power supply stop Connection method for slip-ring motors start Motor Overload Semiconductor Fuses (If Fitted) overload Wiring terminal 1 Connect in 415V operation status 1 2 3 4 5 6 7 8 9 (FAN voltage) 110 or 230VAC FAN (If Fitted) CONN1 K1 L1 L2 L3 Intelsteer motor U V U D V E 1 2 3 4 5 6 CONN6 RL2 W W F Connection method for slip-ring motors CONN7A 1 2 3 4 Earth TT Control line Y / Connection • Time-counter should be at minimum value • What to do if correction failed? • Relay RL2 is set to be fault one Control line Y / connection Isolator TT K3 1 2 3 4 5 6 7 8 9 CONN1 L1 L2 L3 1 2 3 4 5 6 FAN(if fitted) Intelsteer motor 110 or U V W RL2 CONN7A 1 2 3 4 Earth K1 K3 CONN6 K2 Line U1 W2 W1 U2 V2 Motor Overload Earth (Electrica Ground) Intelsteer Power Saver Install IntelSter Power Saver Devices • Verify matching current voltage and horse power • Ensure the IntelSteer electronic fan has matching voltage requirements • Please contact the Suppliers if there are any questions • Please read the installation manuals carefully! Intelsteer Power Saver Install IntelSter Power Saver Scenario 1 • Protection shell for IntelSteer is IP20 – Must be used on the wall. Equip with sealed pipeline cabinet when it is over 75kW • For heat dispersion purpose, as a minimum requirements, 30kw or below must leave 100mm space. For 30kw or above must leave 150mm space. Intelsteer Power Saver Install IntelSter Power Saver Scenario 2 • If higher IP standards must be met, InstelSteer should be installed in extra pipe enclosure • Heat fan must be installed in the Pipe Ensure to ensure the operating temperature if under 45ºC for IntelSteer Intelsteer Power Saver Install IntelSter Power Saver Extra Accessories Needed • • • • Isolator Fuse Contactor Motor overload Intelsteer Power Saver Install IntelSter Power Saver Required Information • Application • • • • • - Pay attention to ultra-high inertial load Motor - Power - Voltage - Current - Electronic Motor Type Environment - IP Standards Intelsteer Power Saver Install IntelSter Power Saver Connections • Inspect original equipments • Follow the steps in the installation menu • The shorter the distance between the IntelSteer and the Electronic Motor, the better the result • Please contact us if there are any doubts or questions) Intelsteer Power Saver Install IntelSter Power Saver Control line • Inspect fan voltage • The control circuit should be separate from the main power source • Ground connection must be properly installed on IntelSteer • Add a coil buffer to the coil on the contactor Intelsteer Power Saver Install IntelSter Power Saver Power factor correction capacitor • In on case it is allowed to install a power factor correction capacitor to the output terminal of IntelSteer electric appliance • A power factor correction capacitor should be installed in the K1M power inlet and be controlled by a contactor Intelsteer Power Saver Hoops1 • Every 1 amp. can generate 3.6W electricity • Given the specification of IP54, electric fan is needed • Pay more attention to slip-ring motors • Power factor correction capacitor Intelsteer Power Saver Hoops 2 • Crane: The installation is forbidden • Pay attention to high inertial load • Some loads only generate maximal torque at zero rotate speed. This kind of application should not be started in a buffering start mode • Brake gear motors: Different power supply must be provided