IEEE PES PSRC – C17 Joint WG “Wind Plant Short Circuit Contributions” Turbine & Aggregate Plant Short Circuit Considerations with respect to Power System Protection ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Russell Patterson Travis Smith ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Outline • Wind Power Plant & Substation Designs • Overview of Five Wind Turbine types • Need for Protection based Wind Turbine models • Transmission Planning Software • Power System Protection software • 20% Wind by 2030, some concerns – 30,000 MW now, 300,000 in 20 years – System protection and Wide Area Coordination – Grounding systems and protection – FERC #661 Ride Through & Dynamic Models – Power Quality, Harmonic Resonance ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Wind Power Plants Designs • WPP plants range from single to hundreds of WTG’s • Collection systems consist of many miles of underground and over-head lines at p to 34.5 kV ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Wind Plant Substation Designs Wye – Wye - Delta ©2009 Delta - Wye Wye – Delta with Effective Grounding Transformer IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Wind Plant Interconnection Switchyards • Many Substation & Switchyard configurations connecting wind plants to the Grid • Often, due to time constraints, these get scaled down to Three Terminal Lines ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Overview of Five Different WTG types WTG comparisons to conventional generators: • Smaller and connected at Low or Medium Voltages • Machines are Asynchronous or Synchronous • Some Protective Relay functions have been incorporated into the WTG Control Systems • Usually proprietary and not easy to obtain • Main Overcurrent Protection is typically within the WTG LV or MV Circuit Breaker • All WTG’s have auxiliary power which can be significant over a large wind plant ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Type I – SCIG Wind Turbine Generator • Turbine is fixed to grid frequency • Generates with negative slip • Soft starter for reduced inrush • PFCC’s for IG reactive support • Locked-Rotor fault contribution ranging from 5pu to 6pu • Short circuit represented as voltage source in series with the direct axis sub-transient inductance, Xd” ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Type II – WRIG Wind Turbine Generator • Turbine is fixed to grid frequency • Generates with negative slip • Soft starter for reduced inrush • PFCC’s for IG reactive support • Locked-Rotor fault contribution ranging from 5pu to 6pu • When rotor is shorted by rotor resistance the short circuit is represented as voltage source in series with sub-transient Xd” •When rotor resistance is at maximum the representation includes rotor resistance ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Type III – DFAIG Wind Turbine Generator • Variable frequency excitation system for rotor circuit, FourQuadrant Converter adjusts rotor current and phase angle quickly • Back-to-Back converter exchanges power directly with the grid • Wide Speed Range, Real & Reactive Power Control • If crowbar is not active SC is limited to 1.1pu rated • If crowbar is active SC model is a voltage source in series with Xd”, locked rotor of around 5 to 6pu ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Type IV – Full Converter Wind Generator •Four-Quadrant full frequency converter • Turbine fixed to turbine side converter frequency • Real & Reactive Power Control • Short Circuit limited to 1.1pu rated power • Line side converter can only contribute positive sequence current ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Type V – Synchronous Wind Generator • Synchronous generator coupled with variable speed drive train and torque & speed controls, 4 to 6 pole designs • Shaft speed converted from variable to constant speed which is coupled to the generator • Synchronized with the grid frequency through sync-check relay, protection, & circuit breaker • AVR control of synchronizing system • Unbalanced short circuit representation depends on grounding of the generator, can range from no zero sequence to more than 3PH fault values ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Need for Protection based WTG models • ANSI Std., larger Induction Machines should be considered in short-circuit calculations • Wind plant Designers, Owners, and Consultants need Short Circuit Models of WTG for: • Sizing, Protection, & Coordination • Overhead and underground lines & cables • Buses, structures, grounding, etc… • Transformers • Circuit Breakers • Capacitor & Reactor Banks • Dynamic Reactive Compensation ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Transmission Planning Software • WTG’s models created for Planning Software: - PSLF, PSS/E, PSCAD, Others… - Contributors include: IEEE Standards, WECC, ERCOT, NREL, UWIG, Others, etc. • Planning models are needed but are “Planning” specific and do not offer much to the System Protection Engineer for performing system protection and coordination studies. • IEEE-421.5 is being used for WTG models ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Power System Protection Software • Short circuit models of WTG’s are necessary • WTG’s should be modeled and wrapped into larger Utility Power System & Protection models for use in future protection studies, relay coordination, and wide area coordination simulations • Some of the Protection Software Packages: CAPE, ASPEN, Easy-Power, SKM, CYMTCC, MilSoft Windmil, ETAP, EDSA, Transmission-2000, S&C Web-based Coordinaide, SIGRADE, etc… ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Power System Protection Software Opportunities exist with respect to the Planning software models as well as EMTP/ATP models • DOE Awarded SBIR Grant, Electrocon Intl. Created a program that would allow communication between PSS/E transient stability simulations with CAPE protective relays and zero sequence, for analyzing protection schemes in CAPE with dynamic network simulation results from PSS/E • Electrocon Intl. also created a similar communication link between ATP/EMTP ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Power System Protection Software Since PSS/E has the Generic Wind Turbine Library, developed by ERCOT, WECC, NREL • Research possibility of C17 WG contributions to a separate effort which may include working with CAPE, ASPEN, PSS/E, PSCAD, EMTP/ATP, etc.. • The integration of Planning & Protection Commercial Software Packages may be the ideal way to create and help maintain dynamic short circuit models for use in Protection software packages through IEEE ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group United States Wind Plants (Commissioned & New) • Current Wind Energy Rated Capacity is approximately 31,612 MW • DOE Vision is 20% Wind by 2030, approximately 300,000 MW ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group System Protection & Wide Area Coordination Short Circuit Models are needed for Protective Relay Studies. ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Grounding Systems and Protection Temporary Overvoltage Conditions during a SLGF on the collector circuit, before and after fault instance and breaker TRIP Transfer Trip is an option for fast clearing. Grounding Transformer ©2009 Breaker with Integral Grounding Switch IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group FERC #661 & Dynamic WTG Models Transmission connected Wind Plants are now required to ride through and recover from transmission level 3PH faults. System relay coordination & checking will be more precise with future software connections to PSS/E & EMTP WTG dynamic model results - High Side Transmission Fault Strong System Per-unit Voltage Per-unit Current Weak System Per-unit Voltage ©2009 Per-unit Current IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Power Quality • Harmonic Resonance can be an issue with vast underground XLPE cable systems, static capacitor banks at the substation, and sometimes PFCC in turbines. • Many Permutations… ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group Questions? ©2009 IEEE PSRC C17 “Short Circuit Contributions of Wind Plants” Joint Working Group