* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download LHC_IR_quads_Heaters
Buck converter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Ground (electricity) wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical substation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Power MOSFET wikipedia , lookup
Surge protector wikipedia , lookup
Rectiverter wikipedia , lookup
Alternating current wikipedia , lookup
Printed circuit board wikipedia , lookup
US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley LHC IR Quad Heaters US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Schematic of LHC Inner Triplet 4 IP x (2 Triplets/IP)=8 Circuits -Q1 and Q3 made by KEK, Q2 made by Fermilab. Q1 and Q3 opposite polarity of Q2. - “ FNAL” Q2 consists of two 5.5m magnets bussed in series and contained in a single cryostat - Series of 8 model magnets + one full scale prototype. Michael Lamm 2 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Quench Protection Test on Model Magnets Protection Parameters -Quench detection threshold 300-500 mV -Strip heaters provide primary protection NO EXTERNAL ENERGY EXTRACTION -Redundancy two circuits (H1&H3, H2&H4) -Simulate CERN Heater Circuit: 7 mF, 900 V voltage, RC~100mS, Peak Power >20 W/cm2 Magnet Protection Requirements: -Peak Temperature <400K -Peak Voltage to Ground <1000 V Heater Parameters: -Heater Insulation -Heater Width -Resistance Distribution -Heater Location Michael Lamm 3 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Magnet Position Element (all 25 m thick) Insulation HGQ01 Inter Stainless steel 15.9mm wide 325uM Outer None N/A Inter Stainless steel 15.9mm wide 325uM Outer Stainless steel 15.9mm wide 350uM Inter Outer Stainless steel 15.9mm wide 325uM 15.9 mm wide with copper plating 38 mm etched areas at 114 mm intervals. 350uM Inter None N/A Outer 12.7 mm wide with copper plating 610 mm etched areas at 1930 mm intervals. 250uM Inter None N/A Outer 22.2 mm wide with copper plating 610 mm etched areas at 1930 mm intervals. 250uM Inter None N/A Outer 15 mm wide with copper plating 120 mm etched areas at 360 mm intervals. 250uM HGQ02 HGQ03 & HGQ05 HGQ06 HGQ07 HGQ08 HGQ09 Inter Outer Michael Lamm None Quench protection program MQXB Location Outer coil 2 mm from midplane Material Copper plated stainless steel Copper thickness 4 m SS thickness 25 m Copper Plating 102 mm etched areas at 306 mm intervals Width 15 mm Insulation to Coil 225 m N/A 15 mm wide with copper plating 102 mm etched areas at 204 mm intervals. 225uM 4 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Two design Parameters: Heater Location and Distributed Resistance Inter Layer Vs. Outer Layer Inter Layer -Outer layer heaters are easier to install -Inter layer heaters might be more effective Longitudinal Resistance Distribution -Power supply specs are fixed, so..what is more important: larger area coverage or higher peak power? Michael Lamm Outer Layer 15 mm 9 mm 210 mm (with copper plating) 105 mm (without copper plating) .21 mm 5 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Using Quench Integral to Study Two Heater Parameters Quench Integral MIIT's 20.0 Inner vs.Outer Heaters 15.0 HGQ08 55 W/cm**2 HGQ09 22 W/cm**2 HGQ09 45 W/cm**2 HGQ08 22 W/cm**2 10.0 Longitudinal Resistance Distribution 5.0 0.0 0 0.2 0.4 0.6 0.8 1 I/Ic QI 10 6 I t2 t dt 10 6 0 1 T peak A2 T0 c pcomp T ' Cu T ' dT ' MIIts Outer heaters just as effective as inner Quench detection times significant part of quench integral Longitudinal resistance distribution works Michael Lamm 6 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Peak Temperature (use spot heaters that simulate spontaneous quenches) 300 Most pessimistic quench location tested with spot heater. Outer Pole Inner Pole 250 200 150 400 HGQ07 50 W/cm**2 100 HGQ08 50 W/cm**2 350 50 0 2 4 6 8 Current (kA) 10 Spot heater quenches in pole turn 12 14 Measured Peak Temperature (K) Measured Peak Temperature (K) 350 HGQ09 22 W/cm**2 300 HGQ09 45 W/cm**2 HGQ09 no. 2 45 W/cm**2 250 200 150 100 50 0 2.0 Michael Lamm 4.0 6.0 8.0 Current (kA) 10.0 12.0 14.0 7 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Voltage to Ground 120 Opposite heater circuit Adjacent heater circuit Peak Voltage (V) Stainless Steel Only Heater imbalanced heater geometry 80 40 0 2000 5000 8000 11000 The eight coils that make up a HGQ magnet are bussed in series, with inner to outer pole turn splice. Voltage to ground is largely due to resistive-inductive (im)balance between inner and outer coils 14000 Current (A) For 1.9 M model, voltage to ground is low, less than 30 Volts at peak operating field gradient... Michael Lamm 8 US LHC ACCELERATOR PROJECT brookhaven - fermilab - berkeley Protection Conclusions Heaters -Heaters adequately protection magnet from excessive peak temperatures and peak voltage to ground -Outer layer heaters are just as effective as interlayer heater. Outer layer heaters chosen for ease of installation -Reducing insulation doesn’t seem to have much effect (or small compared to other variables -Increasing peak power is more important than longitudinal resistance: use HGQ08 style heater Bus Work -Parameterize temperature and velocity -Single layer stabilizer is adequate. Opt for 1 layer of copper Michael Lamm 9