* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download HVSBstatus_02_09 - Indico
Standby power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power factor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power over Ethernet wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electric power system wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Rectiverter wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Power supply wikipedia , lookup
CALO HV Status bits for ODIN • Introduction Status bits of the LHCb readout supervisor ODIN • HVSB board specification • HVSB board block diagram • Board consideration • Planning of the board development and production LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 1 CALO HV Status bits for ODIN Introduction All calorimeter HV systems (ECAL-HCAL, PRS) are based on CW DC – DC convertors. The pumping middle voltages are produced by Agilent power supplies. The HV_LED_DAC boards distribute the 80 V power to ECAL and HCAL CW bases and PRS HV boards equipped with CW convertors are used the 150 V. The current consumption from middle voltage power depends of a HV value. For HV PHYSICS settings expected current consumption is about: • 3 mA per channel for PRS ; 0.3 A for one sub-detector side of 100 channels. • 0.5 mA per CW base for ECAL; 1.5 A for one sub-detector side of 3008 channels. • 0.6 mA per CW base for HCAL; 0.4 A for one sub-detector side of 744 channels. ECAL and HCAL MV power is distributed to a group of CW bases. From 16 to 40 bases in one group are powered by one line. Each power line has the over current protection relay that goes off when a current is over limit and after this the 100 V power supply current is changed on 10 – 35 mA. This estimation shows a needed sensitivity of a current monitoring circuitry that will be produced the HV Status bits for ODIN. In case if a part of the CW bases is OFF or the MV power supply current is high (near the current limit setting) we can set the ODIN status bit to ON (it will mean detector in Bad condition). Design of a simple electronics board for a power supply current measurement and transmission the status bits with needed levels to ODIN is under progress now. LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 2 CALO HV Status bits for ODIN to Electronics platform Barack D3 HCAL,ECAL,PRS 100 V SPECS RJ45 cable to control PC in D2 Power Supplies New electronics board “HV Status Board” (HVSB) Additional LV power supply for HVSB board SPECS Mezzanine 100 V power long distance cables to detectors HVSB board functionality: Fast measurement MV power supply currents. Produce the “warning” LVDS signal (one bit per sub-detector) to the ODIN in case when the power current is out of range. Board equipped with DAC, comparator and logic IC’s. LVDS RJ45 cables ODIN Rack with CALO MV Agilent Power Supplies The Specs mezzanine will be used for DC levels measurement by DCU-ADC and communication with ECS. Sketch of the possible implementation sending status bits to ODIN LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 3 CALO HV Status bits for ODIN Block diagram of HVSB board ECAL_A MV line I to V Converter ECAL_C MV line I to V Converter HCAL_A MV line I to V Converter HCAL_C MV line PRS_A MV line PRS_C MV line Logic FPGA ACTEL or ALTERA I to V Converter I to V Converter LVDS drivers to ODIN 12 comparators I to V Converter SPECS Bus Min 6 chan. DCU-ADC SPECS Mezzanine I2C bus Max level 12 DAC IC’s LHCb CALO meeting 4.02.09 Parallel Bus Status Indicators Anatoli Konoplyannikov [ ITEP / LAPP ] 4 CALO HV Status bits for ODIN Board consideration There is one open question concerning of the power supplies DC decoupling. There are two possibility. First one is connect the ground lines of the MV power supplies together or other one is use an opto-coupling technique for keeping the ground lines separated. In the first case an analog part of the HVSB board is much simple, but some tests will be needed for verifying EMC noise. In the second case an analog part is more complicated and linear optocoupled amplifier can be used. For example a linear Amplifiers the IL300 Optocoupler produced by Vishay Semiconductors could be used for implementation the current to voltage converter. Schematic of the linear optocoupled amplifier. Positive Unipolar Photovoltaic Amplifier LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 5 Detector HV Status bits for ODIN HVSB board consideration Mechanical implementation and board powering. Mechanical implementation of the HVSB board could be similar the HV_LED_DAC implementation with simple non standard mechanics. The board will be inserted into the rack with MV Agilent power supplies. The low voltage power supply (Agilent PS) will be placed under the HVSB board in the same rack (see sketch on slide 3). Status Indicators Specs RJ45 Drivers to ODIN 160 Sketch of the HVSB printed circuit board with main components placement SPECS Mezzanine Logic FPGA Analog Circuits LV Pwr Input/Output MV connectors 232 LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 6 CALO HV Status bits for ODIN Conclusion & Planning The possible solution of the CALO sub-detector status bit realization has been presented. The solution is based on the MV power supply current measurement. Together with Cyril perform an analog part simulation and prototype test of the HVSB board. Order needed electronic components. Start a board development using CADENCE software at CERN and LAPP. Develop firmware for control logic FPGA. Develop PVSS project for monitoring and control HVSB board. Develop a DIM server for an additional LV power supply and integrate power control into existing PVSS project. LHCb CALO meeting 4.02.09 Anatoli Konoplyannikov [ ITEP / LAPP ] 7