Communication Markets Division
965AMS Product Overview
© 3M 2007. All Rights Reserved.
Communication Markets Division
Outline








New Out-of-Box
965 Versions
Test Set Features
Operating the 965AMS
Capacitive Faults
Resistive Faults
Auto Tests
Fault Locating


RFL
TDR
2
© 3M 2007. All Rights Reserved.
Communication Markets Division
New Out of the Box
 965AMS
 AC/DC Adapter
 Carrying Case
 Power Cord
 Battery Pack
 Vehicle Charger
 Spare Battery Holder




 Test Leads
 Self Test Simulator
 Shorting Strap
3
© 3M 2007. All Rights Reserved.
USB Cord
Serial Adapter
Warranty Card
Instruction Manual
Communication Markets Division
965AMS Functions
Volts: Press
DC or AC.
Resistance: Press
Opens: Press
for Soak Test.
for Setup.
Selects T-R or R-G or T-G.
Loop Current:
Ground Resistance.
Toolbox: Stored results, Self
Calibrate, Ohms/distance, Internet
Explorer, Upload to PC LINK, 3M
Use and Available Options.
Tone: ID Tone (200 Hz to 1kHz,
Precision (200 Hz to 19,999 Hz) and
Wideband (20 kHz to 2.2 MHz).
Resistive Fault Locator: Measure
shorts, grounds and crosses with
single pair or separate pair
connections.
4
© 3M 2007. All Rights Reserved.
DSL Menu: DSL Loss, DSL Noise,
DSL Spectrum Analyzer,
Resistance Balance and Impulse
Noise.
TDR: Single Trace, Dual Trace,
Peak, Crosstalk, Differential, TDR
Memory, Memory Diff and Live Diff.
POTS Menu: Loss, Noise,
Longitudinal Balance, Load Coils,
Caller ID, Ringers, Level Trace,
Kick TestActive
and Voiceband
SA.
Autotest:
Pots, Vacant
Pots, Vacant Wideband.
Dial Key: Allows 965AMS to be
used as a Buttset or send DTMF
commands to a FED.
Module: Accesses the attached
module.
Communication Markets Division
Setup
 The welcome screen
displays the:
4.00.01

Serial
0537003T

Version
4.00.01
 The bottom of the screen
will indicate any function
keys that are available.
5
© 3M 2007. All Rights Reserved.
Communication Markets Division
Operating the 965AMS
Clip Colors
Battery Status
E
Function Name
1/2
F
Battery Life
8 Hours Continuous Use
Result
Function Soft Keys
6
© 3M 2007. All Rights Reserved.
Charging Time
Typically 4 Hours
Communication Markets Division
Turning the unit On/Off
Press the red
key to power up the unit or power
down the unit
There are two ways to power down the unit.
1.
Sleep mode – Quickly press and release the red
key. This is normal daily use.
2.
Cold Boot – Hold the red
key down for ten
seconds and then release. Use this mode when
the unit will not be used for an extended amount of
time.
7
© 3M 2007. All Rights Reserved.
Communication Markets Division
Contrast
8
© 3M 2007. All Rights Reserved.
Communication Markets Division
Setup
Country
Language
Module
Network Setup
Units
User Info
Clock Settings
Set Beep Volume
Power Down Timeout
Edit Custom Cable
Voltage Termination
9
© 3M 2007. All Rights Reserved.
 Setup allows you to change
a variety of settings.
 Use the up or down key to
navigate and then press the
F4 or F5 key to change.
Communication Markets Division
Clock Settings
10
© 3M 2007. All Rights Reserved.