* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PowerPoint 演示文稿
Pulse-width modulation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power inverter wikipedia , lookup
Control system wikipedia , lookup
Scattering parameters wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electric battery wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Two-port network wikipedia , lookup
Power dividers and directional couplers wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power electronics wikipedia , lookup
Mains electricity wikipedia , lookup
Buck converter wikipedia , lookup
Rechargeable battery wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Tuesday, May 23, 2017 Reliable Efficient Convenient Intelligent Huawei UPS5000-A Series Solution Content 1 UPS5000-A-400/500K Product Highlights 2 Products Introduce 3 Products Competitive Analysis 4 The Installation of UPS&optionals and Alarms List 1 Huawei UPS Series Large UPS8000-D 200-600kVA Medium UPS5000-A 30-800kVA UPS5000-E 40-320kVA Small UPS2000-G 1-20kVA Modular UPS RT Small Power UPS 2 Tower transformerless UPS Tower transformer-based UPS Product Overview Input three-phase and output three-phase, top/bottom outlet compatible, dimensions(H*W*D)2000*1200*850mm Easy installation-connecting power cables without removing the side panels and cabinets can be installed in parallel, top/bottom outlet compatible. High power density, 500K’s footprint is only 1m2. Wide input voltage range from 138 Vac to 485Vac, adapted to the harsh grid, stable and reliable. Efficiency up to 96%, significantly reducing loss by 50%. Output PF 0.95,at the same capacity UPS can load more. 3 UPS5000-A-400/500K Core Values—Reliable Wide input voltage and frequence range: 138-485V, 40Hz-70Hz, reducing the number of switching to battery mode, and avoiding a Verification and testing products' reliability in a full range Surge test high incidence; reducing the battery charge and discharge times, LLT TEST extending battery life Redundant design from the functional unit to the components, THB TEST Temperatur e cycle test including auxiliary power and the control unit, to prevent single point of failure Conformal Coating for adapting salt spray, dust ,high temperature and humidity , expanding the life-span of key Component and ensuring high reliability The cycle connection of parallel signal cables, to prevent the signal point of failure. 4 Key device bias test HALT TEST Unique Cross-material verification Wet dust test Long-term 14 weeks High temperature and humidity Sulfide dust UPS5000-A-400/500K Core Values—Efficient 96% 94% <85% Traditional UPS Brand E UPS5000-A High efficiency of 96%,the leader in the field, and up to 99% at ECO mode. 5000A UPS saves 51,643 kW·h per year for you (VS 200kW@94%) 5000A UPS saves 315,000 kW·h per year for you (VS 200kW@85%) 5 UPS5000-A-400/500K Core Values—Convenient High output PF up to 0.95, adapt to new IT load, significantly improve 0.15m the UPS’s load capacity Small footprint, 500K covers an area of 1m2, reduce customer investment Traditional Tower UPS 400kVA Huawei 500kVA UPS in room Adjustable battery number from 30 to 40, as a result, the backup time can 0.8m 1.2m be configured precisely and re-use of the battery. Standard SNMP and ModBus protocol, FE, RS485 and dry contacts, and other interfaces, easy networking and monitoring. 6 Savings covers 50% compared to other UPSs 0.85m UPS5000-A-400/500K Core Values—Intelligent NetEco Intelligent battery management extending battery life 50% above, include battery dormant, temperature compensation, intelligent float conversion. 网管中 Video System Cooling System Power Distribution System Network Management Center Supply neteco intelligent monitoring software, send the alarm to operation and maintenance personnel through SMS or e-mail , NetEco Server1 Access Control System NetEco Server n centralized intelligent UPS management. Modular Cluster LCD+Signal UPS Monitor Multiple UPS Network Management System SMS Alarm Engine room Terminal Remote Management Real-time monitoring Output report Pre-failure Assets management 7 Content 1 UPS5000-A-400/500K Product Highlights 2 Products Introduce 3 Products Competitive Analysis 4 The Installation of UPS&optionals and Alarms List 8 Functional components Number Functional components 1 Power unit 2 Control unit 3 Optional card slot 4 PDU Maintenance bypass switch Bypass unit 5 6 UPS5000-A’s main functional components: power unit, communication slot, control units, and control expansion options and monitoring bus which is in order to achieve multimachine monitoring and configuration, etc. 9 UPS5000-A Components Subsystem Component Function Power cabinet Performs AC-DC and DC-DC conversion on mains and battery inputs respectively, and boosts the voltage to the bus voltage. Then the inverter converts DC inputs into AC sine wave outputs. Power unit Power conversion. Bypass unit Provides bypass voltages when the power unit is abnormal or after you transfer the UPS5000-A to bypass mode. Power distribution unit (PDU) Provides input and output power distribution. Monitoring system Monitoring display unit (MDU) Provides a liquid crystal display (LCD) for human-machine interactions. Monitoring subrack Houses various monitoring units. Energy control module (ECM) Controls intra-rack and inter-rack system running, and reports status information to other monitoring units. Dry contact card Enables the UPS5000-A to manage the battery system, including the external battery switch and BMU. It also provides alarm signals for external devices and implements emergency power-off (EPO). Monitoring interface card Provides an external port for the MDU and provides some monitoring and control functions. Backfeed protection card (optional) Provides mains and bypass backfeed detection and protection. Dry contact extended card (optional) Provides five relay dry contact outputs and five signal inputs, delivering abundant alarm and control functions. 10 Components-ECM Number Control Components 1 BSC port 2 Parallel port 3 Run indicator 4 Alarm indicator 5 Fault indicator the running of a single UPS5000-A and parallel system, and reports the UPS5000-A status information to other monitoring units. Two ECMs in the monitoring system standard, to prevent a single point of failure。 Two Parallel ports and two BSC ports UPS5000-As parallel in cycle networking to prevent signal point of failure, which contains two Parallel ports and two BSC ports. 11 Components- Monitoring Interface Card NO. Port Silk Screen B_TEMP 1 Battery temperature sensor port 2 3 4 Southbound port 1 Southbound port 2 Network port COM1 COM2 FE 5 Northbound Communications port RS485 6 MDU port MDU DO_1_NO DO_1_COM DO_2_NO DO_2_ COM DO_3_NO DO_3_ COM DO_4_NO DO_4_ COM DO_1 DO_2 7 DO_3 DO_4 12 The monitoring interface card provides external ports for the MDU and certain monitoring and control functions. It provides ports for sensors, the BMU, the fast Ethernet (FE), and the NMS. Support NetEco monitoring software, can monitor up to 10 UPSs. Description Connects to an indoor battery temperature sensor Connects to an ambient temperature and humidity sensor over two wires. Connects to a southbound device, such as a BMU. FE port,support SNMP Connects to a northbound network management device or third-party network management device over two wires. DB26 contains FE、RS485、I2C、CAN, etc signals. DO indicates critical alarms, minor alarms, bypass mode, battery mode, low battery voltage, or D.G. control. DO_3 indicates any of the six meanings (except for D.G. control); by default, it indicates bypass mode. The maximum voltage is 30 V DC, and the maximum current is 1 A. Components- MDU Status On Off 1 Fault indicator Color Meaning Red A critical alarm has been generated. Yellow A minor alarm has been generated. Green The UPS5000-A is running properly. N/A The MDU has been powered off. 2 LCD screen Supports up to 2500 alarms history records to check 13 Components- Dry Contact Card Port J1 J2 J3 Description Port for detecting battery grounding faults. Connected: battery grounding fault. Port for detecting diesel generator (D.G.) mode. Connected: D.G. mode. the battery system (including the external Port for monitoring the battery switch. Connected: battery switch ON. Port for controlling the trip of the battery switch in the BCB box. battery switch), provide alarm signals for 12 V: battery switch tripped. Emergency power-off (EPO) port. The initial status is Disconnected. If external devices, and implement remote EPO. the normally open (NO) port is connected to the EPO_12V port, EPO. Disconnected: circuit breaker OFF. Port for monitoring the maintenance circuit breaker on the output PDC. Disconnected: circuit breaker ON. Port for monitoring the bypass input circuit breaker on the input PDC. J5 The dry contact card allows the UPS to manage Port for detecting the BCB box. Connected: BCB box connected. EPO port. The initial status is Connected. If the normally closed (NC) port is disconnected from the EPO_12V port, EPO is triggered. Port for monitoring the UPS output circuit breaker on the output PDC. J4 Disconnected: circuit breaker OFF. Port for monitoring the input AC surge protective device (SPD). Disconnected: SPD disabled 14 Functional description of each interface table on the right, for details, see the UPS user manual. Installation Top/Bottom Cable Routing, Mains input and Bypass input can share a power source or not. Top Cable Routing diagram Bottom Cable Routing diagram Mains and bypass use different sources Step1:Remove the copper bars Step2:Connect mains and bypass input cables respectively. 15 Content 1 UPS5000-A-400/500K Product Highlights 2 Products Introduce 3 Products Competitive Analysis 4 The Installation of UPS&optionals and Alarms List 16 UPS5000-A Specifications Type UPS5000-A-400K Capacity 400kVA/380kW UPS5000-A-500K 500kVA/475kW Input Main Input Rated input voltage Input voltage range Input system Rated frequency 380/400/415Vac 138-485Vac Three-phase, four-wire, and PE wire 50/60Hz Input frequency range 40-70Hz Input PF THDi Rated input voltage Bypass Input 0.99 ≤3% 380/400/415Vac Input frequency range 50/60±6Hz Input system Three-phase, four-wire, and PE wire 360-480 V DC (30-40 batteries, 32 by default). The UPS5000-A power is derated by 6% when 30 batteries are configured. Battery Battery voltage 17 Type Capacity Output Rated output voltage Frequency Output PF THDv Output system Efficiency Overload capability Environmental Specifications Operating temperature Storage temperature Humidity Altitude Noise Physical Specifications Dimensions (H x W x D) mm Weight Communication UPS5000-A-400K 400kVA/380kW UPS5000-A-500K 500kVA/475kW 380/400/415Vac±1% In normal mode, the mains frequency is synchronous with the bypass input frequency. The frequency is 50 Hz or 60 Hz (tolerance ±0.25%) (local frequency of the inverter). 0.95 THDv<1% Three-phase, four-wire, and PE wire 96% Inverter overload capability: 110%: transfer to bypass mode after 60 min; 125%: transfer to bypass mode after 10 min; 150%: transfer to bypass mode after 1min 0-40℃ -40-70℃ 0%-95%(non-condensing) 0-1000 m. When the altitude is above 1000 m, see IEC62040-3 to check how the UPS5000-A power is derated. The maximum altitude is 4000 m. <70dB 2000×1200×850 900kg 1000kg Dry contacts, RS485 port, and FE port supported; SNMP supported 18 Parameters compared E1 NXP Form Brand Type Input system Rated input voltage (Vac) MAIN Input voltage range(Vac) Input Input frequency(Hz) HUAWEI UPS5000-A-(200-600K) Three-phase, four-wire, and PE wire E1 NXP Three-phase, four-wire 380V/400V/415V(line voltage) 380/400/415 138-485 40Hz~70Hz -15%~+25% adjustable 50/60Hz±10% Input PF >0.99 0.99 THDi) <3%(full linear load); <5%(full non-linear load) <3% Output PF 0.95 0.9 <1%(full linear load) <4%(full non-linear load) <2%(full linear load), <5%(full non-linear load) Up to 96% 4 >99% 95.5% 6 99% Total harmonic distortion of output Voltage THDv Efficiency System Number of parallel UPSs ECO Efficiency Output 19 Parameters compared with A1 Galaxy7000 form Item UPS5000-A Galaxy7000 Input Voltage Range(V) 138-485 250-470 Input frequency Range (Hz) 40-70 45-66 Overload capability 125%:10min 150%:1min 125%:10min 150%:1min Output PF 0.95 0.9 Input PF 0.99 0.99 Efficiency 96% 94.3% Weight(kg) 500kVA: 1000kg 500kVA:1500kg 20 Parameters compared with E2 9395 Form Item UPS5000-A E2 9395 Input Voltage Range(V) 138-485 190-475 Input frequency Range (Hz) 40-70 45-65 Total harmonic distortion of output Voltage (THDv) <1%(full linear load) <4%(full non-linear load) full linear load 3%, full non-linear load 5% Input Power Factor(PF) 1 0.9 Efficiency Up to 96% Less than 95% Weight(kg) 600k-1100 600k-1450 125% transfer to bypass mode after 10 min 150% transfer to bypass mode after 1min <3%(full linear load); <5%(full non-linear load) 125%:10min; 150%:1min; <3% (100% full linear load); <5% (full non-linear load) Overload capability THDi 21 Content 1 UPS5000-A-400/500K Product Highlights 2 Products Introduce 3 Products Competitive Analysis 4 The Installation of UPS&optionals and Alarms List 22 Optional:Temperature Sensor Battery temperature sensor:Connect to the B_TEMP port on the monitoring interface card , monitors the ambient temperature near batteries, to achieve temperature compensation. Ambient temperature and humidity sensor:monitors the ambient temperature and humidity in the equipment room for the stable operation of the UPS. 23 Optional:Dry Contact Extended Card The dry contact extended card provides five relay output dry contacts and five input dry contacts. Monitor and control critical alarms, minor alarms, bypass mode, battery mode, low battery voltage, and diesel generator, etc. For details, see the UPS user manual. 24 Optional: Battery Monitor Unit Each BMU monitors a maximum of 24 batteries’s voltage, charge and discharge currents, and temperature. Users may need to configure two BMUs, n = 1 to 10, in each group can monitor the maximum 240 cells. Each BMU monitors a maximum of 24 batteries with a rated voltage of 2-12 V. BMU communicates with the UPS monitoring system that makes the installation and maintenance becomes very simple and quick. 25 Optional:Battery Grounding Failure Detector The battery grounding failure detector checks for current leakage on the battery loop and reports battery grounding failure signals to the uninterruptible power supply (UPS). 26 Installation of the Short-distance Battery Temperature Sensor Connect the short-distance battery temperature sensor to the B_TEMP port on the monitoring interface card on the UPS On the Communication screen, set NTC to Enabled 27 Installation of the Ambient Temperature and Humidity Sensor Configurations Set the DIP switch on the ambient temperature and humidity sensor. For details, see the user manual. On the LCD, choose System info. > Settings > Communication. The screen shown in Figure is displayed. 28 Installation of the Dry Contact Extended Card Remove the filler panel from the monitoring module 1 Remove the filler panel 2 Insert the card , Tighten screws The dry contact extended card supports hot swap. 29 Installation of Battery Monitor Unit 1 As figure shows the connections of battery and BMU 2 Connect power cables to the BMU Connect the N(+) port to the positive terminal of the external power supply, L(-) port to the negative terminal, and PE port to the protection ground cable. 4 Set BMUs On the liquid crystal display (LCD) Check all connections and turn on the power switch, set as the figure. For details, see the user manual. 30 3 Connect the UPS and BMU Connect an RS485 port on the BMU to the COM2 port on the UPS monitoring interface card. Installation of Battery Grounding Failure Detector As the figure to install the battery grounding failure detector, perform the following steps: 1 Remove the front panel. 2 Install the battery grounding failure detector on the UPS along the guide rail. 3 Place the fuse on the fuse base, and install the fuse base. 4 Connect the battery grounding failure detector to the UPS and AC current transformer. 5 Reinstall the front panel on the power distribution subrack, check and then power on . 31 Appendix: Alarm List 32 HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.