* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Slide 1
Induction motor wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Stepper motor wikipedia , lookup
Electrical substation wikipedia , lookup
Rectiverter wikipedia , lookup
Buck converter wikipedia , lookup
Control system wikipedia , lookup
Protective relay wikipedia , lookup
Logic Control What is Logic control • Logic control is a control based on a logic concept, that is the on-off state of variable and/or equipment • Logic control is often used to control combinational and/or sequential events such as lift control, automatic production line, engine start-up, etc. • Originally used device such as switches, relay, timer, drum, and any other mechanism to enable changes of the on-off state SWITCHES Toggle Hand Switches ~ Single pole single throw (SPST) Toggle Hand Switches ~ Single pole double throw SPDT switches Toggle Hand Switches DPST DPDT Hand Switches 3PST Rotary Swtich Push button Hand Switches Normally open NO Normally close NC Push-Push Switch • This looks like a momentary action push switch but it is a standard on-off switch: – push once to switch on, – push again to switch off. • This is called a latching action. Microswitch • usually SPDT • Microswitches are designed to switch fully open or closed in response to small movements. • They are available with levers and rollers attached. Keyswitch • A key operated switch. • The example shown is SPST. Reed Switch • Usually SPST • The contacts of a reed switch are closed by bringing a small magnet near the switch. • They are used in security circuits, for example to check that doors are closed. • Standard reed switches are SPST (simple on-off) but SPDT (changeover) versions are also available. • reed switches have a glass body which is easily broken! DIP Switch • DIP = Dual In-line Parallel • This is a set of miniature SPST on-off switches, the example shown has 8 switches. • The package is the same size as a standard DIL (Dual In-Line) integrated circuit. • This type of switch is used to set up circuits, e.g. setting the code of a remote control. Multi-pole Switch • The picture shows a 6pole double throw switch, also known as a 6-pole changeover switch. • It can be set to have momentary or latching action. • Latching action means it behaves as a push-push switch, push once for the first position, push again for the second position etc. Multi-way Switch • Multi-way switches have 3 or more conducting positions. They may have several poles (contact sets). A popular type has a rotary action and it is available with a range of contact arrangements from 1-pole 12-way to 4-pole 3 way. • The number of ways (switch positions) may be reduced by adjusting a stop under the fixing nut. For example if you need a 2-pole 5-way switch you can buy the 2-pole 6-way version and adjust the stop. Process Operated Switches • These switches is constructed using one of the above switches. A process variable will initiate a displacement to switch the switch – – – – – – – Limit switch Proximity switch Pressure switch Level switch Temperature switch Flow switch etc SWITCH CAPACITY • On a switch usually there is a label informing the voltage and current capacity, e.g.: 250 V 5A • It means that: – the maximum current allowed to pass the switch is 5 A. – The maximum voltage across its terminal allowed is 250 volt I<5 A ~ ~V<250 V RELAY Relay NC contact NO contact coil RELAY • A relay is an electrically operated switch. • Current flowing through the coil of the relay creates a magnetic field which attracts a lever and changes the switch contacts. • The coil current can be on or off so relays have two switch positions and they are double throw (changeover) switches. • Relay consist of coil and contact • Usually a relay has 1 coil and many contacts both NO and NC Relay Picture is downloaded from www.kpsec.freeuk.com/components/relay.htm Relay • • • • In electrical diagram relay is symbolized as shown A relay can have many contacts both NO and NC The coil of a relay typically passes 30mA for a 12V relay, The contacts can drive 5A or more depending on the size of relay contacts coil NO NO NO NO NC NC RELAY SYMBOL WITH 8 CONTACTS NC NC Relay 30 mA R12 R11 5A R1 12 V ~ 220V • Relays allow one circuit to switch a second circuit which can be completely separate from the first. • For example a low voltage battery circuit can use a relay to switch a 220V AC mains circuit. • There is no electrical connection inside the relay between the two circuits, the link is magnetic and mechanical. N Ladder diagram Ladder Diagram • To make such as previous diagram easier to read a ladder diagram is used + S R1 R11 Basic logic + AND LOGIC s1 s2 L Lamp L will light if switch s1 and s2 are on. In logic on usually symbolized as 1 and off as 0. s1 0 s2 0 L 0 0 1 0 1 0 0 1 1 1 Mathematically written as L = S1 AND S2 - Basic logic + OR LOGIC s1 L s2 Lamp L will light if switch s1 OR s2 are on. s1 0 s2 0 L 0 0 1 1 1 0 1 1 1 1 Mathematically written as L = S1 OR S2 - Basic logic NOT LOGIC + s1 R1 R11 L Lamp L will light if not R1 is on R1 0 L 1 1 0 Mathematically written as L = NOT(R1) - Combinational logic Suppose you want to design a safe car with the following criteria: The gear box (GB) will not engage unless: 1. The hand brake (HB) is released and the doors (D1-D4) are locked or 2. The safety system is disable by switching on override switch (OS) for maintenance purpose Mathematically the above logic is written as GB = (HB AND D1 AND D2 AND D3 AND D4) OR OS HB D1 D2 D3 D4 GB OS Motor Start Stop (sequential logic) • The following ladder diagram is used to switch a motor on and off S1 S2 R1 start stop R11 R12 R13 motor Latching action R14 Auto start of water pump • Suppose that the motor is used to drive water pump and we want that the pump can run or stop automatically depending on the water level • In addition we also want to override the automatic control using manual start and sop control LS Auto start of water pump • Off, manual and auto motor control O M A S2 S1 R1 start stop motor R11 LS Permissive circuits • Often it is desired that a piece of equipment is allowed to start if several conditions are met. • For example overload switch and over temperature switch must be closed in order the motor can be started • Each process condition is called a permissive, and each permissive switch contact is wired in series, so that if any one of them detects an unsafe condition, the circuit will be opened. Auto start of water pump with protection • Suppose we want to protect the motor against over load and over temperature Permissive circuits O M S0 A S2 S1 R1 start stop OL R11 LS motor OT Interlock circuits • Often it is desired that only one piece of equipment is allowed to start if all other equipments are in off condition. • For example push button circuit used in Quiz show program where several contestant have to answer a question. • The first one who pushes the push button will disable the other’s push button switch • This circuit is called interlock since acting one circuit will lock the others to function Push Button In Quiz Show program A B R12 R21 R11 R1 R2 LA R22 LB R13 R23 Push Button In Quiz Show program A R21 R31 B R11 R31 C R11 R21 R12 R12 R22 R13 R23 R33 R1 R2 R3 LA LB LC Push Button In Quiz Show program Instead of pushing the PB continually it is desired that just pushing once is enough for the contestant to claim that they are the first team pushing the button The presenter must push the reset button to reset the system back to original state Reset A R21 B R11 R1 R12 R2 R22 R13 R23 R13 R23 LA LB Interlock Another example of interlock is the forward circuit of motor must prevent the reverse circuit, otherwise the motor will damage Note: Motor contactor (or "starter") coils are typically designated by the letter "M" in ladder logic diagrams. Time delay relay • If the motor is carry a high inertia load it is dangerous to reverse the direction of the motor instantaneously. • Time delay relay can be installed to prevent such occurrence to happen Fail safe design • Consider an alarm system as shown. • It can be design in 2 ways • Both ways work exactly in the same manner • The second design however gives fail save design. • Murphy’s law is true. If something can go wrong it will.