Download No Slide Title

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
EWCM 41x0 family
New 32x74
Invensys Controls Europe
An Invensys Company
Product description
New compressors rack controller
Product architecture
 Panel mounting, case dimensions 32x74x75 mm (including cables)
 Case plastic in ABS, UL-94 V0;
 Power supply: 12 Vac 50/60 Hz;
 Removable connectors (outputs and inputs);
 RTC on board (for alarm history)
 Number of compressors adjustable by parameter (up to 4);
Advanced GUI
 4 digits LED display + 18 (colour) icons and leds to improve “easy to
use” Human Interface
Advanced control algorithms
 Historical data storage, inverter management, etc.
 Inverter Control of Compressors
 Inverter Control of Fans
Technical information
Technical information:
• Microprocessor:
• RAM:
• FLASH:
• COM1
8bit 14.7MHz
4 Kbyte SRAM
128 Kbyte
UART 1, TTL for local conn. or monitoring connection
I/O’s resources:
• 4 A.I.
• 5 D.I.
• 4 or 5 D.O.
• 0 or 1 triac onboard
• 1 or 2 pulse outputs
• 0 or 1 A.O.
2 temp. + 2 config. (NTC/V/I or D.I.)
all SELV (Safety Extra Low Voltage)
2A, 230Vac, SPST*
2A, 230Vac
SELV, V or I
Power supply:
• 12Vac +/-10%, 50/60Hz, no insulation provided
Physical layout
Panel Mounting Solution
75mm
Bus adapter
Copy Card
4120 connection schemes
4180 connection schemes
HMI: Display and Icons
Fan LED
Prog Menu
Alarm Icon
Heating mode
Cool Mode
set
Go into machine status menu
Access to subfolders
Set parameters value
5 secs pressure goes into Prog. menu
Display is Temperature (C/F)
Increase parameter value
Navigate through folders
5 secs pressure goes into band menu
Compressor ON
Decrease parameter value
Navigate through folder
5 secs pressure goes into setpoint menu
Exit from menues
5 secs pressure goes into a menu to select standard
visualization
Bar / Psi Display is pressure
Not configured LED (for future)
Compressors management. DIGITAL
•Can be used for homogeneous compressors up to 4;
•Higher is the distance from the set, higher is the number of step running;
•Start and stop values are calculated automatically dividing the band equal parts (=number of steps)
•Advanced policy on compressor management (Balancing / saturation / fixed sequence);
Compressors management. CONTINUOUS
•It’s a PROPORTIONAL control based on low pressure probe;
•Two Cut-Off function available (for minimum speed and for saturation);
Fans management.
•Uses proportional algorithm;
•In Chill mode can activate also “pre-ventilation” algorithm (fan speed at max before to turn on a
compressor);
Fans management. CONTINUOUS
• At every start-up fans will be forced to spin at max power;
• If pre-ventilation is on, before to turn a compressor on fans are forced at a maximum speed.
Advanced functions
The controller can be turned On/Off by:
•Keyboard;
•Digital input;
Working hours:
Thanks to the installed RTC system can record working hours;
Historical Alarm:
Thanks to the RTC the system can record the time of alarms;