MCS-TOUCHSCREENS
www.mcscontrols.com
MCS-TOUCH-7
FRONT
BACK
 NEW FOR 2015
 High Resolution (1280 x 800)
 LCD Display with LED Backlighting
MCS-TOUCH-15.4
FRONT
BACK
 ON-SCREEN KEYPAD
 MCS-CONNECT and
MCS-GRAPHICS provides
both graphics and service mode

The MCS-TOUCH-7 and TOUCH-15.4 are new
touchscreen interfaces designed to simplify user access
with the MCS-Magnum and MCS-MicroMag utilizing
MCS-Connect to provide both graphics and service mode
access to technicians.
 Information and graphics on the MCS-TOUCH-7 and
MCS-TOUCH-15.4 are shown on a high resolution
(1280x800) LCD display with LED backlighting, which
will guarantee long-life operation.
 The MCS-TOUCH-7 and 15.4 are suitable for
installation for both indoor and outdoor applications.
Utilizing a gasket for an environment seal provides the
unit with a NEMA 4 rating.
MCS-TOUCHSCREEN
MOTHERBOARD - FRONT
7in LCD
connector
4 GB EMMC
Flash Memory
15.4IN LCD
Connector
800 MHZ
i.MX6 ARM Micro
5 wire connection
15.4 Touchscreen
RTC
Battery
mPCIe
Expansion
slot
1 GB DDR3
Memory
MICRO
SD Slot
2 - USB
Ports 2.0
Ethernet
Port
4 wire connection
7in Touchscreen
Serial
Console
Port
3 - RS 485
Communication Ports
+12 V DC
Power Input
MCS-TOUCHSCREEN
MOTHERBOARD - BACK
1 USB Port
On-the-Go
INCLUDED COMPONENTS
12 VDC - 50W Single Output Power
Supply for Touchscreen
Resistant to short circuiting,
overloading and over voltage
Operating temperature up to 700C
Ethernet Crossover Cable
5ft CAT 5e Crossover Patch Cord
Orange
DESKTOP WITH COMPANY GRAPHIC
SETTING UP THE NETWORK
Click Options
to set Static &
Dynamic IP
address
Click the key shown and the
network manager will appear
as shown in this screen shot
Editing Wired Connection –
Static Address
Click
IP4 Settings
to change
Network Settings
Static IP, Netmask &
Gateway Address
Set to Manual
for Static IP or
Auto DHCP
for Dynamic
Click Add to add a
Static IP
Enter Static IP,
Netmask &
Gateway Address
Click to save
MCS-CONNECT SCREEN
Click Setup to move to
the MCS-CONNECT
setup screen
Click to display the MCS-CONNECT main screen
MCS-PC CONNECT Setup Screen
Local COM Port
Choose 1 to 4
COM PORTS:
RS485 1 = 1
RS485 2 = 2
RS485 3 = 3
USB-RS485 = 4
Click to save
OPENING THE ON-SCREEN
TOUCH KEYBOARD
Click this key to see on-screen Keyboard
DIRECTORY FOR MCS FOLDERS
Autostart boot config file
runs in background to
start MCS-CONNECT
Click this key to see MCS Folders
BOOT CONFIG FILE STARTING
MCS CONNECT
File shows MCS-TOUCHSCREEN Boot Config file starting MCS-CONNECT
GETTING TO THE MICRO CONTROL
WEBSITE SOFTWARE PAGE
Click this key to go to the MCS website for software updates

The MCS-TOUCH-7 and 15 makes it easy for the user to manage more
complex installation diagrams, without losing the overall view of the
installation, as well as ensuring that the pages can be browsed in a fast
and straightforward manner.

Photos below and on the next page are actual screen shots using
MCS-CONNECT and MCS-GRAPHICS.
MCS GRAPHICS
 The MCS-TOUCH-7 and 15.4 can connect to up
to 60 MCS Controllers at once and supports
RS485 or Ethernet networking.
MCS-TOUCH – CONNECTION
RS-485 TO ONE MCS-MAGNUM
MCS-TOUCH – CONNECTION
ETHERNET TO ONE MCS-MAGNUM
MCS-TOUCH – CONNECTION
ETHERNET TO MULTIPLE MCS-MAGNUMS
For additional information please visit our website
www.mcscontrols.com
Or call MCS at 239-694-0089