* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download simocode-dp
Power engineering wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Earthing system wikipedia , lookup
Automation bias wikipedia , lookup
Surface-mount technology wikipedia , lookup
Alternating current wikipedia , lookup
Induction motor wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Fault tolerance wikipedia , lookup
Rectiverter wikipedia , lookup
SIMOCODE pro System Automation and Drives The System Low-Voltage Controls & Distribution Starting Situation System System SIMOCODE pro C – Compact The compact system for: Direct starters and Reversing starters Components Functions Integration Practice Information Up to 80 % of all present SIMOCODE-DP applications at a price reduction of 20 %. SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Design of SIMOCODE pro Motor Feeders Low-Voltage Controls & Distribution Starting Situation SIMOCODE pro C – Compact Control circuit Main circuit Automation system System System Components Functions Connection Integration Cable Practice Information Current Measuring Module SIMOCODE pro Basic Unit 1 Operator Panel* (This document is subject to changes) *) Optional As of 09/04 Automation and Drives The System Low-Voltage Controls & Distribution Starting Situation System System SIMOCODE pro V – Variable The variable system with: All control functions and Variably expandable additional functions Components Functions Integration Practice Information SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Design of SIMOCODE pro Motor Feeders Low-Voltage Controls & Distribution Starting Situation SIMOCODE pro V – Variable Control circuit Main circuit Automation system System System Components Functions Connection Integration Cable Practice Information Current/Voltage Measuring Module* SIMOCODE pro Basic Unit 2 + Expansion modules* Operator Panel* (This document is subject to changes) *) Optional As of 09/04 Automation and Drives The System Low-Voltage Controls & Distribution Starting Situation System System Components has been designed for mixed operation. Targeted combination of SIMOCODE pro C and SIMOCODE pro V in the same switchgear, depending on the individual functional requirements SIMOCODE pro C is fully upward-compatible with SIMOCODE pro V Functions I.e. with a conversion to SIMOCODE pro V: Integration No re-wiring is required (removable terminals) Practice The current measuring module can remain in the main circuit Information No additional engineering is required (identical terminals) The pro C parameterization can be adopted unchanged pro V utilizes the same components as pro C (stock-keeping) A mixed application in the same switchgear does not produce extra costs – it saves costs! SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The System Low-Voltage Controls & Distribution Current Measuring Module Basic Unit Operator Panel Expansion modules Digital Modules + Voltage detection Earth Fault Module Temperature Module Analog Module Starting Situation System System Components Functions Integration Practice Information SIMOCODE pro C SIMOCODE-DP SIMOCODE pro V SIMOCODE pro (This document is subject to changes) As of 09/04 SIMOCODE pro The Components Automation and Drives The Components Low-Voltage Controls & Distribution SIMOCODE pro C – Compact Starting Situation Current Measuring Module System Basic Unit 1 4 I / 3 O binary Thermistor PROFIBUS-DP 24 V DC / 110 – 240 V UC 0.3 A – 630 A Straight-through/ busbar connection technology Components Components Functions Integration Practice Information Operator Panel Connection Cable 5 buttons / 10 LEDs In various lengths (up to 2 m) SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Components Low-Voltage Controls & Distribution Starting Situation SIMOCODE pro V – Variable Basic Unit 2 Current Measuring Module 4 I / 3 O binary Thermistor PROFIBUS-DP 24 V DC / 110 – 240 V UC 0.3 A – 630 A Straight-through/ busbar connection technology System Components Components Functions Connection Cable Integration In various lengths (up to 2 m) Practice Information Operator Panel Current/Voltage Measuring Module 5 buttons / 10 LEDs Expansion modules Additional binary I/Os 1 x 0/4 – 20 mA I/O 3 x sensors Pt100/ Pt1000 External earth fault via summation current transformer 0.3 A – 630 A / 690 V Straight-through/ busbar connection technology SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Current Ranges Low-Voltage Controls & Distribution Starting Situation Current Measuring Modules for all motor currents Widths: 45 mm 55 mm 120 mm 145 mm System Components Components Functions Integration Practice Information 0.3 – 3 A 2.4 – 25 A 10 – 100 A 20 – 200 A 63 – 630 A *) Straight-through transformer Busbar connection *) With 3UF18 intermediate transformers up to 820 A SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Voltage Range Low-Voltage Controls & Distribution Starting Situation Current/Voltage Measuring Modules Widths: 45 mm 55 mm 120 mm 145 mm System Components Components Functions Integration Practice Information 0.3 – 3 A 2.4 – 25 A / 690 V 10 – 100 A / 690 V 20 – 200 A / 690 V 63 – 630 A*) / 690 V Straight-through transformer Busbar connection SIMOCODE pro *) With 3UF18 intermediate transformers up to 820 A (This document is subject to changes) As of 09/04 Automation and Drives Variably Expandable Additional Functions Low-Voltage Controls & Distribution Starting Situation System Expansion modules for SIMOCODE pro V Up to 5 expansion modules can be connected to the Basic Unit 2: Digital Modules for: Max.2 Components Components Functions Integration Practice Information Additional binary I/Os Bistable relay outputs Externally supplied inputs (24 V DC or 110 – 240 V AC/DC) Earth Fault Module for: Max.1 Expansion of the internal earth fault monitoring by a sophisticated external monitoring with summation current transformer SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives Variably Expandable Additional Functions Low-Voltage Controls & Distribution Starting Situation System Expansion modules for SIMOCODE pro V Up to 5 expansion modules can be connected to the Basic Unit 2: Temperature Module for: Max.1 Components Components Functions Temperature monitoring of up to 3 analog temperature sensors (e.g.: Pt100/ Pt1000) Integration Practice Information Analog Module for: Max.1 Input/output and monitoring of analog signals (0/4 – 20 mA) for, e.g., filling level/flowrate monitoring or the actuation of a display unit SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives Smaller Dimensions SIMOCODE pro Improved scaling accuracy System Components Components Functions Integration Practice Information 45 mm 67.5 mm 90 mm 4 binary inputs 3 relay outputs Thermistor PROFIBUS DP 12 binary inputs 7 relay outputs Thermistor PROFIBUS DP All digital modules are combinable Additional functions 36 mm Starting Situation Including expanded functionality 96 mm SIMOCODE-DP 70 mm SIMOCODE pro 140 mm 4 binary inputs 4 relay outputs Thermistor PROFIBUS DP 12 binary inputs 8 relay outputs Thermistor PROFIBUS DP (This document is subject to changes) 60 mm Low-Voltage Controls & Distribution 96 mm As of 09/04 SIMOCODE pro The Functions Automation and Drives The Functions Low-Voltage Controls & Distribution Starting Situation System Components Based on SIMOCODE-DP. SIMOCODE pro is a flexible and modular motor management system for motors used in low-voltage applications. Functions Functions SIMOCODE pro integrates the following features in only one system: Integration Multifunctional Practice Information electronic motor protection Flexible software for motor control Detailed operating, service and diagnostics data Communication via PROFIBUS-DP Comprehensive motor feeder protection + flexible control! SIMOCODE pro (This document is subject to changes) As of 09/04 Automation and Drives The Functions Low-Voltage Controls & Distribution Starting Situation System Components Functions Functions Integration Practice Information More functions than ever before. Protective functions Control functions Overload protection (Class 5 - 40) Thermistor motor protection Phase failure monitoring Unbalance protection Stall protection Earth-fault monitoring Monitoring of current limit values Monitoring of operating hours Monitoring of motor stop times Number-of-starts monitoring Etc. Expanded monitoring functions: Temperature monitoring Pt100/ Pt1000 Voltage monitoring Power monitoring Cos-phi monitoring Phase sequence detection Input, output and monitoring 0/4-20 mA signal Measuring curves recording SIMOCODE pro Direct online starter Reversing starter Star-delta starter Star-delta starter with reversal of rotational direction Two speeds, motors with separate windings (pole changeover switch), also with reversal of rotational direction Two speeds, motors with separate Dahlander windings, also with reversal of rotational direction Solenoid valve actuation Positioner actuation Soft starter actuation Soft starter actuation with reversal of rotational direction Logic modules (truth tables, counters, timers, edge evaluation, limit monitoring...) and Standard functions (power failure monitoring, emergency start, external faults ...) (This document is subject to changes) As of 09/04 Automation and Drives The Functions Low-Voltage Controls & Distribution Starting Situation System Components Functions Functions Integration Practice Information What‘s New. Protective functions Control functions Overload protection (Class 5 - 40) Thermistor motor protection Phase failure monitoring Unbalance protection Stall protection Earth-fault monitoring Monitoring of current limit values Monitoring of operating hours Monitoring of motor stop times Numbers-of-starts monitoring Etc. Expanded monitoring functions: Temperature monitoring Pt100/ Pt1000 Voltage monitoring Power monitoring Cos-phi monitoring Phase sequence detection Input, output and monitoring 0/4-20 mA signal Measuring curves recording SIMOCODE pro Direct online starter Reversing starter Star-delta starter Star-delta starter with reversal of rotational direction Two speeds, motors with separate windings (pole changeover switch), also with reversal of rotational direction Two speeds, motors with separate Dahlander windings, also with reversal of rotational direction Solenoid valve actuation Positioner actuation Soft starter actuation Soft starter actuation with reversal of rotational direction Logic modules (truth tables, counters, timers, edge evaluation, limit monitoring...) and Standard functions (power failure monitoring, emergency start, external faults ...) (This document is subject to changes) As of 09/04 Automation and Drives The Data Low-Voltage Controls & Distribution Starting Situation System Components Functions Functions Integration Practice Information Even more detailed information on the motor feeder. Operating data Service data Motor switching state (on, off, left, right, slow, fast) Current in phase 1, 2, 3 and max. current Voltage in phase 1, 2, 3 Effective power Apparent power Power factor Phase unbalance Phase sequence Time to trip Motor model heating Remaining motor cooling time Temperature (e.g. motor temperature) Current analog signal value Etc. Communication 12 Mbps , automatic baud rate detection Time synchronization Cyclic and acyclic services SIMOCODE pro Motor operating hours Motor stop times Number of motor starts Number of overload trips Unit-internal storage of comments Unit operating hours Etc. Diagnostics data Numerous detailed early warning and fault messages, also for further processing within the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the main current circuit after ON control command) Etc. (This document is subject to changes) As of 09/04 Automation and Drives The Data Low-Voltage Controls & Distribution Starting Situation System Components Functions Functions Integration Practice Information What‘s New. Operating data Service data Motor switching state (on, off, left, right, slow, fast) Current in phase 1, 2, 3 and max. current Voltage in phase 1, 2, 3 Effective power Apparent power Power factor Phase unbalance Phase sequence Time to trip Motor model heating Remaining motor cooling time Temperature (e.g. motor temperature) Current analog signal value Etc. Communication 12 Mbps , automatic baud rate detection Time synchronization Cyclic and acyclic services SIMOCODE pro Motor operating hours Motor stop times Number of motor starts Number of overload trips Unit-internal storage of comments Unit operating hours Etc. Diagnostics data Numerous detailed early warning and fault messages, also for further processing within the device or the control system Device-internal fault logging with time stamp Time stamp marking of individually selectable status, warning and fault messages Value of the last tripping current Checkback faults (e.g. no current flow in the main current circuit after ON control command) Etc. (This document is subject to changes) As of 09/04 Automation and Drives Integration & Configuration Low-Voltage Controls & Distribution Starting Situation System Small auxiliary equipment with large time-saving potentials. Addressing Plug for assignment of PROFIBUS address without PC/ PG Assignment of a PROFIBUS address to one or several basic units within seconds. Components Functions Integration Integration Practice Memory Module for parameterization without PC/ PG Information Commissioning of a motor feeder within seconds. SIMOCODE pro (This document is subject to changes) As of 09/04 SIMOCODE pro Information Automation and Drives Information Low-Voltage Controls & Distribution www.siemens.com/simocode Starting Situation System Components Functions Integration “Conversion flyer” Practice Product brochure Information Information System manual SIMOCODE pro Selection and ordering data (This document is subject to changes) As of 09/04