Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Installation Instructions MicroSet Infrared Ceiling Sensor Model # OMR-P-0450-R Model # OMR-P-1200-R 10-30 VDC P/N 9850-000399-00 General Information • Readallinstructionsonbothsidesofthissheet first • Planallcomponentlocationscarefully • InstallinaccordancewithALLlocalcodes • ForusewithGreengateSwitchpacks&Greengate Systems.Forusewithothersystems,contact TechnicalSupport Coverage • Notforusewheretemperaturesfallbelow60°F orabove90°F • Forindooruseonly • DONOTrunanyGreengatelowvoltagewiringin thesameconduitaspowerconductors 15 ft (4.6m) Installation 30ft (9.1m) Top View 10ft (3m) 20ft (6.1m) 5ft (1.5m) 10ft (3.0m) 0’ Specifications Technology:PassiveInfrared(PIR) Power Requirements: Input: • 10-30VDCfromGreengateSwitchpackorGreengate system.Maximumcurrentneededis25mApersensor Output • Opencollectoroutputtoswitchuptoten GreengateSwitchpacks • IsolatedFormCRelay(-Rmodel) • IsolatedFormCRelayRatings:1A,30VDC/VAC Time Delays: • Self-Adjustingfrom10min.to30min. Ambient Light Features: • Adjustablefrom10to300foot-candles Operating Environment: • Temperature:60°F–80°F(15°C–26°C) • RelativeHumidity:Lessthan95%non-condensing • Forindooruseonly Housing: • Mediumimpactinjectionmoldedhousing.ABS resincomplieswithUL94V0 Size:3”diameterx1.43”deep (76.2mmdiameterx36.32mmdeep) LED Indicators:RedLED TheMicroSetTechnologycontainedwithinsensorcontinuouslyself-adjustssensitivityandtimedelayautomatically andimmediatelyinresponsetooccupantbehavior.Thereisnoneedfortimeconsumingmanualadjustmentsorto “learn”behaviorpatternsoverextensiveperiodsoftime. MicroSet™ Recessedt 10ft (3.0m) 10ft (3m) 20ft (6.1m) 15 ft (4.6m) Side View 30ft (9.1m) 0’ 0’ 12ft 9ft 7ft 5ft 3ft (3.7m) (2.7m) (2.1m)(1.5m)(0.9m) 0’ 12ft 7ft 9ft 3ft 5ft (0.9m) (1.5m) (2.1m) (2.7m) (3.7m) 8ft (2.4m) Side View Sensor Unit 24ft (7.3m) OMR-P-0450-R Coverage Diagram Up to 450 sq. ft. Description TheMicroSetPassiveInfraredceilingsensorscanbeusedindividuallyorincombinationtoprovidelightingcontrol andintegrationwithHVACcontrolthroughoutabuilding.Availableinrecessed,flushmountlowvoltagemodels. CAUTION: Finger-tighten the nut to avoid stripping the mounting post. 0’ 5ft (1.5m) 8ft (2.4m) Sensor: 1.Passwiresthroughthethreadedmountingpostandinterlocktothebackplate. 2.Sensormountstonormalceilingtilethroughasingle3/4”hole. 3.Whenmounted,thesensor’sslottedgrillsmustpointalongthepathwheremotionistobedetected. 4.Anadapterplate(ACMP)isavailabletoallowmountingtoastandardfixtureringandjunctionbox. 5.Thethreadedmountingpostmaybecutdownifitistoolongtofitintothejunctionbox. Top View 14ft (4.3) 8ft 8ft 14ft 3ft 0’ 3ft (2.4m) (0.9m) (0.9m) (2.4m) (4.3) 24ft (7.3m) OMR-P-1200-R Coverage Diagram Up to 1200 sq. ft. Switchpack: Designedtobemountedexternallytoanyjunctionbox.Whenmounted,lineconnectionsareinsidetheboxand theClass2wiringexitsthroughtherearoftheswitchpackhousing.InareaswhereClass2wiringisnotpermitted, theswitchpackcanbemountedinternallytoanystandardelectricalbox. Switchpack Location J Box Sensor: Followthediagramsshownconcerningmajorandminormotioncoverage. 1.Choosesensorlocationcarefully. Note:Thesensormusthaveaclear viewoftheareatobecontrolled.Itshouldnotbeblockedfrom“seeing”peoplebyhighpartitions.Thesensorwillnot“see” throughglass. 2.Mountingheightshouldnotexceed12ft.Topreventfalseactivation,thesensorshouldbemountedawayfromthe pathofstrongairturbulenceaminimumof4to6ft.Fortypicalplacementrefertolocationdiagramsbelow. Switchpack: Theswitchpackisgenerallymountedabovetheceilingontheoutsideofthejunctionboxthatcontainsahotline, neutralandtheexistingswitchlegfromwhichthelightingiscontrolled.Ifadditionalswitchpacksarerequired,theyare mountedontheoutsideoftheboxescontainingtheappropriateswitchlegs.Ininstallationswheretherearenoexisting switchlegs,theswitchpackmaybemountedontheoutsideofanyconventionalstandardjunctionbox,withorwithoutan extensionring. Locknut Coverplate 20’ 18’ 10’ S L - Shaped Office S 10’×12’ Office S Sensor S 15’× 20’ Conference Room Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com Wiring Checkout and Adjustment MANUAL MODE OPERATION: Nomanualadjustmentsnecessaryatinstallation.Thesensorwillautomaticallysetthetimedelaytothe recommendedsettingof10minuteswhenleftattheinstallertestsettingafterlightsareOFFforaminimumperiodof5 minutes.Atinstallation,thesensorwillscanthecoverageareatodeterminetheoptimumsensitivitysetting.MicroSet™ PIRCeilingSensorscontinuallyself-adjustsensitivityandtimedelayautomaticallyandimmediatelyinresponseto occupantbehavior,eliminatingtheneedto“learn”behaviorpatternsovertime.Thisreducestheneedforfollow-up adjustments.DIPswitchoverrideallowstimedelaytobelockedat30minutes. 1. SWITCH IS REQUIRED TO TURN LOAD ON. 2. LOAD TURNS OFF WHEN SENSOR TIMES OUT OR WITH SWITCH. HOT AUTOMATIC MODE OPERATION: LINE RED (15VDC) SWITCHPACK BLUE (CONTROL) RECOMMENDED WIRE: 18-3 AWG STRANDED WIRE SHIELDED OR NON/SHIELDED BLUE 3. IF DAYLIGHT SENSOR IS ENABLED AND LIGHT LEVEL IS ABOVE SETPOINT, SWITCHPACK CONNECTED TO YELLOW LEAD WILL NOT TURN LOAD ON. **HOT **USE BLACK LEAD FOR 120VAC. USE ORANGE LEAD FOR 277VAC. CAP UNUSED LEAD. 2. SWITCH CAN BE USED TO TURN LOAD ON OR OFF. WHITE NEUTRAL 1. WHEN SENSOR ACTIVATES, LOAD TURNS ON. LOAD "A" BLUE BLACK (COMMON) RED (10-30VDC) Note:NOTES BLUE (CONTROL-OCC) 1. LOADS MAY BE ON SAME 1.LOADSMAYBEONSAME CIRCUIT OR DIFFERENT CIRCUITS OR VOLTAGES. CIRCUITORDIFFERENTCIRCUITSOR VOLTAGES. 2. SP20-MV SWITCHPACK SHOWN. 120/277VAC 20AMP RATING. 2.SP20-MVSWITCHPACKSHOWN. 20/277VAC20AMPRATING. BLACK (COMMON) PURPLE (NORMALLY CLOSED) YELLOW (CONTROL-OCC/DAY) GRAY (COMMON) MODEL GMDS - LOAD "A" (NORMALLY OPEN MOMENTARY SWITCH) BROWN (BLUE CONTROL) ORANGE (NORMALLY OPEN) DIP Switches 1-8 DIP Switch Settings 1 DIP Switches 1-8 2 3 4 Note:Thepreferredmodeistoleave 1 - Auto/Manual Mode - 5 6 7 8 2 - Enable Lighting Sweep allDIPswitchesinthedefaultposition. A ON 3 4 5 6 7 6 - Light Level A 50 FC 8 - Light Level C 1 2 Lighting Sweep On Mode Position2 ManualON Enabled Position1 (Default) AutoON NotEnabled 3 Time Delay 5 4 Override Lockedat 30minutes SelfAdjusting Daylight Logic 20 FC 7 LightLevel B 1.FlipDIPswitch2toposition2. 2.LeaveDIPswitchatposition2for1second. 3.FlipDIPswitchbacktoposition1. 4.Remainstill.TheLEDwillnotflash.ThelightsshouldturnOFFafter15seconds.(Ifnot,see“Troubleshooting.”) 5.Moveaboutthecoveragearea.ThelightsshouldcomeON. 10 FC Not Enabled 6 LightLevel A Daylight Adjustments Full and Half Logic Modes (See DIP Switch legend): InbothFullandHalfLogicmodes,lightsconnectedtotheyellowcontrolleadwillnotturnONuponoccupancy activation,shouldtheambientlightlevelexceedthepresetfoot-candlelevel. After activation: FullLogicMode-shouldtheambientlightlevelexceedthepresetfoot-candlelevel,thelightsconnectedtothe yellowcontrolleadwillturnOFF.ThelightswillremainOFF,untiltheambientlightlevelfallsbelowthesetpoint. HalfLogicMode–theoutputstateoftheyellowcontrolleadwillnotchangewithambientlightchanges,after occupancyactivation. delayis15seconds.However,sensorautomaticallyadjuststothesurroundingenvironment;thustestingthesensorisnotrequired. 30 FC See “Light Level Settings” chart 7 - Light Level B See Chart Lighting Sweep Whensensorsareusedinconjunctionwithcomputerlightingsweepsystems,youMUSTenabletheLightingSweep featurebyturningDIPswitch2toposition2.Enablingthisfeaturepreventsanunneccecessary“lightsON”followingthe computerpower-onsweep. Note:SensorisnowinTestmode.SensorwillremaininTestmodeaslongaslightsarenotcontinuouslyOFFfor5minutes.DuringtheTestmode,thetime 70 FC 5 - Half/Full Daylight Logic - Full Logic 8 C 100 FC 4 - Enable Default to ON - ON (Override) 2 B 150 FC 3 - Locked 30 Minute Delay - ON (Self Adjust ) 1 LIGHT LEVEL SETTINGS ON Troubleshooting 8 LightLevel C Override FullLogic Enabled Enabled Enabled Normal HalfLogic NotEnabled NotEnabled NotEnabled Issue Possible Causes Suggestions WallSwitchOFF TurnWallSwitchON. Lights Will Not Turn ON automatically Iflowvoltageswitchoptionisused,lightsmay havebeenturned-offmanually. Presslow-voltageswitch. DaylightFeatureEnabled IfalllightsarerequiredtoturnONadjustDIPSwitch10and/ ordaylightpotentiometer Powerinterruption Checkincomingvoltageand/orwiring DaylightFeatureEnabled IfalllightsarerequiredadjustDIPswitch10and/ordaylight potentiometer. Powerinterruption Checkincomingvoltageand/orwiring Lights Will Not Turn ON manually If lights will still not turn ON, set sensor to override mode and call Technical Services at 1-800-553-3879 Lights Will Not Turn OFF automatically Testingisnowcomplete.Simplyleavethearea.LightsshouldturnOFFafter15seconds.After5minutesofthelights beingOFF,sensorwillautomaticallygointousermode. Lights Will Not Turn OFF manually Override MakesuresensorisnotinOverrideMode(DIPSwitch8up). UltrasonicSensitivitysetHigh LowersensitivitybyturninggreenpotentiometerCCWin smalldecrements. Sensorinstalledclosetoanairvent Sensorsshouldbeinstalledminimum4-6feetawayfrom anyairventandoutofpathofheavyairflow. Sensorinstalledclosetoindirectlighting. Sensorsshouldbemountedawayfromindirectlighting. Self-adjust Itmaybepossiblefortheunittohaveself-adjustedthetime delaytoa30minutedelay.IfthelightsdonotturnOFFafter 30minutesfollownextstep. 30MinuteDelay Maximumtimedelayis30Minutes.CheckDIPSwitchesto verifyDIPSwitchsettings.IflightsdonotturnOFFattheset timedelay,checknextstep. PIRactivatedbyheatsourceotherthanoccupant MoveDIPSwitch5up. Bypass Checkwiringtomakesuresensororswitchpackarenot bypassed. Override MakesuresensorisnotinOverrideMode(DIPSwitch8up). If lights will still not turn OFF, call Technical Services at 1-800-553-3879 Warranties and Limitation of Liability Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions. Printed in Malaysia Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com