* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download RJ45 Modular Jack Connectors with Pulse Transformers
Survey
Document related concepts
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Earthing system wikipedia , lookup
Optical rectenna wikipedia , lookup
Printed circuit board wikipedia , lookup
Gender of connectors and fasteners wikipedia , lookup
Surface-mount technology wikipedia , lookup
Electrical connector wikipedia , lookup
Transformer wikipedia , lookup
Transcript
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. RJ45 Modular Jack Connectors with Pulse Transformers TM11RD - 5TANA Series Pulse Transformer Circuit Diagram Insulated transformer Choke coil TD+ 1 CT 3 TX- 2 RD+ 7 CT 6 RD- 8 1 TX+ 2 TX3 RX+ 4 5 6 RX7 8 4 GRAND 5 Circuit PCB ■Features RJ45 RJ11 (6 position) plug insertion prevention 1. Pulse Transformers Support FastEthernet Equipped with built-in insulation transformers and common mode choke coils, withstanding voltage of 1.5 kV and supporting 100Base-Tx and 10Base-T. Outline of mating plug 2. Incorrect Plug Insertion Prevention Key A built-in key offers protection against insertion of 6conductor type modular plug. 3. Built-in optical indicators Optical indicators are integral part of the connectors, saving space on the board. There is no emission of any electrical noise. Incorrect Plug Insertion Prevention Key 4. EMI protection Metal shield covers the outer surfaces of the connectors assuring complete protection against electromagnetic interference. 5. FCC standards Meets requirements of FCC Title 47, Part 68, Subpart F. Built-in optical indicators 6. Environmental considerations Plating compounds are lead-free. ■Applications Light pipe Notebook PC's, telecommunication hubs, routers, bridges and ATM transmission equipment, Ethernet switches and networking equipment, office equipment, test and measurement equipment. * Light colors are determined by the color of LED's used. 2006.8 1 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. ■Product Specifications Voltage rating 125V AC Ratings Connector Pulse transformer Operating temperature range: -25ç to +80ç (Note) Item 1.Insertion resistance 2.Insulation resistance Specification -2dB min. 100M ohms min. 3.Withstanding voltage No flashover or insulation breakdown. 4.Insertion resistance -1dB min. -20 dB max. -16 dB max. -12 dB max. -10 dB max. 350µH min. -40 dB max. -35 dB max. -30 dB max. -30 dB max. -20 dB max. 5.Return loss 6.Inductance 7.Cross talk (Reference) 8.Common mode rejection ratio (Reference) Conditions 1 to 65MHz 100V DC Basic terminal between 123-45-768 500V AC / one minute Primary (RJ45 side) to secondary (PCB side) 1500V AC / one minute Terminal to shield 1500V AC / one minute 1 to 65MHz 1 to 10 MHz 10 to 30 MHz 30 to 60 MHz 60 to 80 MHz 0.1V, 100KHz, 8mADC 1 to 30 MHz 30 to 60 MHz 60 to 100 MHz 1 to 50 MHz 50 to 150 MHz Note: Includes temperature rise caused by current flow. ■Materials Material Finish/Color Remarks Insulator Component PBT Black UL94V-0 Contacts Copper alloy Shield Copper alloy Contact area : Gold plated Termination area: Tin plated Tin plated Stainless Incorrect insertion prevention key Pulse transformer Optical pipe ---------- ---------- Polycarbonate Clear ■Ordering information 1 Series name 2 Connector type 3 Direction of locking lever TM11 R D - 5 T A NA - A - 8 8 - LP 1 2 2 3 4 5 6 7 8 9 10 4 5 6 7 8 9 10 (mating plug) Jack suffix number Transformer Transformer type Incorrect insertion prevention key Jack opening code Number of inserted contacts Optical pipe UL94V--0 : TM11 R: Jack D: Down :5 T: With transformer A: Transformer circuit type NA-A: With built-in key 8: 8 contacts 8: 8 contacts LP: With optical pipe inserted Blank: Without optical pipe The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative. ■Modular Jack Connectors (With built-in optical pipe) Contact No.1 21.3 3.18 3.56 Contact No.8 1.6 16 13.6 Contact No.1 Contact No.8 10.8 0.48 15.75 17.5 Part Number CL No. RoHS TM11RD-5TANA-A-88-LP CL222-2936-3 YES BRecommended PCB mounting pattern 0.3 24.2 4 Suggested dimensions of LEDs 20.75MIN 11.43 10.75MAX LED light emitting center Printed board edge 7.4 Ø3.25 12.7 6.2 2.7MAX 7 5 3 1 8 6 4 2 3.2MAX No conductive traces 1.5MAX Ø1.63 5.55MIN 3.05 2.54 8-Ø0.9 1.27 LED center position 8.89 5 11.6 15.75 BPulse Transformer Circuit Diagram CT 3 TD- 2 1 TX+ 2 TX- 1CT:1CT RD+ 7 CT 3 RX+ 6 RD- 8 4 CHS GROUND 5 1CT:1CT 75ø 75ø 75ø 0.001µF 75ø Cable side Board side TD+ 1 6 RX4 5 7 8 ●Precautions 1 2 3 4 5 6 7 Hirose Electric did not check the compatibility with the PHY chip. When replacing other manufacturers jack it is recommended to verify the compatibility with the actual equipment. This connector is mounted on the board using wave or manual soldering. Do not use reflow soldering. Recommended board thickness: 1.6mm To assure correct operation of the indicator light pipes LED's must be installed directly on the PCB, within recommended dimensions and with light emitting center in upward direction. Mount the LED so that the center of the light emitting center aligns with the center point as dimensioned on the Recommended PCB mounting pattern above. Verify the actual LED's mounting pattern with it's manufacturer, then add it to the PCB mounting pattern, assuring the correct placement of the center point. IPA cleaning at room temperature is recommended for the cleaning of this product. When an aqueous cleaning agent is to be used, there is a concern that the light pipe (made of polycarbonate resin) may change color; therefore, please make a selection based on a table showing the effects on the resin.These tables are issued by the various manufacturers of cleaning agents. 3 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales represent ■Modular Jack Connectors (Without built-in optical pipe) Contact No.1 21.3 3.18 3.56 Contact No.8 1.6 16 13.6 Contact No.1 Contact No.8 0.48 10.8 0.3 15.75 17.5 Part Number CL No. RoHS TM11RD-5TANA-A-88 CL222-2932-2 YES BRecommended PCB mounting pattern No conductive traces 20.75MIN 11.43 10.75MAX Printed board edge 6.2 7.4 Ø3.25 2.54 5.55MIN 3.05 7 5 3 1 8 6 4 2 Ø1.63 8-Ø0.9 1.27 8.89 15.75 BPulse Transformer Circuit Diagram CT 3 TD- 2 1 TX+ 2 TX- 1CT:1CT RD+ 7 CT 3 RX+ 6 RD- 8 4 1CT:1CT 75ø 75ø 75ø 0.001µF 75ø CHS GROUND 5 Cable side Board side TD+ 1 6 RX4 5 7 8 ●Precautions 1 Hirose Electric did not check the compatibility with the PHY chip. When replacing other manufacturers jacks it is recommended to verify the compatibility with the actual equipment. 2 This connector is mounted on the board using wave or manual soldering.Do not use reflow soldering. 3 Recommended board thickness: 1.6mm 4 IPA cleaning at room temperature is recommended for the cleaning of this product. When an aqueous cleaning agent is to be used, there is a concern that the light pipe (made of polycarbonate resin) may change color; therefore, please make a selection based on a table showing the effects on the resin.These tables are issued by the various manufacturers of cleaning agents. 4 The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information. All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales represent ■Technical Data Measurement results of electrical characteristics ●Insertion Loss Insertion Loss Network analyzer 0 dB 0 -0.2 -0.4 -0.6 10 20 30 MHz 40 50 60 70 80 50 60 70 80 -0.8 -1 -1.2 -1.4 -1.6 -1.8 -2 Pulse transformer section ●Reflection Loss Reflection Network analyzer 0 0 10 20 30 MHz 40 -10 dB -20 -30 -40 -50 -60 -70 Pulse transformer section -80 ●Crosstalk (Reference) Cross Talk Network analyzer 0 0 10 20 30 40 MHz 50 60 70 80 90 100 -10 -20 dB -30 -40 -50 -60 -70 Pulse transformer section -80 -90 -100 ●Common Mode Rejection Ratio (Reference Value) CMRR Network analyzer 0 0 10 MHz 20 30 40 50 60 70 80 90 100 110 120 130 140 150 -10 dB -20 -30 -40 -50 -60 Pulse transformer section -70 -80 5