* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Transformer Specification Sheet
Power inverter wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Ground (electricity) wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Stepper motor wikipedia , lookup
Transformer wikipedia , lookup
Schmitt trigger wikipedia , lookup
Electrical substation wikipedia , lookup
Nominal impedance wikipedia , lookup
Electrical ballast wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Current source wikipedia , lookup
Resonant inductive coupling wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Buck converter wikipedia , lookup
Power MOSFET wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Transformer Specification Sheet Customer Name: Contact Name: Address: City: State: Zip: Phone: Email: Existing Acutran Design Number if Known: Select... Quote Number: Power Rating: Type: KVA Select... Phase Three Phase or Single Phase D/D, D/Y, Y/Y, Y/D. Include all relevant "type" information in this box that is not shown elsewhere. Configuration: Nominal Primary Line to Line Voltage (H): Vrms Line to Line volts Nominal Primary Phase Voltage: Vrms For wye connection divide H by sqrt3 Enter either +/- voltage or +/- percent from Nominal Primary Tap Voltages or %: Nominal Secondary Line to Line Voltage (X): Vrms Line to Line Nominal Secondary Phase Voltage: Vrms For wye connection divide X by sqrt3 Enter either +/- voltage or +/- percent from Nominal Secondary Tap Voltages or %: For single frequency operation complete Maximum value Operating Frequency: Hz Required Efficiency: % Maximum Ambient Temperature: °C Default 30°C Maximum Temperature Rise: °C Standard range 150 - 180°C if accessible must limit external temperature rise to 65°C. kV Rating Class as detailed in IEEE C57-12-01 2007. Lowest BIL is 10kV for class 1.2kV higher levels apply for classes above this. Primary BIL/Secondary BIL: Max Width: inches Max Depth: inches Front to Back Max Height: inches Max Elevation: Enclosure required? If yes specify type: Ventilation Class: ft Standard design up to 1000m(3300') above sea level. Yes & Type or No Nema 1, Nema 3 etc. AA, AFA, ETC AA = Ventilated Self-Cooled, AFA = Ventilated Forced Air Cooled. ZIG-ZAG ADDITIONAL SPECIFICATIONS Fault Current Amps Fault Current Carry Time Series Resistor Required Resistance value Target Impedance Seconds Select... Yes or No If yes resistor will be supplied with transformer Ohms % OTHER NON-STANDARD SPECIFICATIONS/INSTRUCTIONS Acutran • 1711 Route 588 • Fombell, PA 16123 Phone: 724.452.4130 • Fax: 724.452.4690 • Email: [email protected] © 2008 Acutran All Rights Reserved