Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
COLLIER COUNTY PUBLIC UTILITIES SOLID AND HAZARDOUS WASTE DIVISION COLLIER LANDFILL MOV INTEGRATION JUNE 2015 COLLIER COUNTY PUBLIC UTILITIES SOLID & HAZARDOUS WASTE MANAGEMENT DEPARTMENT DIRECTOR DAN RODRIGUEZ PROJECT MANAGER - DAYNE ATKINSON BROWN AND CALDWELL ENVIRONMENTAL - HALA SFIER P.E. PHD INSTRUMENTATION AND ELECTRICAL - DUSTIN SAYRE PROCESS AND MECHANICAL - ANAND MODY P.E. PROJECT SITE collier county logo_v002.tif County.PNG Vicinity.PNG DRAWING INDEX G-001 GENERAL SITE PLAN E-001 ELECTRICAL DETAILS 1 E-002 ELECTRICAL WIRING DIAGRAM Jun 02, 2015 - 3:33pm C:\Users\DSayre\Documents\Collier\_CAD\2-Sheets\G-000.dwg dsayre ATTACHMENT A - STANDARD VALVE WIRING DIAGRAM NAPLES LANDFILL 3730 WHITE LAKE BLVD. NAPLES, FL 34117 AUTHORIZATION # 0000 850 TRAFALGAR CT, STE 300 MAITLAND, FL 32751 1 3 2 5 4 6 GENERAL NOTES: 1. LOCATIONS OF BUTTERFLY VALVES AND ELECTRIC VALVE OPERATORS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY PIPES AND DECIDE WITH OWNER EXACT INSTALLATION LOCATIONS. AUTHORIZATION #0000 MAITLAND, FL 2. 8" GRAVITY PIPE FROM CELL 6 D 3. HAND DIG ALL CONDUIT TRENCHES AND HANDHOLES. REFER TO OWNER FOR EXACT LOCATION OF EXISTING FIBER OPTIC CABLE AND ELECTRICAL CONDUITS. D EXISTING PIPE LOCATIONS ARE APPROXIMATE. EXACT PIPE LOCATIONS ARE TO BE LOCATED BY CONTRACTOR WITH COORDINATION FROM THE OWNER. SHEET KEY NOTES: .NEW MOV LOCATIONS 6" PIPE FROM EAST CELLS 2 1 LOCATE EXISTING SPARE CONDUITS TO PP-1000 AND LCP-1000. ROUTE EXISTING SPARE CONDUITS INTO NEW HANDHOLE. 2 PROVIDE NEW CONDUIT TO MOVS. 3 PULL WIRING THROUGH EXISTING SPARE CONDUIT INTO LCP-1000 AND PP-1000 PANELS AND TERMINATE WIRING. COORDINATE WITH OWNER ON EXISTING SPARE BREAKER PANEL SLOTS AND PLC TERMINALS TO LAND NEW WIRING. C C LEGEND: 1 2 WETWELL 8" PIPE ELEVATION = 8.60' HAND HOLE, PULL BOX TOP OF WETWELL ELEVATION = 14.22' 6" PIPE ELEVATION = 11.49' PLOT DATE: 6/2/15 CAD USER: SAYRE, DUSTIN COLLIER LANDFILL MOV INTEGRATION REVISIONS REV B 3 DATE DESCRIPTION # # # # # # # # # # # # # # # # # # # # # B LINE IS 2 INCHES FILENAME: G-001.DWG Path: C:\USERS\DSAYRE\DOCUMENTS\COLLIER\_CAD\2-SHEETS collier county logo_v002.tif JDiedrich Sign Seal and Date.png GAS CONDENSATE UNIT AT FULL SIZE DESIGNED: D SAYRE ELECTRIC PANEL DRAWN: D SAYRE CHECKED: A MODY CHECKED: APPROVED: H SFEIR FILENAME G-001.DWG BC PROJECT NUMBER ###### CLIENT PROJECT NUMBER ###### 3 CONTROL PANEL GENERAL A A SITE PLAN STANDBY GENERATOR DRAWING NUMBER G-001 SHEET NUMBER 2 OF 1 2 3 4 5 6 1 3 2 5 4 6 PROTECTIVE CONCRETE BOOT GRADE FINISH SLAB SIGNAL LEADS OUTER JACKET LUG (TYPICAL) LIQUID-TIGHT FLEXIBLE (UV) RESISTANT STEEL CONDUIT TO EQUIPMENT 3" SHIELD GROUND LEAD PVC COATED RIGID CONDUIT TERMINATION OF SHIELDED CONTROL CABLE SHIELD GROUNDED AT TERMINATION IN PLC PANEL. PVC COATED HUB SIZE STAINLESS STEEL ANGLE L (2-1/2 x 2-1/2 MIN.) OR SIMILAR UNISTRUT SYSTEM WITH METAL END-CAPS REINFORCING STEEL CONDUIT RISERS FROM DUCT BANK #4 @ 36" MAX 5" #4 @ 24" MAX D VAR CONDUIT DUCT (TYPICAL) SCALE: NONE SHIELD 1/2" STAINLESS STEEL EXPANSION TYPE CONCRETE ANCHORS INTO CONCRETE BASE OR SLAB NOTES: 1. 2. 3. 4. NUMBER AND SIZE OF ELECTRICAL DUCTS AS INDICATED ON DRAWING E-002. OSHA APPROVED 6" WIDE RED WARNING TAPE (IDEAL DU-601 OR EQUAL). DIMENSIONS ARE MINIMUM AND TYPICAL FOR OUTSIDE SURFACES. BOND GROUNDING CONDUCTOR TO ALL GROUNDING ELECTRODES ALONG ITS PATH INCLUDING GROUNDING GRID ELECTRODE AT EACH END OF THE DUCTBANK. 5. SADDLE-TYPE CONDUIT SPACERS REQUIRED EVERY 8' (CARLON SNAP-LOC, SNAP-N-STAC, OR EQUAL). OUTER JACKET PVC COATED COUPLING 24" CONDUCTOR LUG (TYPICAL) COUPLING/ADAPTER SHRINK TUBING INSULATION CONCRETE PAD 3000 PSI (36"L X 36"W X 18"D) #5 @ 12"EW, T&B CHAMFER CORNERS FINISH GRADE 6. *PROVIDE 2" SEPARATION FOR CONDUITS LESS THAN 4". 7. *PROVIDE 3" SEPARATION FOR CONDUITS 4" AND LARGER. CONDUIT AS SPECIFIED C * DETAIL COVER THIS PORTION WITH SHRINK TUBING 3/16 NOTE: THE 24" DIMENSION DOES NOT APPLY WHERE CONDUITS ARE INSTALLED IN SLAB. DUCTBANK RISER LESS THAN 18" IN WIDTH OR DEPTH 6" FINISHED GRADE OR FINISHED FLOOR CONCRETE SLAB FEMALE ADAPTOR OR COUPLING C 8" TERMINATION OF SHIELDED CONTROL CABLE SHIELD NOT GROUNDED AT FIELD TERMINATION 12" PVC COATED CONDUIT SUPPORT WITH STAINLESS STEEL MOUNTING HARDWARE CLASS A1 FILL 5" CLASS E (2000 PSI MINIMUM) RED CONCRETE ENCASEMENT PER SPECIFICATION SECTION 03300 MAITLAND, FL CONDUIT AS SPECIFIED D 3" SHRINK TUBING SPACER 5" CONTINUOUS BARE COPPER #4/0 GROUNDING CONDUCTOR 12" MIN. 6"x6"x4" STAINLESS STEEL CONTINUOUS HINGE NEMA TYPE 4X JUNCTION BOX OR BOX SIZE AS REQUIRED WARNING TAPE 12" D SHRINK TUBING AUTHORIZATION #0000 COVER DEPTH 24" OR AS INDICATED ON DRAWINGS PVC COATED LIQUID-TIGHT CONNECTOR 12" COVER THIS PORTION WITH SHRINK TUBING 1 COUNDUIT STUB-UP AND TRANSITION J-BOX SUPPORT CONTROL CABLE GROUNDING METHODS CLASS A1 FILL REINFORCED CONCRETE ENCASED DUCT BANK 12" #4 8" DETAIL A VAR DETAIL PLOT DATE: 6/2/15 CAD USER: SAYRE, DUSTIN DETAIL SCALE: NONE C VAR HAND CRANK TO MANUALLY OPEN/CLOSE VALVE ON POWER LOSS 12" 3 #6 REINFORCED CONCRETE PAD SCALE: NONE DETAIL COLLIER LANDFILL MOV INTEGRATION E VAR SCALE: NONE LIQUID TIGHT FLEXIBLE METAL CONDUIT NAMEPLATE REVISIONS REV NEMA 4X, STAINLESS STEEL, DISCONNECT SWITCH B HEAVY DUTY ACCESS COVER PRECAST CONCRETE COVER JUNCTION BOX FOR SIGNAL WIRING AND SURGE SUPPRESSOR ELECTRIC MOTOR OPERATOR FOR MODULATING BUTTERFLY VALVE CONDUIT CLAMP (TYPICAL) SUPPORT BRACE PRECAST CONCRETE RISERS AS REQUIRED EQUIPMENT CONCRETE PAD ELECTRIC MOTOR OPERATOR PIPE STAND PEDESTAL PROVIDED BY MANUFACTURER 1" MINIMUM FINISHED GRADE OR PAVEMENT CONDUIT(S) MOUNTING STAND PER DETAIL FLANGE MOUNT SUPPORT SIZED FOR FULL WEIGHT SUPPORT OF ELECTRIC MOTOR OPERATOR AND GEARBOX ASSEMBLY FILENAME: E-001.DWG Path: C:\USERS\DSAYRE\DOCUMENTS\COLLIER\_CAD\2-SHEETS collier county logo_v002.tif JDiedrich Sign Seal and Date.png SCALE: NONE B VAR 8" 1 A MOTOR OPERATED VALVE AND DISCONNECT SWITCH DETAIL F VAR 6. MOUNTING PIPE STAND REQUIREMENTS VARY WITH EQUIPMENT SIZE. CONDUIT NUMBER, SIZE AND CONFIGURATION VARIES. REFER TO APPLICABLE ONE LINE DIAGRAMS. PROVIDE CONTROL STATION NAMEPLATE INDICATING EQUIPMENT TAG NUMBER AND DESCRIPTION. SEPARATE POWER AND SIGNAL WIRING IN DIFFERENT CONDUITS. CONTRACTOR SHALL COORDINATE WITH ELECTRIC MOTOR OPERATOR MANUFACTURER TO PROVIDE REQUIRED PIPE STAND SHAFT SUPPORTS. APPROXIMATE RADIAL LOAD OF 500 LBS SHALL BE CONFIRMED BY MANUFACTURER. CONCRETE SLAB SHALL BE DESIGNED TO ACCOMMODATE A MAXIMUM TORQUE LOAD OF 3000 FT-LBS APPLIED TO BASE OF THE ELECTRIC MOTOR OPERATOR PIPE STAND PEDESTAL. SCALE: NONE 1 # # # # # # # # # # # # # # # # # B DESIGNED: D SAYRE PULLING IRON (TYPICAL) DRAWN: D SAYRE CHECKED: A MODY APPROVED: H SFEIR FILENAME E-001.DWG BC PROJECT NUMBER ###### CLIENT PROJECT NUMBER ###### 9" PEA GRAVEL BASE SECTION ELECTRICAL 1. 2. 3. 4. HANDHOLE/PULLBOX DEPTH, SIZE AND LOCATION AS REQUIRED PER DRAWINGS. MINIMUM INTERIOR DIMENSIONS SHALL BE 3' x 3' x 3'D UON. BOND DUCTBANK GROUND CONDUCTORS TOGETHER. H-20 LOAD RATED COVER FOR TEST WELL IN TRAFFIC AREA. A DETAIL 1 RACEWAY BOXES HANDHOLE/ PULLBOX DETAIL DRAWING NUMBER G VAR E-001 SCALE: NONE 2 # AT FULL SIZE NOTES: NOTES: 4. 5. # CHECKED: UNDISTURBED OR COMPACTED EARTH 3. # LINE IS 2 INCHES MINIMUM 6" DIAMETER DRAIN HOLE WITH FIBERGLASS OR ALUMINUM FRAME AND GRATE COMPACTED SAND TO SUPPORT CONCRETE PAD 1. 2. DESCRIPTION # PRECAST CONCRETE HANDHOLE/PULLBOX KNOCKOUTS AS REQUIRED FOR DUCTBANKS STAND AND STUB-UP CONDUIT(S) AT REAR OR SIDE OF SLAB BELOW GRADE BUTTERFLY VALVE WITH VALVE STEM ASSEMBLY FOR ELECTRIC MOTOR OPERATOR MOUNTING DATE 3 4 SHEET NUMBER 3 OF 5 6 1 3 2 5 4 6 GENERAL NOTES: 1. WIRING DIAGRAMS ONLY REFLECT WIRING AND BREAKERS ASSOCIATED WITH THIS PROJECT. REFER TO OWNER FOR COMPLETE SET OF CURRENT DRAWINGS AND PLANS. 2. VERIFY WITH OWNER SPARE BREAKERS AND PLC SPARE IO AT TIME OF INSTALLATION. 3. LABEL BREAKERS AND WIRING USING SIMILAR LABELS AS ARE CURRENTLY BEING USED IN EXISTING PANEL. USE NEXT AVAILABLE NUMBER IN EXISTING NUMBERING SCHEME. 4. I/O WIRING DRAWING IS TYPICAL FOR NEW I/O. USE THIS DRAWING AS A TEMPLATE FOR AS-BUILT I/O WIRING DRAWINGS. FILL IN ALL TERMINAL NUMBERS, WIRE NUMBERS, PLC ADDRESSES AND MODULE CONFIGURATION INFORMATION. 5. REFERENCE APPENDIX A FOR ELECTRIC MOTOR OPERATOR MANUFACTURERS WIRING DIAGRAM. LCP 1000 RISER DIAGRAM D 1 20A AUTHORIZATION #0000 MAITLAND, FL D 20A 2 30A 2#16 STP, 1" C C 3-#12, #12G, 1"C 3-#12, #12G, 1"C SHEET KEY NOTES: 1 PROVIDE QTY 2 NEW BREAKERS 20A, 480V, 22KAIC, SERVICE FROM EXISTING BREAKER PANEL TO NEW ELECTRIC MOTOR OPERATORS. 2 PROVIDE QTY 2 NEW DISCONNECT SWITCHES. 3 2K RESISTOR IS REQUIRED TO ESTABLISH LOAD CURRENT FOR HART COMMUNICATIONS. 4 TO 20 mA IS NOT USED IN THIS CIRCUIT. C 30A Path: C:\USERS\DSAYRE\DOCUMENTS\COLLIER\_CAD\2-SHEETS collier county logo_v002.tif JDiedrich Sign Seal and Date.png CV-1001 CV-1002 CONTROL CONTROL VALVE VALVE CV-1011 CV-1012 CONTROL CONTROL VALVE VALVE COLLIER LANDFILL MOV INTEGRATION REVISIONS REV B HART PROTOCOL ANALOG INPUT DIAGRAM DATE DESCRIPTION # # # # # # # # # # # # # # # # # # # # B # LINE IS 2 INCHES FILENAME: E-002.DWG PLOT DATE: 6/2/15 CAD USER: SAYRE, DUSTIN J FIELD PLC - LCP 1000 AT FULL SIZE DESIGNED: D SAYRE DRAWN: D SAYRE CHECKED: A MODY CHECKED: ELECTRIC MOTOR OPERATOR ANALOG INPUT TERMINAL HART PROTOCOL # APPROVED: H SFEIR BLACK BLACK TB# CLEAR CLEAR 4 ## # EDCO DRS-036 FILENAME E-001.DWG BC PROJECT NUMBER ###### CLIENT PROJECT NUMBER ###### BLACK SURGE SUPPRESSOR CLEAR 1 IN+ 2K RESISTOR 3 ## 5 2 ## 6 3 RACK 0 SLOT 6 + 24 VDC - RTN ELECTRICAL INPUTS 1 AND 2 A A SINGLE LINE DIAGRAM AND RISER DIAGRAM DRAWING NUMBER E-002 SHEET NUMBER 4 OF 1 2 3 4 5 6