Download HAWKEYE 720 Installation Instructions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

Operational amplifier wikipedia , lookup

Nanogenerator wikipedia , lookup

CMOS wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Ohm's law wikipedia , lookup

Radio transmitter design wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Lego Mindstorms wikipedia , lookup

Power electronics wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Current mirror wikipedia , lookup

Rectiverter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
Installation Instructions
INSTALLATION
!CAUTION !
• This product is not intended for life or safety
applications
• Installing sensors in an energized motor control
center or on any energized conductor can be hazardous.
Severe injury or death can result from electrical shock during contact
with high voltage conductors or related equipment. Disconnect and
lock-out all power sources during installation. Applications shown are
suggested means of installing sensors, but it is the responsibility of the
installer to ensure that the installation is in compliance with all national
and local codes. Installation should be attempted only by individuals
familiar with codes, standards, and proper safety procedures for highvoltage installations. Do not rely on status indications of device exclusively to determine of power is present in conductor.
HAWKEYE 720
Industrial Accuracy
Analog Current Sensor
VERIS INDUSTRIES, INC.
10831 S.W. CASCADE BLVD.
PORTLAND, OREGON 97223
(503) 598-4564 FAX (503) 598-4664
1-800-354-8556
http://www.veris.com email:[email protected]
CALIBRATION
20 TO 200A (#720)*
SENSOR
OUTPUT
1. Ensure power conductor to be monitored is disconnected and
locked out from the power source!
3.5 to 4.5 mA
(Zero Adj.)
SENSED AMPS
2. Install the adjustable mounting bracket to the back or floor of the
motor control center. The sensor may be located at any point on the
conductor between the motor and the motor starter.
3. Position the sensor body such that the hole is aligned to permit
the conductor to fit through the hole. Slide the conductor through
the center hole in the sensor and connect the conductor to the lugs
on the motor starter.
4. Wire the sensor as shown below. NOTE: if you desire a 1-5VDC
output signal instead of 4-20 mA, wire a 250 Ohm resistor in parallel
between the sensor output and ground.
®
0A
4 mA
20 mA
SENSOR OUTPUT
*Adjusted with Span Setting
Zero adjustment
The ZERO adjustment is used to set the sensor output current level from 3.5 to
4.5 mA when no current is present on the monitored conductor. Typical
setting is for 4 mA.
WIRING OPTION 1
WIRING OPTION 2
Span Adjustment
The SPAN adjustment is used to set the full-scale of the sensor to match to load
being monitored. It may be set to correlate the maximum 20 mA output to
AUTOMATION PANEL
COM 4-20 mA PWR
IN
OUT (12-30VDC)
EXTERNAL POWER
SUPPLY
COM
loads from 20 to 200 A. While operating maximum load, measure sensor
output current, adjust SPAN, such the the sensor output current correlates to
20 mA (or less, if desired).
+
SPECIFICATIONS
COM OUT PWR Span Zero
COM OUT PWR
COM
Span Zero
4-20 mA IN
AUTOMATION PANEL
Monitored Amperage Ratings...............200A continuous
Horsepower (h.p.) Ratings.............................0 to 100 h.p.
Sensor Supply Voltage..................................12 to 30 VDC
Supply Current.................................................30 mA max.
Frequency Range...............................10 to 80 Hz (+/- 1%)
Zero Adjustment...........................................3.5 to 4.5 mA
Span Adjustment..............................20 to 200A, full scale
Isolation...........................................................600VAC rms
Sealing....................................................N.E.M.A. 1, 12, 13
Temperature Range........................................-15º to 85ºC
Humidity Range............................0-95% non-condensing
Patent Pending
Literature ref. # L10130-1195