* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download startco - ElectricalManuals.net
Mercury-arc valve wikipedia , lookup
Voltage optimisation wikipedia , lookup
Fault tolerance wikipedia , lookup
Stray voltage wikipedia , lookup
Electrical substation wikipedia , lookup
Mains electricity wikipedia , lookup
Electronic engineering wikipedia , lookup
Alternating current wikipedia , lookup
Current source wikipedia , lookup
Surge protector wikipedia , lookup
Protective relay wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Ground (electricity) wikipedia , lookup
Circuit breaker wikipedia , lookup
Current mirror wikipedia , lookup
Residual-current device wikipedia , lookup
Buck converter wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
SE-105 STARTCO ENGINEERING LTD. 406 Jessop Avenue Saskatoon, Saskatchewan Canada S7N 2S5 Ph: (306) 373-5505 Fx: (306) 374-2245 www.startco.ca Additional information available at SE-105 www.startco.ca GROUND-FAULT GROUND-CHECK MONITOR The SE-105 is a combination ground-fault and ground-check monitor for resistance-grounded systems in non-hazardous applications. The ground-fault circuit is latching and the ground-check circuit is typically non-latching. One output contact is provided for contactor control, or for shunt or undervoltage operation in a breaker trip circuit. Ground-fault current is sensed by a CT200-series window-type current transformer. A trip level of 0.5, 2.0, or 4.0 A is switch selectable for use with a 5-, 15-, or 25-A grounding resistor. Trip time is adjustable from 0.1 to 2.0 seconds. The fail-safe ground-check circuit is validated by an end-of-line termination with a 5.6-volt Zener characteristic. The Zener characteristic clamps induced voltage and allows induced current to flow in the ground-check loop. Consequently, induced-ac-withstand capability, noise immunity, and open/short detection are independent of current in the phase conductors. TYPICAL APPLICATION CT200 LOAD GROUND UV 120 VAC L A GROUND FAULT B GC GC N L1 CAUTION: THE SE-105 IS NOT A LOCK-OUT DEVICE. FOLLOW LOCK-OUT PROCEDURES FOR MAINTENANCE. L2 RESET GROUND CHECK GF MODE 4.0 A SH 2.0 A 0.5 A UV POWER START GROUND CHECK F1 CT1 CT2 STOP G 5.6-V ZENER DIODE HOLD-IN G USE LOWCONTACT LEVEL CONTACTS 5.6-V ZENER DIODE ALTERNATE TERMINATION CIRCUIT FOR REMOTE CONTACTOR CONTROL GROUND-CHECK TERMINATION STARTCO ENGINEERING LTD. SW CI SE-105 GF-GC MONITOR GI GC G 1.0 0.1 2.0 GF TRIP TIME (s) STARTCO ENGINEERING LTD. SW CI F2 SE-105 GF-GC MONITOR GI GC GI G + F2 RED GROUND-FAULT INDICATOR GREEN GROUND-CHECK INDICATOR CI SW RESET SWITCH REMOTE INDICATION AND RESET TECHNICAL SPECIFICATIONS Supply: ac . . . . . . . . . . . . . . . 120 or 240 Vac (+10, -45%), 50/60 Hz, 10 VA ac/dc . . . . . . . . . . . . . . 120 Vdc (+40, -8%), 5 W 120 Vac (+10, -29%), 47 to 440 Hz, 5 VA Ground-Fault Circuit: CT Ratio . . . . . . . CT Input Burden . . . Trip Level* . . . . . . Frequency Response . . . . . . . . . . . . . . . . . . . . Trip Time. . . . . . Thermal Withstand* Trip-Level Accuracy Trip-Time Accuracy Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200:5 0.02 W 0.5, 2.0, or 4.0 A 25 to 400 Hz, 25 to 110 Hz with Option H 0.1 to 2.0 s 200 A Continuous, 2,500 A for 2 s +10, -20% 10% Latching * Currents referred to primary of CT200 for prospective ground-fault currents less than 4,000 A. Ground-Check Circuit: Open-Circuit Voltage . . Output Impedance. . . . Nominal Loop Current . . Induced-ac Withstand . . Fuse Rating (F2) . . . . Pull-In Time . . . . . . . Trip Time. . . . . . . . . Trip-Time Accuracy . . . GC-Loop Trip Resistance Operating Mode . . . . . Remote Indication: + . . . . . . . . . . . . . . . . 12 Vdc GI/CI . . . . . . . . . . . . . . Current Sink, 560 W Internal Dimensions: Height . . . . . . . . . . . . . 150 mm (5.9²) Width. . . . . . . . . . . . . . 109 mm (4.3²) Depth . . . . . . . . . . . . . 100 mm (4.0²) Shipping Weight . . . . . . . . . 1 kg (2.2 lb) Environment: Operating Temperature . . . . -40 to 60°C Storage Temperature . . . . . -55 to 80°C Humidity . . . . . . . . . . . . 85% Non-Condensing PWB Conformal Coating . . . . . MIL-1-46058 qualified, UL QMJU2 recognized ORDERING INFORMATION Option List (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Vdc 240 W 25 mA 25 Vac Continuous, 120 Vac for 3 s 0.5 A, 250 Vac, Time Delay 1.5 s 0.2 s (GC open), 0.5 s (GC to G short) +10, -30% 40 ± 10 W Non-Latching, Latching with Option L Output Relay: CSA/UL Contact Ratings . . . 1 mA to 4 A Resistive, 240 Vac or 28 Vdc Supplemental Contact Ratings: Make/carry 0.2 s . . . . . . 10 A Carry continuous . . . . . . 4 A Break: dc . . . . . . . . . . . . . 20 W resistive, 10 W inductive (L/R=0.04 s) ac . . . . . . . . . . . . . 960 VA resistive, 700 VA inductive (PF=0.4) Subject to maximums of 4 A and 240 V (ac or dc). Contact Configuration . . . . . N.O. (Form A) Fuse Rating (F1) . . . . . . . 4.0 A, 250 Vac, Time Delay Specifications are subject to change without notice. Startco Engineering Ltd. is not liable for contingent or consequential damages, or for expenses sustained as a result of incorrect application, incorrect adjustment, or a malfunction. Copyright © 2006. Printed in Canada. Publication: SE-105-D Revised: 0601 Printed: 0601 R C LR 53428 US SE-105 L Latching Ground-Check Trip 120-Vac Supply(2) H Harmonic Filtering E 240-Vac Supply D 120-Vac/dc Supply Each SE-105 is supplied with a 1N5339B termination device. (1) List options required in order shown above. (2) Standard, leave blank. Ground-Fault CT's: CT200 . . . . . . . . . . . . . 56 mm (2.2²) Window CT200L . . . . . . . . . . . . 89 mm (3.5²) Window Ground-Check Termination: 1N5339B. . . . . . . . . 1N4553B. . . . . . . . . SE-TA6 . . . . . . . . . SE-TA6A . . . . . . . . . Remote Indication RK-102. . . . . RK-105. . . . . RK-105I . . . . RK-13 . . . . . . . . . . . . . . . . . 5-W Axial Lead 50-W Stud Mount 50-W Assembly SE-134C Termination Assembly and Reset: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-mm Component Kit Indication-and-Reset Assembly Indication Assembly Relay Interface Module STARTCO ENGINEERING LTD. 406 Jessop Avenue, Saskatoon, Saskatchewan, Canada S7N 2S5 Phone: (306) 373-5505 Fax: (306) 374-2245 www.startco.ca