Download California Rule 21 LVRT - Northwest Solar Communities

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Mercury-arc valve wikipedia , lookup

Heterodyne wikipedia , lookup

Stepper motor wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electric power system wikipedia , lookup

Spark-gap transmitter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Utility frequency wikipedia , lookup

Ohm's law wikipedia , lookup

Power engineering wikipedia , lookup

Power inverter wikipedia , lookup

Electrical ballast wikipedia , lookup

Current source wikipedia , lookup

P–n diode wikipedia , lookup

Metadyne wikipedia , lookup

Schmitt trigger wikipedia , lookup

Three-phase electric power wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Rectifier wikipedia , lookup

Opto-isolator wikipedia , lookup

Electrical substation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Triode wikipedia , lookup

Power MOSFET wikipedia , lookup

Islanding wikipedia , lookup

Power electronics wikipedia , lookup

Voltage regulator wikipedia , lookup

History of electric power transmission wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Buck converter wikipedia , lookup

Surge protector wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
California Rule 21 SWIG
Possible Future Modifications to IEEE 1547
Michael Sheehan, P.E
IREC
[email protected]
PV Significant Trends
• Installed prices for distributed PV installations fell by at least 11 percent in 2013 and have fallen by 44
percent since 2009. The prices of some individual system components, especially modules, have fallen even
more. Lower prices increase consumer demand for solar installations.
• California was the most important market in 2013. Fifty-seven percent of U.S. capacity installed in 2013
occurred in the Golden State, and the capacity installed during 2013 was 161 percent greater than what was
installed in 2012
• Residential capacity installed in 2013 grew by 68 percent in the U.S., fueled by the increasing use of
leases and third-party ownership of these systems. Over 145,000 residential PV systems were installed
during the year.
• Utility sector capacity installed grew by 47 percent. Ten PV installations, each larger than 100 MWDC,
were completed in 2013.
• Hawaii had the highest per capita installed capacity of PV systems. More than 75 percent of gridconnected PV system capacity installed in 2013 was concentrated in California, Arizona and North
Carolina.
Opposite Points Of View
• Distribution System – IEEE 1547
Domain
• Bulk generation and voltage
support is “infinite” – who
cares!
• Main concern is protection
coordination, power quality, and
safety during and after
distribution system events
• DG must trip outside specified
voltage vs. time and frequency
vs. time envelope
 Bulk Power System – NERC Domain
 Distributed generation capacity is
too small – who cares!
 Main concern is maintaining
frequency and local voltage (grid
security) during and after
transmission system events
 Generators must not trip inside
specified voltage vs. time and
frequency vs. time envelope
As DG penetration increases, these opposing points of
view must be reconciled.
Problem Statement in Words
Rather than VRT and FRT provisions, the existing IEEE
Standard 1547 contains “must-trip” provisions for offnominal voltage and frequency that raise the possibility
of compounding transmission contingencies with
sympathetic loss of significant amounts of distributed
generation.
Transmission Ramp Events
CAISO July 3, 2011, 65% drop in solar production
The California Duck
Low Voltage for 345 kV Fault in Massachusetts with all DG on
California Smart Inverter WG Phase 1
Seven Autonomous Functions
 Support anti-islanding to trip off under extended anomalous conditions,
coordinated with the following functions.
 Provide ride-through of low/high voltage excursions beyond normal limits.
 Provide ride-through of low/high frequency excursions beyond normal limits.
 Provide volt/var control through dynamic reactive power injection through
autonomous responses to local voltage measurements.
 Define default and emergency ramp rates as well as high and low limits.
 Provide reactive power by a fixed power factor.
 Reconnect by “soft-start” methods (e.g. ramping and/or random time within a
window).
Voltage IEEE 1547 vs. NERC PRC-024
1.4
1.3
May Trip
Must Trip
IEEE 1547
PRC-024
1.2
1.1
1.0
Voltage (pu)
0.9
0.8
0.7
0.6
Continuous
Must Not Trip
…unless it is a stability issue
May Trip
…but void nuisance tripping
0.5
0.4
0.3
0.2
Must Trip
0.1
0.0
0.1
0.2
0.3
0.4 0.5 .6 .7 .8 .9 1
Time (sec)
2
3
4
5
6
7 8 9 10
SIWG Remain Connected Concept
Proposed Voltage Ride-Through Default Values
Ride-through region for Voltage
Hawaiian Electric New Requirements LVRT and LFRT
New Lexicon
Trip: Cease to energize or disconnect from the Area EPS due to an Area EPS disturbance. Following a trip, the IDER must delay re-energization or reconnection for a preset period of time once the voltage and frequency of the
Area EPS are within normal ranges (voltage within ANSI C84.1-1995 Table 1 Range B and frequency within 59.3 Hz
to 60.5 Hz).
Momentary cessation: The I-DER momentarily ceases to energize the Area EPS. The I-DER is allowed to reenergize the Area EPS without any intentional reconnection delay once voltage exits the momentary cessation
region and enters a permissive operation region or continuous operation region.
Permissive operation: The I-DER is allowed, but not required, to operate at any current level.
Continuous operation: The I-DER operates indefinitely at full available current without tripping. Any functions
that protect the I-DER from damage may operate as needed. Any functions that reduce current availability may
operate as necessary.
Nominal: Standard frequency and voltage
Mandatory operation: the I-DER operates at full available current without tripping during Area EPS disturbances
outside the region of continuous operation. Any functions that reduce current availability may operate as
necessary.
Thank You!
The California Rule 21 tariffs are available at the following link.
http://www.cpuc.ca.gov/PUC/energy/rule21.htm