* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download KSR Electrode Relay Type ER230 and ER24
Analog-to-digital converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Regenerative circuit wikipedia , lookup
Integrating ADC wikipedia , lookup
Radio transmitter design wikipedia , lookup
Nanogenerator wikipedia , lookup
Two-port network wikipedia , lookup
Power MOSFET wikipedia , lookup
Surge protector wikipedia , lookup
Transistor–transistor logic wikipedia , lookup
Wilson current mirror wikipedia , lookup
Voltage regulator wikipedia , lookup
Valve audio amplifier technical specification wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Schmitt trigger wikipedia , lookup
Operational amplifier wikipedia , lookup
Power electronics wikipedia , lookup
Current mirror wikipedia , lookup
Switched-mode power supply wikipedia , lookup
KSR Electrode Relay Type ER230 and ER24 General description KSR Electrode relays type ER230 and ER24 operate on the conductive measurement principle and can be used in conjunction with KSR Rod electrodes to monitor and control liquid levels of electrically conductive media such as water, caustic solutions or acids. They have a protected low voltage control circuit to VDE 0100 part 410. 1(I) 2 (min) 3 (max) The electrode relays provide an AC measuring voltage to the electrodes and react to the small alternating current at the electrode tip, generated upon contact with the conductive medium. The controllers are voltage and temperature stabilised and guarantee a defined switch behaviour. A holding contact allows the units to be used as minmax controllers. As conductivity can vary from liquid to liquid, the response sensitivity of the relay units is adjustable. U green grün Via the relay outputs, the switch signals can be forwarded to other evaluating circuits or instruments. Power supply/output , power supply/input and input/output are galvanically isolated to DIN 106, rated insulation voltage of 253Veff. Open circuit current principle In the open circuit current principle the relay energises when the liquid reaches the electrode. Closed circuit current principle Technical features In the closed circuit current principle the relay energises immediately on power up. It de-energises, when the liquid reaches the electrode. ♦ protected low voltage control circuit to VDE 0100 part 410 ♦ Min-Max-Control ♦ open circuit current / closed circuit current – user selectable U 7 9 8 output Ausgang U 11 12 11(+) 12(-) supply voltage Speisespannung ER230 ER24 ER230 ER24 Selection of operating mode output relay detail front panel Ausschnitt Frontplatte S1 I II 1 Relais relay energised angezogen 0 - Signal Relais relay de-energised abgefallen input Eingang 3 1 II 1 - Signal 3 detail front panel Ausschnitt Frontplatte I output Ausgang input Eingang 3 1 S1 1004-2 U U yellow gelb ~ 1 output Ausgang 0 - Signal Relais relay energised angezogen 1 - Signal Relais relay de-energised abgefallen 3 Dimensions B 20 mm H 105 mm T 115 mm LED yellow: LED gelb relay output 1 Relaisausgang 1 4 2 5 3 6 LED LED green: grün power on Speisespannung Schalter switch S1 S1 potentiometer Potentiometer 2 7 8 9 10 11 12 ER230 ER24 Technical data Supply supply voltage power consumption Input/control circuit response sensitivity max. voltage max. current min- /max- control on- / off- control terminals 11(+) , 12(-) terminals 1 , 2 and 3 Output terminals 7 , 8 and 9 contact rating AC contact rating DC delay time: energising / de-energising switch S1 230V AC, 48Hz ... 62Hz ≤ 0.8W 24V DC 1 (mass/ground) ; 2 (min.) ; 3 (max.) 5 kOhm ... 150 kOhm adjustable 10V AC (approx.. 1 Hz) 5mA terminals 1 , 2 and 3 terminals 1 and 3 1 relay output (changeover contact) volt-free 250V / 2A / cosϕ > 0,7 40V / 2A / resistance load approx. 1s / approx. 1s I open circuit current II closed circuit current Transfer characteristics switching frequency Galvanic isolation power supply / output power supply / input input / output Environmental conditions operating temperature type of protection Mechanical data design mounting connection terminals weight ≤ 10Hz galvanic isolation to DIN 106 rated insulation voltage 253Veff -25°C ... +65°C IP 20 modular terminal housing in Makrolon, flammability class UL94: V - 0 snap/clip onto standard 35mm rail or screw mounted via 2 screws self-opening instrument terminals max. 2.5mm² approx. 110g 1004-2 3