08/12
DS006 – Issue 1
CERIAN High Efficiency Module
CERIAN Module
Description
CERIAN modules provide
maintained emergency operation for
T8 lamps from 3, 4 or 5 cell NiCd
batteries.
CERIAN modules are fitted with four
pole relays to switch all four lamp
connections from the ballast to the
inverter.
The ballast hold off relay is to switch
the ballast off during emergency
lighting test.
Product Features








High Efficiency rectified output optimised for T8 lamps
Compact size allows simple installation
TM
AutoTest versions fully compliant with IEC 62034
TM
AutoTest versions with DALI and Potential Free options
Deep Discharge Protection fitted
ENEC Approved – NON-AUTOTEST ONLY
3 Year Warranty
1 or 3 hour variants available
CERIAN High Efficiency Module
CERIAN Module
Technology
Part Number
Deep Discharge Protection
All modules are fitted with deep
discharge protection (DDP) as
standard.
Module
SR664/M3
SR664/M1
Type
3x 4Ah
3x 1.5Ah
Lamps
T8 18,36W
SR665/M3
SR665/M1
4x 4Ah
4x 1.5Ah
T8 18, 36,
58W
SR666/M3
SR666/M1
5x 4Ah
5x 1.5Ah
T8 70W
Isolating Transformer
Mackwell transformers comply with
relevant standards and incorporate
a re-settable thermal device to
protect the transformer from
excessive overload conditions.
Battery Charger
Provides sufficient charge to
achieve rated duration from 24 hour
charge.
Voltage Sensing Circuit
The AC power supply is sensed so
that switching occurs at between
60% and 85% of the nominal mains
supply.
Indicator
The LED indicator is illuminated
when a charge is flowing to the
cells. Flexible 1x0.6mm high
temperature orange and pink leads
connect the indicator to the module.
The indicator requires a 8mm hole.
The indicator supplied with
AutoTest™ modules is bi-colour
red and green, with red and green
wires.
Specifications
Module Dimension
Can Type
V0 Plastic
Width
44mm
Height
35mm
Length
150mm
Fixing Centres
140mm
Weight
250g
Mains Input
Standard 240V± 6% 50/60Hz.
AutoTestTM Variants
ASR664/M3 3x 4Ah
ASR664/M1 3x 1.5Ah
T8 18,36W
Data quoted at 240V input: Other
voltages and frequencies available.
ASR665/M3 4x 4Ah
ASR665/M1 4x 1.5Ah
T8 18,36,
58W
Mains Current
80mA max – AutoTest
40mA max – Non AutoTest
ASR666/M3 5x 4Ah
ASR666/M1 5x 1.5Ah
T8 70W
Temperature
0 to +50°C ambient, maximum case
The AutoTestTM versions comply fully with temperature 70°C at Tc point.
IEC 62034. For DALI versions add suffix
/D1, for Potential Free add suffix /P.
Battery Charge Current
Please note that for non-DALI AutoTest™
products, the start times of the tests are
set automatically to ensure random
testing of the units at times of minimum
risk. As a consequence tests may occur
at any time, and caution should be
exercised in situations where this may be
inconvenient.
260mA nominal for 3hr duration.
100mA nominal for 1hr duration.
Battery Discharge Current
1.05 A nominal.
Battery
NiCd only
Caution:
REVERSING BATTERY POLARITY WILL Lamp performance can be affected
CAUSE DAMAGE
by lead length. Lamp wires should be
kept to a minimum length.
Do not insulation test this product.
The rectified output of these modules
may lead to mercury migration of the
lamp
We reserve the right to alter
specifications without prior notice.