Download 3306 Prime Power

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
3306 Prime Power
Generator Set
200 kVA
250 kVA
160 kW 200 kW
Leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost‐effectiveness.
‰Application Engineering
‰Performance Analysis
‰Captive Power Feasbility
‰Monitoring & Field Services
‰Plant Engineering
‰Annual Service Contract ‰Load Analysis & Genset sizing
‰Commissioning Services
‰Installation Services
‰On‐site Repair Services
‰Turnkey Supply & Installation
‰Customer support Agreement
Engine
AC Generator
ƒCaterpillar 3306B DITA, 4 Stroke, 6 Cylinders, Water Cooled Diesel Engine Prime Rated at 1500 RPM
ƒReliable, Rugged, Durable engine with longer life & consistent performance
ƒLong‐term Fuel Economy
ƒCertified to meet emission regulations in India
ƒDesigned & manufactured for caterpillar engines
ƒClass H insulation & temperature rise
ƒAREP windings for better short‐circuit capabilities
ƒSingle bearing, self‐excited & self regulated
ƒBrushless generator with automatic voltage regulator
ƒMeeting Indian & internal standards
Standard Scope
Acoustic Enclosure
ƒSheet steel fabricated for outdoor application
ƒNoise reduction lining & insulation inside enclosure
ƒIntegrating louvers for ventilation air inlet & outlet
ƒAccess doors for operation & maintenance
A
d
f
ti & i t
ƒOversized for easy maintenance
ƒWeatherproof paint
ƒCertified to meet CPCB noise regulations in India
ƒInternal illumination for maintenance & operations
ƒEngine day fuel tank
ƒGenset anti‐vibration mountings
ƒAfter cooler
ƒBattery, starting system 24 VDC
ƒCaterpillar Governor
ƒCharging alternator
h
l
ƒCoolant conditioner
ƒCoolant drain line with valve
ƒCoolant level sensor
ƒCrankcase breather
ƒFlexible fuel lines
ƒFuel transfer pump
ƒFumes disposal
ƒInstrument panel engine
ƒInstrument panel engine
ƒLube oil level indicator
ƒLubrication oil in sump & filter
ƒOil drain with valve
ƒPrimary & secondary fuel filters
ƒPriming pump hand‐operated
ƒRadiator fan & guard
ƒSafety shut‐offs
ƒAir cleaner‐heavy duty (optional)
y
y( p
)
ƒHeat exchanger cooling (optional)
Control Panel
Control
Panel
ƒSheet steel enclosed, vertical floor mounting
ƒCircuit breaker with protection
ƒMeters, lamps, switches ƒCurrent transformers for metering
ƒBusbars, power & control terminations
ƒSpecial panels (optional for custom needs)
ƒAuto mains‐failure panels (optional)
ƒParalleling / Synchronization (optional)
ONE SOURCE FOR RELIABLE AND UNINTERRUPTED POWER
3306 Prime Power
Generator Set
200 kVA
250 kVA
TECHNICAL DATA SHEET
PACKAGE GENSET
Prime Power Rating with radiator fan
Voltage, Phase, Hz
Package size – Length X Width X Height
Weight of complete package
ekVA
3306 DITA-GP-2
200
3306 DITA-GP-4
250
ekW
160
200
VAC/Hz
mms
kGs
415 VAC, 3 Ph, 50 HZ
4800 X 1700 X 2200
3500
ENGINE
415 VAC, 3 Ph, 50 Hz
5500 X 2100 X 2500
4500
3306 DITA-GP-2
Nos. Of Cylinders / Aspirations
3306 DITA-GP-4
6 Cyl / Turbocharged After-cooled
Bore X Stroke, Displacement, Compression Ratio
121 X 152 mms, 10.5Ltrs, 15:1
Fuel System:
Fuel Consumption with Fan @100% Rating
57.2
@ 75% Rating
Ltrs/Hr
Ltrs/Hr
45.2
Fuel Consumption with Fan
34
42.4
Fuel Consumption with Fan
Day Diesel Fuel Tank Capacity
@ 50% Rating
Ltrs/Hr
23.9
29.5
Ltrs
450
450
Cooling System:
Ambient Air Temperature (Design)
Engine Coolant Capacity with Radiator
Deg
eg C
50
50
Ltrs
48
50.9
Ltrs/Min
135
135
Deg C
36/48
36/48
Ltrs.
27.4
27.4
Exhaust Stack Gas Temperature
Deg C
519.5
485
Exhaust Gas Flow Rate
M3/Min
36 4
36.4
39 6
39.6
kPa
6.7
6.7
mms
152.4
152.4
M3/Min
13
14.9
Cooling Water Flow (HE Cooled Option)
Cooling Water Inlet / Outlet Temperature
Lube Oil System:
Lube Oil Sump Capacity with Filter
Exhaust System:
Exhaust System Back-pressure at engine outlet (max.)
Exhaust Flange (Outlet Pipe / Muffler) Size
Intake Air System:
Combustion Air Inlet Flow Rate
Heat Rejections:
Heat Rejection to Coolant – Total
kW
101
129
Heat Rejection to Exhaust
kW
160
174
kW
44.24
54.75
Heat Rejection to Atmosphere from Engine & Generator
AC Generator
kVA
200
Enclosure Protection
Nos. of Bearings
Insulation & Temperature Rise
250
IP23
IP23
Single
Single
Class H
Class H
Top with Terminals
Top with Terminals
G
Generator
t Cooling
C li
I t
Internal,
l Fan
F
I t
Internal,
l Fan
F
Voltage Regulation
+/- 1%
+/- 1%
Total Harmonic Distortion
< 3%
< 3%
Telephonic Influence Factor
< 2%
< 2%
Terminal Box
Conditions & Definitions
Prime: Output available with varying loads for an
unlimited time. Prime power in accordance with ISO
8528. 10% overload power in accordance with
ISO3046/1, BS5514, DIN6271, AS2789.
1, Taratolla Road, Garden Reach,
Ratings: Ratings are based on SAE J1349 standard
conditions. These ratings also apply at ISO 3046/1,
BS5514 & DIN6271 standard conditions. ISO 3046
tolerances shall apply
TIL Limited
Kolkata 700024
Tel: (033) 6633 2000/2845
Fax:(033) 24693731
www.tilindia.in
Mail: [email protected]
Fuel: Fuel rates are based on fuel oil of 35 Deg
API (16 Deg C or 60 Deg F) gravity having an
LHV of 42,780 kJ/kG (18,390 Btu/lb) when used
at 29 deg C (85 Deg F) and weighing 850
G /Lt .
Gms/Ltr
Plot 11, Site-IV, Industrial Area,
Sahibabad, Ghaziabad 101010
Tel: (0120) 2777945
Fax:(0120) 2770365
Toll free: 18003453356