□DC130-12 344mm 172mm 50mm 283mm 262mm 19mm 278mm Terminal 1:1 NEGATIVE POSITIVE 19.5 17 1:9 60mm 17 1:9 19.5 16 17.2 ?19.1 Specifications Discharge characteristics 77 ℉(25 ℃) Nominal Voltage 12V Rated Capacity (20 hour rate) 130AH Total Height Height 280mm(11.02inches) Length 344mm(13.54inches) Width 172mm(6.77inches) Weight Temperature:25℉(77℉) 13.0 12.0 Terminal voltage Dimension (V) 12V Battery 283mm(11.14inches) (with terminals) 11.0 9.0 390A Internal Resistance Capacity affected by Temperature (20 hour rate) Self-Discharge 77℉(25℃) 130AH 10 hour rate (11.7A to 10.5Volts) 117AH 5 hour rate (21.4A to 10.2Volts) 107AH Full charged 77℉(25℃) 3.6mΩ 104℉(40℃) 102% 77℉(25℃) 100% 32℉(0℃) 85% 5℉(-15℃) 65% Capacity after 3 month storage 91% Capacity after 6 month storage 82% Capacity after 12 month storage 64% Standard Terminal AP Max. Discharge Current 77℉(25℃) 1400A (5s) Cranking Amps Cold Cranking Amps Performance 5 10 minutes 60 20 2 5 hours Discharge time Duration of discharge vs. Discharge current 104℉(40℉) 77℉(25℉) 32℉(0℉) 5℉(-15℉) 950A (30-sec amps to 7.2V @ 32°F (0°C) Cranking 2 Duration of discharge 77℉(25℃) 20 hour rate (6.5A to 10.5Volts) 130A 75.4A 8.0 Approx.43.1kg (94.82Ibs) 1 Capacity 21.4A 11.7A 6.5A 10.0 Characteristics 790A (30-sec amps to 7.2V @ 0°F (-18°C) Reserve Capacity @ 25Amps 250Min (Minutes to 10.5V at 80℉(27℃) @ 75Amps 60Min Charging (Constant Voltage) ?17.9 Cycle Initial Charging Current 26A Or Small 14.4V~14.9V/77℉(25℃) Float 13.6V~13.8V/77℉(25℃) Discharge current(A) Constant Current Discharge Rating Amperes @ 77℉(25℃) Cut off voltage V/cell 15M 30M 45M 1H 2H 3H 5H 8H 10H 12H 20H 24H 1.75V 220 130 93 73.9 42.6 30.6 21.0 14.13 11.7 10.07 6.5 5.45 FULLRIVER DC BATTERIES This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specification are subject to modification without notice. Contact Fullriver for the latest information. 10 20