Download Basic Series 40 Information

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

Mains electricity wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Alternating current wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Resilient control systems wikipedia , lookup

Relay wikipedia , lookup

Electric power system wikipedia , lookup

Power engineering wikipedia , lookup

Power over Ethernet wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Distribution management system wikipedia , lookup

Rectiverter wikipedia , lookup

Electronic musical instrument wikipedia , lookup

Control system wikipedia , lookup

Transcript
Cimco Electronics, Inc.
PHONE (724) 528-9559
FAX
(724) 528-1108
P. O. Box 248; 26 Main St.
West Middlesex, PA 16159
MODEL 40
DESCRIPTION AND INSTRUCTIONS
May 1, 1996
1. GENERAL DESCRIPTION
1. MONITORS ONE SENSOR
2. NON-MAGNETIC TYPE E THERMOCOUPLE
3. MICRO-PROCESSOR BASED LOGIC CONTROL
4. CARBON STEEL FACE-PLATE AND INSTRUMENT BOX
5. RELAY OUTPUTS
1. LOCAL ALARM-FORM A (FAIL SAFE-open T/C or loss of power)
2. REMOTE ALARM-FORM C (FAIL SAFE-open T/C or loss of power)
3. TRIP -FORM C
4. FAN POWER-FORM A; (FAIL SAFE-open T/C or loss of power)
RELAY CONTACT CARRIES SAME VOLTAGE AS APPLIED TO TERMINAL 7 & 8.
2. DISPLAY
1. THREE LED DIGITS
2. RANGE IS 250 DEGREES CENTIGRADE
3. ACCURACY IS PLUS/MINUS ONE DEGREE CENTIGRADE
3. OPERATOR CONTROL PANEL
1. STATUS INDICATORS
1. LED
2. POWER ON IS GREEN, FANS ON IS AMBER/YELLOW, ALARM AND TRIP ARE RED
2. OPERATOR CONTROLS
1. PRESS TO READ MAXIMUM TEMPERATURE MEMORY
2. PRESS TO ERASE MAXIMUM TEMPERATURE MEMORY
3. PRESS TO TEST ALARM RELAYS AND REMOTE CIRCUITRY
4. PRESS TO SILENCE LOCAL ALARM
REMOTE ALARM REMAINS ON UNTIL ALARM CONDITION CLEARS.
5. FAN MODE CONTROLS
1. INSTRUMENT STARTS UP IN AUTOMATIC FAN MODE CONTROL
2. GREEN LED INDICATES AUTOMATIC MODE CONTROL IS ON.
3. PRESS MANUAL ON CONTROL TO ENERGIZE FANS CONTINUOUSLY
4. PRESS MANUAL OFF CONTROL TO DE-ENERGIZE FAN POWER.
3. CONTROL PANEL COVER
1. LEXAN
2. GRAY WITH BLACK TRIM
3. WATER PROOF COVER
4. SMOOTH FACE-PLATE
1. NO SWITCHES EXTEND OUT OF THE INSTRUMENT FACE-PLATE
2. NO LIGHTS EXTEND OUT OF THE INSTRUMENT FACE-PLATE.
4. CONNECTION INSTRUCTIONS
1. LOCATED ON BACK SIDE OF THE INSTRUMENT
2. CONNECT TYPE E THERMOCOUPLE ON LEFT SIDE-RED LEAD IS NEGATIVE.
3. CONNECT ALARM LEADS
4. CONNECT FAN LEADS
1. CONTACT ON TERMINAL 10 CONNECTS TO TERMINAL 7 IN SIDE THE INSTRUMENT.
2. TERMINAL 8 AND 9 ARE CONNECTED TOGETHER IN SIDE THE INSTRUMENT.
5. CONNECT POWER LEADS TO TERMINAL 7 AND 8.
6. CONTACT RATINGS:
1. NORMALLY OPEN; 20 AMPS RESISTIVE; 1 HP AT 120 VAC, 2 HP AT 240 VAC
2. NORMALLY CLOSED; 10 AMPS RESISTIVE
5. SET-POINT ADJUSTMENTS
1. ORDER EACH INSTRUMENT WITH DESIRED SET-POINTS.
2. CONTACT CIMCO FOR DETAILED INSTRUCTIONS.
POWER ON
FANS ON
ALARM
TRIP
OPERATING STATUS
MAXIMUM
TEMPERATURE
MEMORY
READ
RESET
PRESS
TO TEST
ALARM
FAN MODE
CONTROL
AUTOMATIC
WINDING
TEMPERATURE
DEGREES CENTIGRADE
MANUAL ON
PRESS
TO SILENCE
ALARM
TEMPERATURE
CONTROL SYSTEM
SERIES 40
MANUAL OFF
DANGER
HAZARD OF ELECTRICAL
SHOCK OR BURN
TURN OFF POWER SUPPLYING
THIS EQUIPMENT BEFORE
WORKING INSIDE
HIGH VOLTAGE
FOUR MOUNTING HOLES (0.28” SQUARE) ON 6.5” SQUARE
STEEL FACEPLATE IS 7.5” SQUARE
REF. DWG. 12-18-98-A
SUB 1: AREA CODE, 12-18-98
FACE-PLATE
SERIES 40
MAY 29, 1996
DRAWING 5-29-96-A
SCALE 1 = 1
CIMCO ELECTRONICS, INC.
26 MAIN ST.; PO BOX 248
WEST MIDDLESEX, PA 16159
PHONE 724-528-9559
FAX 724-528-1108
Cimco Electronics, Inc.
PHONE (724) 528-9559
FAX
(724) 528-1108
P. O. Box 248; 26 Main St.
West Middlesex, PA 16159
May 1, 1996
SERIES 40
CHANGE SET-POINT INSTRUCTIONS
NEVER CHANGE SET-POINTS WITHOUT APPROVAL
FROM TRANSFORMER MANUFACTURER.
1.
APPLY MILLI-VOLT SOURCE TO THERMOCOUPLE INPUT TERMINALS.
CIMCO SELLS BATTERY POWERED (1.5 VDC) MILLI-VOLT SOURCES FOR
FIFTY DOLLARS.
2.
ENERGIZE INSTRUMENT
3.
ADJUST MILLI-VOLT SOURCE UNTIL THE DISPLAY INDICATES THE DESIRED
TEMPERATURE
FOR NEW SET-POINT.
4.
ADJUSTMENT ACCESS HOLES ARE LABELED ON TOP OF INSTRUMENT.
5.
USE SMALL FLAT-TIP SCREWDRIVER. ROTATE ADJUSTMENTS UNTIL THE
FANS ON, ALARM,
OR TRIP LIGHTS ENERGIZE.
1. COUNTER-CLOCKWISE ROTATION RAISES SET-POINTS.
2. CLOCKWISE ROTATION LOWERS SET-POINTS.
6.
RELAY OFF SET-POINTS ARE FIXED AT TIME OF MANUFACTURER.
1. FAN “DEAD BAND” IS TWENTY DEGREES CENTIGRADE.
2. ALARM “DEAD BAND” IS FIVE DEGREES CENTIGRADE.
3. TRIP “DEAD BAND” IS FIVE DEGREES CENTIGRADE.
TEMPERATURE SENSOR
+
1
2
MUST BE “TYPE E”
THERMOCOUPLE ONLY
RED THERMOCOUPLE
LEAD MUST CONNECT
TO NEGATIVE TERMINAL
CIMCO ELECTRONICS, INC.
(724) 528-9559
MADE IN USA
MODEL 40-__________
SERIAL NO. ____________
RELAY NOTATION IS INSTRUMENT ENERGIZED CONDITION.
ALL RELAY CONTACTS ARE RATED
LOCAL
20 AMPS NORMALLY OPEN AND
ALARM
10 AMPS NORMALLY CLOSED
RESISTIVE LOAD AT 120 OR 240 VAC.
REMOTE
______ VAC ______ VAC
SYSTEM
ALARM
FAN
TRIP
POWER IN
3
GROUND
POWER OUT
T-7
4
5
6
7
8
9
10
5.5”
11
5.5”
REAR VIEW
NOTES:
1. REFERENCE CIMCO DRAWING 3-18-96-A
2. MOUNTING HOLE SIZE MUST BE 5.75 MIN/6.0 MAX INCH SQUARE.
3. MOUNTING HOLE MUST BE CENTERED WITH 4 (0.281” SQ.) MOUNTING HOLES.
4. BACK BOX IS 2.5 “ DEEP.
5. BACK BOX IS CARBON STEEL.
BACK BOX
SERIES 40
MARCH 18, 1996
DRAWING 3-18-96-B
SCALE 1 = 1
CIMCO ELECTRONICS, INC.
26 MAIN ST.; P. O. BOX 248
WEST MIDDLESEX, PA 16159
PHONE 724-528-9559
FAX 724-528-1108