* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Digital Turbine Controller DTC 300
Survey
Document related concepts
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Wassim Michael Haddad wikipedia , lookup
Control theory wikipedia , lookup
Distribution management system wikipedia , lookup
Resilient control systems wikipedia , lookup
Transcript
Digital Turbine Controller DTC 300 A new generation of digital turbine controllers guarantee safe, reliable and economic power plant operation • Easy handling and clear indications at the HMI-display are the most significant features of the new digital turbine governors DTC 300. • Remote control and fault analysis grant a reliable operation in unmanned power stations. • Remote servicing enables the technicians of Kössler to investigate and eliminate faults as well as doing revisions in programming according specific client needs, fast and economically directly out from the office. • The new controllers are equipped with several standardized interfaces and therefore can be implemented easily into an overall power plant control system. Governor functions: Basic equipment: Operation modes: • Start automatic • Plant operation paralleled to grid: - Opening control 1) - Head water level control 1) - Flow control 2) - Power control 2) • Plant operation at isolated grid: (Isolated mode) : - Isolated operation control 3) - Base load control 3) • Stop automatic with Normaland Quick-Shutdown functions • PLC-System with SIMATIC CPU • Supply voltage 24 VDC • Digital In- and Output modules • Analogue In- and Output modules • Fast counter inputs for speed evaluation • HMI – operator panel • Profibus and Ethernet interface • Ready made connection cables • Water level probe • Ferrostatic sensor for speed detection at a tooth wheel The DTC 300 can be operated in remote as well as in local mode • Remote control : - Automatic operation - Opening control • Local Control : - Automatic operation - Opening control - Manual mode - Emergency mode for service and fault investigations 1) Basic version 2) Additional metering equipment necessary 3) Option Functions for automatic start up and paralleled operation Speed control: 1) The speed governor accelerates the turbine along a parameterable ramp up to nominal speed and then controls the rotary frequency of the set during synchronizing according the commands of an automatic synchronizer or manual up- / down commands. Opening control: 1) Remote control: The opening governor controls the position of the wicket gate or the nozzles according the setpoint given from the power plant control system. Local control: The DTC 300 controls the position of the wicket gate or the nozzles according the default setpoint at the HMI operator panel. Head water level control: 1) The water level at the head pond is controlled. The actual water level value is evaluated by means of a level probe. The nominal water level setpoint can be set on the HMI operator panel or from the power plant control system. Flow control: 2) The water flow in the penstock is controlled. The actual water flow value is evaluated by means of a flow meter 3). The nominal water flow setpoint can be set on the HMI operator panel or from the power plant control system. Power control: 2) The generator output power is controlled. The actual power value is evaluated by means of a transducer 3) or taken over from common control system. The nominal power setpoint can be set on the HMI operator panel or from the power plant control system. 1) Basic version 2) Additional metering equipment necessary 3) Option