Utility Issues with CSST Gas Piping October 2014 Utility Issues with CSST Gas Piping Advantages of CSST Long continuous runs Few joints Smaller installation crew Faster installation time Only simple hand tools required No threading machines/mess Safer interaction with structure Utility Issues with CSST Gas Piping Standard Yellow Arc-Resistant Black Utility Issues with CSST Gas Piping Protection from Lightning Lightning protection system Bonding of piping to grounding electrode system Arc resistant protective jacket Utility Issues with CSST Gas Piping Lightning Damage Total lightning strikes in US per year: 43,500,000* No house, equipment or material safe from direct lightning strike Most claims from indirect strikes [*USPLN: 2005-2009] Utility Issues with CSST Gas Piping Lightning Pathways Utility Issues with CSST Gas Piping What are the root causes? Changes in house construction/size/location Loss of metal piping Loss of copper wire for communications Loss of metal conduit for electric wiring Utility Issues with CSST Gas Piping Unintended Consequences Metallic appliance flue (instead of brick/clay chimneys) which rise above the roofline. Metal vent acts like lightning rod not directly connected to the electrical grounding system. Utility Issues with CSST Gas Piping Lightning does not discriminate. It seeks all pathways to ground. It will damage all mechanical/electrical systems. Utility Issues with CSST Gas Piping Arcing damage impacts all metallic systems including wiring and all gas piping materials. Damage not due to lightning induced voltage levels, but due to large differential in voltage potential. Utility Issues with CSST Gas Piping Underground PE Piping Fires Utility Issues with CSST Gas Piping Model and State Code Conflicts • National Fuel Gas Code • International Fuel Gas Code • National Electrical Code • Different editions enforced • 50 different State Building Codes • Utility facility code - NFPA 54 Utility Issues with CSST Gas Piping Manufacturer’s Design and Installation Guide 1. Used in conjunction with state regulations, code and local practices 2. Defer to Design Guide if no coverage in state or local regulations 3. If conflict exists, then more stringent practice applies 4. Updated frequently Utility Issues with CSST Gas Piping NEC: Equipment Grounding Conductor All gas piping electrically continuous EGC sized to protect against ground faults EGC sized based on branch circuit 12/14 AWG wire not designed to handle lightning voltage Utility Issues with CSST Gas Piping 2009 & 2012 IFGC/UPC/NFGC: Bonding CSST gas piping systems shall be bonded to the electrical service grounding electrode system. The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall not be smaller than 6 AWG copper wire or equivalent. Existing steel pipe or copper tubing gas piping systems which are modified by adding one or more segments of CSST of any length shall be bonded in accordance with this section. Utility Issues with CSST Gas Piping Bonding Clamp* Attachment * Bonding Clamps listed to UL 467 Utility Issues with CSST Gas Piping Bonding Clamp* Attachment * Clamp listed to UL 467 for CSST Utility Issues with CSST Gas Piping Bonding Clamp Attachment Never place bonding clamp directly on CSST. Utility Issues with CSST Gas Piping Bonding Requirements Gas piping systems that contain one or more segments of CSST shall be bonded. Utility Issues with CSST Gas Piping Bonding Connections Gas piping shall not be used as a grounding electrode Utility Issues with CSST Gas Piping Bond Connection to Grounding System Utility Issues with CSST Gas Piping Bond to Intersystem Termination or Panel Box Utility Issues with CSST Gas Piping Bonding Conductor Sizing Conductor at least 6 AWG copper or 4 AWG aluminum Conductor single or multi-strand Conductor length and gauge are inter-related, but length is not specified in the NEC Utility Issues with CSST Gas Piping No Separate Gas Grounding Electrode Gas piping shall not be used as a grounding conductor or electrode. Bonding clamp only on customer’s side of the meter. Only one grounding system for the house. Utility Issues with CSST Gas Piping Underground PE Piping Copper tracer wire will be energized and arc to PE Tracer wire can energize house piping when attached to riser Increase and maintain minimum physical separation distance (6-in) Utility Issues with CSST Gas Piping Daisy Chaining of Meters Utility Issues with CSST Gas Piping Bonding Effectiveness Research Impact on 2015 NFGC • • • • • • • • Bond is effective (no arcing damage to CSST) Indirect and partial direct lightning strikes Lightning energy 8/20 and 10/350 up to 10kA No damage for long conductors (up to 150-ft) No arcing for shorter conductors (< 75-ft) Lightning entry point varied Clamp location not significant factor Multiple bonding not justified for SF house Utility Issues with CSST Gas Piping 2015 NFPA 54 Code Requirements • • • • • • Bonding is required for CSST Clamp located anywhere Single point of attachment Conductor of 75-ft or less Required for new and retrofit Bond all grounding electrodes Utility Issues with CSST Gas Piping ANSI LC-1-2014 CSST Standard • New listing criteria for arc-resistant jacket • Yellow and black jacket color • Installer training program 29 Utility Issues with CSST Gas Piping Arc-Resistant Jackets • • • • • Conductive jacket Arc energy absorbed Listed to CSA LC-1 Standard Protection up to 5 Coulombs Approved as alternate method WARDFLEX II 30 Utility Issues with CSST Gas Piping Arc-resistant Protective Jacket is fully tested* [* No product is immune from lightning damage.] Utility Issues with CSST Gas Piping What About Legacy Homes? Utility Issues with CSST Gas Piping Who is On-Board? AMERICAN PUBLIC GAS ASSOCIATION Utility Issues with CSST Gas Piping Customer Awareness Programs www.CSSTSafety.com Questions and Answers? Bob Torbin Director of Codes and Standards [email protected] (413) 388-2390