FABRIMEX POWER SUPPLIES CH-8608 Bubikon/Switzerland POWER SUPPLIES Certified Management-System ISO 9001 Reg. Nr. 12666 Vehicle DC/DC UPS VUPS 75 Watt Series DC/DC UPS module with input / output to case isolation of 1500 VDC • Temperature controlled battery charging • Input polarity protection • Internal battery short circuit protected by fuse • Shock and vibration resistant • PC shutdown signal • Battery low signal • RS232 interface DC/DC UPS Modul mit 1500 VDC Eingangs- / Ausgangsisolation zum Gehäuse • Temperaturgesteuert Batterieladung • Polaritätsschutz (Eingang) • Interne Batterie durch Sicherung kurzschlussgesichert • Stossund Vibrationssicher • PC Abschaltsignal • Battery-low Signal • RS232 Schnittstelle Product range Typenübersicht PART NUMBER VUPS-1375-EV9-C Sommaire des types OUTPUT INPUT VOLTAGE Nom. Voltage Range Current Capacity Nominal 12 VDC 9 - 14.2 VDC 6A 8 Ah 13.2V -1- 300 100 / 9.2006 Nomenclature Nomenklatur Nomenclature VUPS - 13 75 - EV9 - C Product Series Modificationindex Nominal Output Voltage Output Power in Watts Battery Type ! INSTALLATION ONLY BY SKILLED LABOUR ! ONLY TO BE USED IN COMBINATION WITH A FABRIMEX VEHICLE CONVERTER VCUxx-1375-A1P1-H2.C Specifications Spezifikationen Spécifications All values refer to an ambient temperature of 25°C and nominal rated values where nothing else is specified INPUT SPECIFICATIONS Characteristics U in Iin Conditions min Input Voltage Temperature Conrolled by VCU 13.1 Reverse polarity protection Blocked (Diode) typ max unit 14 14.3 Vdc 6 A yes Maximum input current 0 OUTPUT SPECIFICATIONS Characteristics Uout Output voltage charging mode Output voltage discharging mode Conditions min Input voltage present @ 20°C No input voltage present typ max 13.7 9 11 unit Vdc 14.2 Vdc 6 A Uout depending on state of charge Iout Output current -2- 300 100 / 9.2006 Specifications Spezifikationen Spécifications OUTPUT SPECIFICATIONS, Continued Characteristics Conditions min typ max unit Discharge characteristic Discharge Characteristic Example 1: Output Voltage 14 If the battery is discharged for 1h with 6A, the output voltage drops to 10V. If the battery is discharged for 20min with 2A, the discharge depth drops to 50%. Battery Voltage [V] Example 2: Discharge Depth 13 12 11 10 6A 4.8A 2A 1.4A 0.8A 9 8 0.01 0.1 1 10 100 Time [h] Operation time of new battery (30% discharge) 0°C, 6A see discharge characteristic above Operation time of new battery (100% discharge) 20 min 60 min Short circuit protection Fused Yes Curren Limit Current limit is in VCU unit none CHARGER SPECIFICATIONS Characteristics Battery package (sealed lead-acid batteries) min typ max unit 12V, 8Ah @ 10h / 20°C (Eurpower EV 9-12) Charging current Charge Current vs. Load Current 2.5 2 Charge Current [A] ICharge Conditions 1.5 1 0.5 0 0 3.5 5.7 Load Current [A] -3- 300 100 / 9.2006 Specifications Spezifikationen Spécifications CHARGER SPECIFICATIONS Characteristics Conditions min typ max unit Maintenance charge Ambient temperature sensitive UBatt Charging voltage @ 20°C UBatt Maximum charging voltage @ 0°C UBatt Minimum charging voltage @ 50°C Typical charge time 30% discharge, 0A to 3.5A load, 20°C 2 h Typical charge time 30% discharge, 3.6A to 5A load, 20°C 5 h UBatt Deep discharge protection Ubatt < 9V, batterie will be disconnected UBatt Battery short circuit detection *) *) Automatic 13.5 Vdc 14.1 13.1 Battery cycles at 30% battery discharge depth, see also "Life Cycle" page 5 Reverse battery protection Fused Vdc Vdc 9 Vdc <8 Vdc 1'000 cycles Yes If battery short circuit detection has been activated, remove battery and charge seperately. ENVIRONMENTAL SPECIFICATIONS Characteristics Ta Conditions min Battery ambient temperature range Limited by battery Vibration (sinusoidal) IEC 68-2-30, test FC; prEN 1789 Frequency 5-500 HZ Swep 1 Oct/min Cycles 4 scans per 3 axes -20 2 typ max unit 50 °C g Applies only to UPS electronic, no guarantee for battery is taken Shock (half sinus) IEC 68-2-27, test EA Number of pulses 18 in 6 directions Pulse duration 6 ms 30 g 15 g Applies only to UPS electronic, no guarantee for battery is taken Bump (half sinus) IEC 68-2-29, test EB; prEN 1789 Frequncy 1-3Hr Number of pulses 3000 in 6 directions Pulse duration 6ms Applies only to UPS electronic, no guarantee for battery is taken GENERAL SPECIFICATION Characteristics Uiso Isolation voltage Conditions min input/case; output/case typ max 1'500 unit VDC (no input/output isolation) Dimensions LxWxH Terminals 4-pole female mm ca. 190x75x131 MSTB 2,5 HC/4-GF-5.08 4-pole male MSTB 2,5 HC/4-STF-5.08 2-pole female MSTB 2,5 HC/2-GF-5.08 2-pole male MSTB 2,5 HC/2-STF-5.08 Wheigt 3.5 kg SIGNAL SPECIFICATION Characteristics PC shutdown signa standard Conditions min Standard typ unit RS232 Input power fail signal Positive Battery low / shutdown signal Positive Internal battery short circuit max 'On' when short circuit -4- Red LED signal 300 100 / 9.2006 Specifications Spezifikationen Spécifications LIFE CYCLE AND MAINTENANCE Characteristics Conditions min Life Cycle Time typ max unit Cycles vs. Descharge Deep 100 Example: 90 80 Discharge Deep [%] Discharge of 40% corresponds 900 charging cycles 70 60 50 40 30 20 10 0 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 Cycles tsb Stand-by Time Lifetime vs discharge depth ed n i ef D e B To Maintenance Recommendation 1: If the unit is not used for a longer period of time, the fuse shall be removed. Maintenance Recommendation 2: Owing to the automatic discharge, it is recommended to recharge the VUPS every 6 months. Wiring Shematic VCU - VUPS +Vi +Vo Vi -Vo Gi Vi VUPS VCUxx-1375-A1P1-H2.C -Vi Vo Adj Vadj Gadj Gadj RS232 Load Go Gi RS232 Standart RS232 Extension Cable -5- 300 100 / 9.2006 Case Gehäuse Boîtier 131 45 55 View from bottom; Normal tolerance 1/10 ±0.5 mm, 1/100 ±0.25 mm; Pin tolerance 0.5 mm diameter 177 15 45 15 190 177 Cleaning Waschen Lavage The modules are cleanable with the today's known and in the electronics industry usually used products. Due to the different cleaning processes and new available products, we highly recommend to do a compatibility test when using the converters the first time. Die Module sind waschbar mit den heute bekannten und in der Elektronikindustrie üblichen Reinigungsmitteln. Bedingt durch die verschiedenen Reinigungsprozesse und neu auf den Markt kommende Mittel, raten wir dringend beim Ersteinsatz der Konverter eine Verträglichkeitsprüfung vorzunehmen. Les modules sont lavables avec les solvants couramment utilisés dans l'industrie électronique. Dû aux differents processus de lavage et aux nouveaux détergents disponibles sur le marché, il est strictement recommandé de faire un test de compatibilité avant la première utilisation. Notice: All statements, technical information, and recommendations related to FABRIMEX's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utlizing the product, the user should determine the suitability of the product for its intended use. POWER SUPPLIES Germany: CAC FABRIMEX GmbH • DE-89543 Gerstetten Tel: 07323/ 950-0 • Fax: 07323/ 95050 Switzerland: FABRIMEX AG • Techcenterstrasse 2 CH-8608 Bubikon Tel: +41-55-253 31 90 • Fax: +41-55-253 31 91 Internet: www.fabrimex.com -6- 300 100 / 9.2006