Energy Storage, Conversion & Electrical Power Management Merlin Data-Cell Preliminary data Unit available quarter one 2010 RS-232 Battery Capacity Monitoring Module The fit and forget method of constantly measur- APPLICATIONS ing voltage and remaining capacity in up to four Data-Cell has applications any- separate battery banks for computer based where there is a reliance on battery monitoring power and computers are present. For example, in UPS for emergency Once installed, Data-Cell will learn the capacity access equipment, medical equip- remaining in your batteries and never run out of syncronisation ment, for rail signaling, electric vehicles, military, solar & telecoms Connect to any windows based PC to set the battery backup. The applications unit up, view Data-Cell information on ‘virtual are almost endless battery monitor’ displays and perform datalogging EASY TO INSTALL RS-232 data can be utilised by software engi- The unit simply requires a fused neers to design graphical displays for any third positive connection to each battery party computer software bank it is monitoring and a common negative. The unit is supplied with windows based software for monitoring, data-logging and setup Merlin Data-Cell is a ground breaking step forward for capacity information (for up to four separate battery anyone reliant on battery power for a professional appli- banks) using only a positive connection to each battery cation, where computer based monitoring is possible. bank and a common ground. Via its own simple to use windows software, battery reserves can be viewed on EASY TO CONFIGURE Data-Cell is extremely easy to configure via the software provided. You simply choose your battery types and set your activation and deactivation levels for voltage and capacity alarms. Interpreting Data- Rather than simply displaying voltage (which does not ’virtual battery monitor displays’ and alarms can be set for indicate true state of charge) or counting ampere hours both low and high voltage and capacity remaining (%). with a shunt, Data-Cell not only accurately measures remaining battery capacity, but does this reliably through In addition to this, Data-Cell software allows you to per- the batteries entire lifespan, without ever requiring man- form data-logging, recording historical information while ual re-syncronisation. viewing moving ‘heart monitor’ style graphs. Designed by Merlin’s own in house R&D team, the unit Setting the unit up is very straightforward, you simply uses a range of advanced algorithms for different chemis- select the battery type you wish to monitor. Data-Cell then tries to track capacity in a way never seen or experienced learns ‘battery capacity’ for itself. If who want to use Data- before. Data-Cell will provide continuous voltage and Cell information within third-party software platforms, Cell information in third party software, is also very straightforward. Merlin are happy to supply information to allow easy interpretation of the units RS232 output. Energy Storage, Conversion & Electrical Power Management Installation & Battery Types Data-Cell will operate on both 12V and 24V battery systems. Simply choose the part number required for the number of battery banks you want to monitor. Multiple battery bank Data-Cell’s are capable of monitoring multiple battery types. Battery types: OTHER PRODUCTS & SERVICES AVAILABLE Split Charging Systems Batteries • • • • • Deep cycle, wet cell, antimony lead acid Gel cell, lead acid VRLA (valve regulated lead acid) AGM, absorbed glass matt (VRLA) Hybrid—calcium / antimony lead acid Carbon fibre lead acid Battery Management Systems Power Inverters Smart Battery Chargers Combi Charger / Inverters AC Monitors Alternators & Regulators DC & AC Distribution Components Specialist Wire & Cable Multiplex Power Systems Portable Power Packs Alternative Energies Full CAD Design Sub-Assembly & Loom Manufacture Panel Building Technical Specifications DATA-CELL SPECIFICATION MERLIN PART NUMBER SUPPLY VOLTAGE RANGE SUPPLY CURRENT 5mA DISPLAY ON <15mA STATE OF CHARGE (CHARGE) STATE OF CHARGE (DISCHARGE) Merlin Equipment Ltd Unit 4, Cabot Business Village, Holyrood Close, Cabot Lane, Poole, Dorset, BH17 7BA, United Kingdom T +44 (0)1202 697979 F +44 (0)1202 691919 E [email protected] W www.merlinequipment.com 8-40V DC SLEEP MODE OPERATING TEMPERATURE RANGE ACCURACY 04-3002 (1 Batt Bank), 04-3003 (2 Batt Banks) 04-3004 (3 Batt Banks), 04-3005 (4 Batt Banks) VOLTAGE DIMENSIONS WEIGHT STANDARDS COMPLIANCE -40 TO +85C +/- 10% +/- 5% +/- 0.5% TBA 0.2 Kg CE, ISO7637-2