* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download LP-FXZAN13-0 Zone Controller and Actuator
Rotary encoder wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Control theory wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Control system wikipedia , lookup
Two-port network wikipedia , lookup
Light switch wikipedia , lookup
Mains electricity wikipedia , lookup
Switched-mode power supply wikipedia , lookup
National Electrical Code wikipedia , lookup
Opto-isolator wikipedia , lookup
Installation Instructions Issue Date LP-FXZAN13-0 March 16, 2007 LP-FXZAN13-0 Zone Controller and Actuator Assembly Application The LP-FXZAN13-0 Zone Controller and Actuator Assembly (hereafter referred to as the FXZAN) is a digital controller and actuator assembly designed specifically for use with the Facility Explorer Commercial Zoning Package. 2. Position the actuator on the damper shaft so that the damper shaft protrudes through the actuator coupler. 3. Verify that the actuator is in the desired mounting position, parallel to the mounting surface. 4. Hold the actuator in place on the damper shaft, and insert a No. 10 self-drilling sheet metal screw through the shoulder washer. 5. Place an 8 mm (5/16 in.) socket on the screw and use a drill and extension to drill the screw into the mounting surface. Drive the screw until it is tight against the washer. Do not overtighten the mounting screw; it may strip the threads. 6. Make a note of the rotation range and direction, either Clockwise (CW) or Counterclockwise (CCW), required to open the damper. See Figure 2. Installation Prepare the FXZAN for mounting using the following procedure: 1. Check that you have the essential equipment and tools and ensure the installation site meets environmental requirements. 2. Make sure the mounting location has adequate clearance for future servicing. Mounting Location Considerations Consider the following when positioning and orienting the FXZAN: • Mount the FXZAN on a vertical, flat surface where it functions best, such as the side of the zone damper. • Verify wiring terminals are accessible. • Ensure that no extra mounting brackets, linkage, or couplers are required for standard mounting. • Locate the FXZAN so that it has adequate clearance for future servicing and is protected from moisture and corrosive fumes. To mount the FXZAN: 1. Check that the damper blade is accessible or its position is permanently marked on the end of the damper shaft as illustrated in Figure 1. 7. Figure 2: Damper Rotation Grasp the damper shaft firmly with pliers and either manually close the damper (90° boxes) or manually open the damper (45 or 60° boxes). Figure 1: Damper Position Icons © 2007 Johnson Controls, Inc. Part No. 24-10173-5, Rev. C 1 www.johnsoncontrols.com 8. Press and hold the gear release lever, and rotate the actuator coupler until it contacts the mechanical end stop at either the fully closed (90° boxes) or fully open (45 or 60° boxes) position. Read these precautions before touching the terminals or wiring the FXZAN and its accessories: • Make all wiring connections in accordance with the National Electrical Code (NEC) and state and local regulations. For transformer primaries above 150 VAC, the secondary must be earth-grounded at the transformer to meet NEC. Since the power supply for the FXZAN is not isolated, earth ground can be introduced into the system. Avoid multiple earth ground paths and use isolation transformers if necessary. • Locate the equipment and route the wiring so that twisted pair signal wiring is separated from power wiring by at least 150 mm (6 in.). • Make all wiring connections to the FXZAN using only copper conductors. To establish tight, reliable electrical connections, use the correct wire sizes for the terminals. Avoid very thin solid wires, such as 26 AWG or less than 0.6 mm, which tend to break. • Use a daisy-chained configuration for the N2 Bus. The use of Y or T connections without a repeater installed as the T-tap may cause a loss of communications. Make sure there is at least one End-of-Line termination on the N2 Bus (the FX16 or FX40 Series controller). • Do not run N2 Bus, Analog Input (AI), Binary Input (BI), Analog Output (AO), or Binary Output (BO) wiring in the same conduit as line voltage wiring (above 30 VAC), or with wiring that switches power to highly inductive loads such as contactors, coils, motors, or generators. • Run AI, AO, and BI wiring in the same bundle or conduit where convenient. If the BO wiring is not wired through other switches or contacts, such as actuator end-of-travel switches, bundle it with the other Input/Output (I/O) wiring where convenient. If the damper for the 90° boxes closes counterclockwise, then rotate the coupler to the counterclockwise mechanical limit. If the damper for the 90° boxes closes clockwise, then rotate the coupler to the clockwise mechanical limit. The open end stop is automatically set for 90° boxes. Hard stops must be provided for 45° and 60° boxes at both fully closed and fully open damper positions. By installing the FXZAN at the fully open position, the FXZAN provides the open stop for 45° and 60° boxes. 9. Using a crescent wrench, an 8 mm (5/16 in.) square wrench, or a 10 mm (3/8 in.), 12-point socket wrench, tighten the actuator set screw to the damper shaft to 17 to 21 N⋅m (150 to 185 lb in. [14 lb⋅ft]). 10. Push the gear release lever down and turn the actuator coupler by hand to ensure that the damper can rotate from full closed to full open without binding. Note: For proper operation, the actuator’s mechanical stop should engage when the damper is fully open. The damper seal should engage when the damper is fully closed. Wiring ! WARNING: Risk of Electric Shock. Disconnect each of multiple power supplies before making electrical connections. More than one disconnect may be required to completely de-energize equipment. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. IMPORTANT: Binary outputs DO1 and DO2 are connected to the M9104-AGA-3S actuator. If disconnected, do not allow the outputs to short when they are energized. Use the following general wiring considerations: • The FXZAN includes isolated N2 and isolated binary outputs DO3 – DO6. • The 24 VAC power input is not internally transformer-isolated by the FXZAN. • The FXZAN is not meant for high voltage. To wire the FXZAN: 1. Terminate wiring per the engineering drawings. 2. Install the N2 Bus to the FX16 Master Controller in a daisy chain only (see Figure 3.) 3. Connect power to the FXZAN. 4. Commission and balance the FXZAN. 2 LP-FXZAN13-0 Zone Controller and Actuator Assembly Installation Instructions Figure 3: FXZAN Wiring Diagram LP-FXZAN13-0 Zone Controller and Actuator Assembly Installation Instructions 3 Setup and Adjustments Table 1: FXZAN Wiring List Name Description Connection AI1 A99 temperature input Zone temperature (room sensor terminal 2) AI2 A99 temperature input Warm/cool adjustment (room sensor terminal 1) AI3 A99 temperature input Unused AI4 A99 temperature input Unused AICOM Analog input commons Room sensor terminal 3 DI1 Voltage-free contact Temporary occupancy (room sensor terminal 5) DI2 Voltage-free contact Unused DI3 Voltage-free contact Unused DI4 Voltage-free contact Unused DI5 Voltage-free contact Unused DICOM Digital input commons Room sensor terminal 6 AO 0 – 10 V, 5 mA maximum Auxiliary heat valve AOCOM Analog output common Auxiliary heat valve common DO1 Triac output Connected to CW terminal of the M9104 DO2 Triac output Connected to CCW terminal of the M9104 Setting N2 Addresses To set up the FXZAN, you must set the N2 address. The factory default address is 255. Figure 4: FXZAN Front Panel Display To set the N2 address: 1. Supply power to the unit. Once powered, the FXZAN front panel displays the current damper position (in percentage open). 2. Press the Down button to cycle through the available parameters until Add appears. 3. When the FXZAN Front Panel displays Add, press the Enter button. 4. Using the Up and Down buttons, select the N2 address for the FXZAN. See Table 2 for proper addresses. 5. Press the Enter button to confirm your N2 address selection and accept the change. 6. Cycle power to the FXZAN to set the N2 address. Table 2: Zone Addresses Zone N2 Address Zone N2 Address 1 3 9 11 2 4 10 12 5 11 13 DO3 SPST Relay Auxiliary heat stage 1 or parallel fan 3 4 6 12 14 DO4 SPST Relay Auxiliary heat stage 2 5 7 13 15 6 8 14 16 7 9 15 17 8 10 DO5 SPST Relay Unused DOM 3, 4, 5 Digital Output Commons Auxiliary heat commons DO6 SPST Relay Unused DO6COM Digital Output Common Unused 4 LP-FXZAN13-0 Zone Controller and Actuator Assembly Installation Instructions Temporarily Overriding the Current Position of the Damper Motor To temporarily override the current position of the damper motor, do the following: 1. 2. Press the Down button to cycle through available parameters until ord appears. Press the Enter button. Press the Down button to cycle through the display and choose one of the following: • AUT – Auto. The damper follows the commanded position. • oPE - Open. The damper drive is fully open. • CLo - Closed. The damper drive is fully closed. • Table 3: FXZAN Front Panel Display – Available Parameters Parameter Description 0 to 100 Default display. Current damper position appears as 0 to 100% open. Add Current N2 address. 255 is the factory default. rT Current value of the zone temperature sensor SPo Current value of the zone sensor setpoint offset with warmer/cooler adjustment setting ord Override. Used to override the damper position. PoS Commanded damper position. Used when ord is set to PoS PoS - Position. The damper drives to position specified by the PoS parameter (0 to 100% open). Table 4: FXZAN Front Panel Display – Light-Emitting Diode (LED) Important Damper position overrides may be lost once the FXZAN comes online with the FX16 Master Controller. Table 2: FXZAN Front Panel Display – Buttons Button Button Image Description Down Cycle through available parameters Up Cycle through available parameters Enter View, change, and confirm value of selected parameter Function Escape LED Status Description 1 Right On Unreliable zone sensor Off Normal zone sensor Repairs and Replacement Table 5: Available Models and Accessories Code Number Description LP-FXZAN13-0 Zone controller and actuator assembly LP-KIT006-005C Zone temperature sensor with push button for temporary occupancy and warm/cool adjustment dial; includes wall mounting base and hardware LP-FXZAN13-0 Zone Controller and Actuator Assembly Installation Instructions 5 Technical Specifications FXZAN Zone Controller and Actuator Assembly (LP-FXZAN13-0) Power Requirements 24 VAC ±15% at 50/60 Hz; 7.3 VA at Maximum Power Supply; Class 2 Supply Voltage 24 VAC (±15%) Power Consumption 7.3 VA Ambient Operating Conditions 0 to 52°C (32 to 125°F) Ambient Storage Conditions -29 to 66°C (-20 to 150°F) Electrical Terminations I/O: 1/4-in. spade lugs with pluggable blocks N2: pluggable block Housing Galvanized sheet metal, IP20 Actuator: Plenum rated, IP40 Dimensions (H x W x D) Actuator Torque 110 x 171.5 x 138.9 mm (4.34 x 6.75 x 5.47 in.) 4 N⋅m (35 lb.in) minimum Shipping Weight 1.27 kg (2.8 lb) Electrical Inputs AI1-4: A99 sensors (-40 to 100°C/-40 to 212°F) Non-isolated - spare inputs must be connected to common DI1-5: Voltage free contacts, non-isolated Electrical Outputs AO: 0 – 10 VDC @ 5 mA max. Non-isolated DO1, 2: 24 VAC Triac 500 mA. Isolated (used to drive the actuator) DO3, 4, 5: SPST relays. 24 VAC @ 500 mA max Isolated from electronics Shared common DO6: SPST relay. 24 VAC @ 500 mA Isolated Standards Compliance M9104-AGA-3S: UL Listed, File 27734, CCN XAPX (United States) XAPX7 (Canada) Plastic housing is plenum rated per CSA C22.2 No. 236/UL 1995 Heating and Cooling Equipment CE Mark, EMC directive 89/336/EEC C-Tick Mark, Australia/NZ Emissions Compliant LP-FXZAN13-022F: CE Directives 73/23/EEC, EN60730; 89/336/EEC, EN50081-1, EN50082-2 UL 873 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls® office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group Global Headquarters 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 6 LP-FXZAN13-0 Zone Controller and Actuator Assembly Installation Instructions Published in U.S.A. and Europe www.johnsoncontrols.com