LUMIDAS-T
TUNNEL LAMPS TECHNICAL MANUAL
LED Lighting Solutions by Fawoo Technology
01. Model Names
& Product Types
02. Specifications
03. Technical Data
04. Installation
05. Cautions & Warranty
1. Model Names
2. Product Types
1.
2.
3.
4.
Product Images
Characteristics & Applications
Specifications
Drawing
1. Luminous Intensity
Distribution and Illumination
2. Distinctive Features
of the Luminous Sources
LUMIDAS-T SERIES
INDEX
01. MODEL NAMES & PRODUCT TYPES
LumiDas-T LED tunnel lamps can replace existing conventional tunnel
lamps. LumiDas-T LED tunnel lamps consume energy much less than the
conventional tunnel lamps. The LED tunnel lamps are slim and very
shock-resistant. A LumiDas-T tunnel lamp is equipped with a built-in
Fawoo converter.
1. Model Names
Series
Watt
Voltage
Sleeve
Color, Coating of Body, Beam Angle
(
TL = Tunnel
Light
55
80
100/280V
=AC100-280V
S = Standard
)
PF = Pure White, Fluorine Coating
2. Product Types
Models
Options
TL55-100/280VS
Waterproof & Dustproof (IP66)
TL80-100/280VS
Built-in Fawoo converter
LUMIDAS-T SERIES
01. Model Names & Product Types
02. SPECIFICATIONS
LumiDas-T LED tunnel lamps can replace existing conventional tunnel
lamps. LumiDas-T LED tunnel lamps consume energy much less than the
conventional tunnel lamps. The LED tunnel lamps are slim and very
shock-resistant. A LumiDas-T tunnel lamp is equipped with a built-in
Fawoo converter.
1. Product Images
TL55-100/280VS
TL80-100/280VS
LUMIDAS-T SERIES
02. Specifications
LUMIDAS-T SERIES
02. Specifications
2. Characteristics & Applications
1) Characteristics
• Uses only LED chips manufactured by major companies with international patents
• Beautiful design and optimum heat dissipation design
• Instant lighting (takes no time to light and restart)
• Durable and shock resistant
• Wide range of input voltage (AC100-280V, 50/60Hz)
• Maintain low temperature due to unique superb heat dissipation system
• Lower power consumption than conventional tunnel lights
• Eco-friendly: No Mercury, no Lead, no Cadmium is included
• Save replacement costs due to long lifetime (30,000~50,000hours)
• Waterproof & dustproof system(IP66)
2) Applications
• Lighting for indoor and outdoor tunnel
• Lighting for train tunnels, road tunnels, underpasses, underground parking places, and etc.
• Effective and safe lighting due to high efficacy of LED light sources and long lifetime anti-corrosive
materials
3. Specifications
Recommended
Power
Model
Input Voltage
Color
Beam
Luminous
Temperature
Angle
Flux
CRI
Frequency
Consumption
Operating
Weight
Ambient
Temperature
TL55-100/280VS
55
W
3451 lm
9.8
kg
70
AC100~280V
50 ~ 60 Hz
Pure White
-20 ~ 35
130 ˚
±3
TL80-100/280VS
80
W
5426 lm
9.9 kg
℃
4. Drawing
TL55-100/280VS, TL80-100/280VS
LUMIDAS-T SERIES
02. Specifications
03. TECHNICAL DATA
LumiDas-T LED tunnel lamps can replace existing conventional tunnel
lamps. LumiDas-T LED tunnel lamps consume energy much less than the
conventional tunnel lamps. The LED tunnel lamps are slim and very
shock-resistant. A LumiDas-T tunnel lamp is equipped with a built-in
Fawoo converter.
1. Luminous Intensity Distribution & Illumination
(1) Luminous Intensity Distribution
1) TL55-100/280VS
2) TL80-100/280VS
4M
기준
4M
기준
Unit (Lux)
Unit (Lux)
LUMIDAS-T SERIES
03. Technical Data
(2) Illumination: RELUX Simulation
1) Simulation #1
Conditions
- Model :
TL55-100/280VS
- IES data :
Test report by Korea Electric Test Institution (KETI)
- Road Width :
12m
- Spacing between Luminaries : 3m
- Pole Height :
5m
- Number of Luminaries :
22
- Arrangement of Luminaries :
Opposite
Tested at angle of 45˚
Test Result
Average Flux
Maximum Flux
Minimum Flux
147 Lux
167 Lux
115 Lux
LUMIDAS-T SERIES
03. Technical Data
2) Simulation #2
Conditions
- Model :
TL80-100/280VS
- IES data :
Test report by Korea Electric Test Institution (KETI)
- Road Width :
12m
- Spacing between Luminaries : 3m
- Pole Height :
5m
- Number of Luminaries :
22
- Arrangement of Luminaries : Opposite
Tested at angle of 45˚
Test Result
Average Flux
Maximum Flux
Minimum Flux
182 Lux
204 Lux
145 Lux
LUMIDAS-T SERIES
03. Technical Data
2 . Distinctive Features of the Luminous Sources
1) LumiDas-T LED lamps consumes dramatically lower energy than conventional metal halide/sodium lamps. Lifetime of LumiDas-T lamp is longer
than conventional lamps due to the nature of LEDs. Also the LED tunnel
lamp has higher Color Rendering Index (CRI) than metal halide/sodium
lamps. (CRI, Metal Halide: 65, Sodium: 28, Mercury: 23, LumiDas-T: 70)
2) While conventional light sources take time to initiate and restart lighting,
LumiDas-T turns light on instantly by turning on a switch.
3) Wavelength of LumiDas-T does not include range of wavelength which
attracts insects.
4) Spectrum Graph
5) Eco-friendly feature: no Mercury and no Natrium is included in the product.
LUMIDAS-T SERIES
03. Technical Data
LUMIDAS-T SERIES
03. Technical Data
6) LED Packaging
7) Beam Angle (Distribution)
LEFT HALF
RIGHT HALF
TOTAL VIEW ANGLE
X
56.7
57.3
114
Y
58.2
54.9
113.1
8) White CIE Bin Spec [Condition: 60mA, Ta = 25℃
℃]
9) Color Rendering Index
Ra : 70 (IF=20mA/chip)
The tolerance of Intensity measurement : ± 10%, The tolerance of VF measurement : ±60.1V
LUMIDAS-T SERIES
03. Technical Data
04. INSTALLATION
LumiDas-T LED tunnel lamps can replace existing conventional tunnel
lamps. LumiDas-T LED tunnel lamps consume energy much less than the
conventional tunnel lamps. The LED tunnel lamps are slim and very
shock-resistant. A LumiDas-T tunnel lamp is equipped with a built-in
Fawoo converter.
Tunnel Lamp: 55W, 80W
** Before installation, power must be disconnected.
1. Connect the lamp body to the fixing bar with bolts securely.
2. Various types of a fixing bar can made and used for the installation places.
You don’t have to use the enclosed one.
3. Connect an assembly lamp to an installation guide bar.
(Set up an installation guide bar separately)
Installation
설치도 Drawing
Fixing Bar
& Bolt
Installation
Guide Bar
Wire
Earthing
접지
배선도Diagram
Earthing
(Green)
AC Input
(White)
LUMIDAS-T SERIES
04. Installation
05. CAUTIONS & WARRANTY
LumiDas-T LED tunnel lamps can replace existing conventional tunnel
lamps. LumiDas-T LED tunnel lamps consume energy much less than the
conventional tunnel lamps. The LED tunnel lamps are slim and very
shock-resistant. A LumiDas-T tunnel lamp is equipped with a built-in
Fawoo converter.
1. Cautions
1) Please read this section carefully before installation for safe use of LumiDas-T.
2) Place for installation must be checked for sturdiness and any defects before
installation.
3) Make sure input power is suitable for LumiDas-T.
4) Take extra care to prevent damage on surface of the lamp by sharp materials
and/or external shocks.
5) Do not expose the lamp to heat.
6) Correct installation of the ground wire (earthing) can prevent unintentional
short circuit or electric leakage.
7) Power must be disconnected when installing, maintaining, or repairing.
8)
Do not use chemical cleanser when cleaning.
9) After installation, check the shape and status of installation thoroughly to
prevent falling.
10) Do not disassemble the lamp without presence of authorized person. No userserviceable pats inside. It may cause fire and/or an electric shock.
11) It is recommended to use the lamp at ambient temperature of -20℃~35℃ to
enjoy normal life of the lamp.
LUMIDAS-T SERIES
05. Cautions & Warranty
2. Warranty
1) Warranty covers;
- Defects discovered while using the lamps under normal and recommended
operating conditions during the warranty period.
- During the warranty period given at the date of purchase, we will repair or
exchange defect parts or products at no cost.
2) Warranty does not cover;
- When defects are discovered after the warranty period expires
- When defects are caused by natural disasters and accidents
- When defects are caused by negligent handling by users
Negligent handling consist of the following but not limited to;
* Any unauthorized disassembly
* Any accidental impact or shock
* Negligent handling, moving and installing
* Installing at any improper place which could not sustain weight of the lamp
* Installing at excessive input voltage out of designated range of input voltage
* Loss of warranty or omission of required information on the warranty
LUMIDAS-T SERIES
06. Cautions & Warranty
Fawoo Technology CO.,LTD
739-8,Ojeong-dong, Ojeong-gu,
Bucheon, Gyeonggi-do,
Republic of Korea (zip) 421-170
Tel: +82-32-670-3000
Fax: +82-32-670-3100
URL: http://www.fawoo.com/light_en/
For purchase and product enquiry
+82-32-670-3231