Download Table Of Contents DISplus

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Fault tolerance wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Buck converter wikipedia , lookup

Control system wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Time-to-digital converter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

Distribution management system wikipedia , lookup

Public address system wikipedia , lookup

Heterodyne wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Test probe wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Rectiverter wikipedia , lookup

Multimeter wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Oscilloscope wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
Table of Contents
DISplus
Subject
Page
DISplus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Purpose of the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Diagnostic Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
DISplus Cables and Leads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Workshop Network Connection. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Establishing a Connection With the Diagnostic Head. . . . . . . . . . . . . 15
DISplus Program Overview
DIS Start Screen with Program Summaries. . . . . . . . . . . . . . . . . . 18
Measurement System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Multimeter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Oscilloscope Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Preset Measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Output Stimulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Workshop Hints
Administration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Initial Print Date: 11/09/00
Revision Date:12/04/00
Diagnosis and Information Systems
Equipment: DISplus
Objectives:
After completing this module you should be able to:
•
Compare and contrast the functions performed by the DISplus.
•
Understand how to establish communication between the Diagnostic Head and the
DISplus.
•
Describe what components and connections establish a workshop LAN.
•
Recognize the measurements and tests possible with the DISplus Measuring Systems.
2
Diagnosis and Information Systems
Purpose of the system
The DISplus is the successor to the original DIS
(Diagnosis and Information System) introduced
in 1994.
The purpose of the DISplus is to provide a
technical up-grade over the previous DIS, and
meet the challenges for the next generation of
BMW group vehicles, e.g. E65.
The functions of the DISplus that are similar to
the previous DIS are:
•
•
•
•
Technical Information System (TIS)
Diagnosis Program
Measurement Techniques
Coding Program
As a further advantage over the DIS, the DISplus has Network capability, along with being
prepared for future information media (Internet browser, AcrobatTM reader etc.).
Specifications
•
•
•
•
•
•
•
•
•
500Mhz Intel PentiumTM III processor
128MB RAM
13.6 GB hard drive
DVD drive
Sound card with 2 speakers
Network card for LAN connection (connected into the Service Department network)
Additional SVGA output for connection to an external monitor
15’’ TFT touch screen monitor
Vehicle communication via a diagnostic head (Radio frequency)
Components no longer supported from the previous DIS are:
•
•
•
Label printer (top drawer)
MoDiC II download station (second drawer)
Infrared printer interface
3
Diagnosis and Information Systems
System Components
Monitor
The DISplus uses a 15’’ TFT (Thin Film Transistor)
monitor. It has a pressure sensitive touch screen
controller to direct the curser movement.
The monitor is attached to the DISplus by a 15’
cable that allows it to be used either on the swivel
stand or remotely, e.g. inside of a vehicle.
ON
OFF
Main Power Switch
The main power switch is located in the upper
right hand side, at the rear of the DISplus.
The main switch is turned on first, before turning
the DISplus on from the front panel. The System
Status LED on the front panel should illuminate
amber when the main power has been turned on
(see lower left illustration).
Circuit breakers are located below the DISplus
computer. If the unit fails to power-up, check the
reset of the circuit breakers before calling for
service.
System Status LED
Circuit Breaker
4
Diagnosis and Information Systems
System Indicators and ON/OFF Button
After the main power switch has been turned
on, the DISplus is powered up by pressing the
ON/OFF button on the front panel.
During power up, LED 2 will illuminate. When
the process is complete, the System Status
LED changes from amber to green.
LED 1
System Status
LED 2
Hard Drive active
LED 3
Fault indicator
ON/OFF button
The fault indicator, LED 3, illuminates amber
when there is a fault with the DISplus.
DVD and 3.5” Floppy Drive
The DVD and Floppy drives are located behind
a door on the right side of the unit.
The Floppy drive is used for the boot-up disk
when loading the Diagnosis Program.
The DVD drive is used to load the Basis and
Program CDs for Diagnosis.
The TIS CD is also loaded in the DVD drive and
remains in the drive for the computer to access
during TIS operation.
RF Access Point
The access point is the transfer device
between the hardwired LAN network and the
radio frequency assisted LAN.
The DISplus is connected to the access point
via a network LAN cable. The access point
then communicates with the Diagnostic Head
using a radio frequency LAN link.
See Workshop Network Connection (pg. 12) for
more details concerning networking.
5
Diagnosis and Information Systems
Diagnostic Head
The DISplus uses a Diagnostic
Head similar to the MoDiC III as
the communication link between
the DISplus and the vehicle
electronics.
The Head receives operating
power when the diagnosis cable is
connected to the vehicle.
Communication between the DISplus and the Head can occur two ways:
• Radio frequency (maximum 30m distance)
• Hard wired to the network or DISplus
Measurement Jacks for signal recording
Hardwire connection for network
communication
TD Cable input (for measurements)
Diagnosis cable input
Temperature warning LED (Red)
Communication LED (amber)
Power supply LED (green)
Signal recorder button
(currently not used)
Serial interface connection
6
Diagnosis and Information Systems
DISplus Cables and Leads
DISplus Cables:
TD Cable
Workshop LAN
Connection
MFK 1
(Plugs into Diagnostic
Head )
BMW DIS
Multi-Function Cables
System input
& Stimulation
Output
System
Input
Only
BMW DIS
MFK 2
Stimlation
Output
Only
DIS
BMW
BMW DIS
Trigger
Clip
BMW DIS
SIEMENS
1000 Amp (inductive)
Probe
Secondary Ignition Test
Lead-Used with Secondary
DISplus Diagnostic
Head and Leads
Ignition adapter Kit 12 7 040
(20 pin or 16 pin OBD)
Pressure Sensor
0-25 Bar Reading
Secondary Ignition-Inductive Clip
Used on Vehicles with
Ignition Distributors
25
DC Circuit Breaker
Cable (Stimulation Output)
Temperature
probe
For Individual Cable Capabilities:
Refer to the Diagnosis and Information Systems Chapter
of the Technical Systems Course Material
7
Diagnosis and Information Systems
Diagnostic Cable
20 and 16 pin cables are provided for connection between the vehicle diagnostic socket
and Diagnostic Head.
16 pin OBD II connector
20 pin underhood connector
Test Cables
Various test cables and the main power cable are
connected to the rear of the DISplus through the
conduit channel of the cable arm mast. The
following test cables are stored on the arm.
LAN (Local Area Network) Connection
The LAN connection has the appearance of a
large phone receptacle. It provides the connection for the DISplus to the Ethernet wiring for the
Service Department Network.
TD (RPM input) Cable
The TD input cable is used for specific Test Modules that require a hard wired RPM input
for measurement functions.
TD cable connected
to Diagnostic Head
8
Diagnosis and Information Systems
Multi-Function Test Cable-MFK #1
(two cable ends)
MFK 1 is used to measure:
• Voltage - up to 50 Volts
• Current - up to 2 Amps
• Resistance
• Diode Testing
• Frequency
• Period
• Duty Cycle
• Pulse Duration
• Oscilloscope Measurements
Multi-Function Test Cable-MFK #2
(Four cable ends)
MFK 2 is used to measure:
• Voltage - up to 500 Volts
• Frequency
• Period
• Duty Cycle
• Pulse Duration
• Oscilloscope Measurements
Both MFK 1 and MFK 2 can be used for signal outputs from the Stimulate Output function
of the Multimeter. On MFK 2, the two large cable ends are for input only (measuring) and
the two small ends are for the Stimulate Output function. MFK 1’s leads are for both
measuring and stimulation.
Both large positive cable ends of MFK 1 and 2
include a button used to hold the measured
value on the display screen.
Freeze Button
9
Diagnosis and Information Systems
Trigger Clip (inductive)
The trigger clip is used when testing ignition or
fuel injection systems to establish engine firing
order.
Additional Test Cables
There are additional test cables connected to the rear of the DISplus on the measurement
system board. The ends of the cables are color-coded for easy identification.
1. 1000 Amp probe
5. DC Circuit Breaker
2. 50 Amp probe
6. Pressure Sensor 1
3. Secondary Ignition
Clip
7. Pressure Sensor 2
8. Future Use
4. Temperature Sensor
1
2
10
Diagnosis and Information Systems
3
4
5
6
7
8
Secondary Ignition Test Cables
The inductive clip (1) is used when checking Secondary Ignition on vehicles that use a
Distributor. It is clipped to the vehicle’s distributor wire. The Flat lead (2) is used in
conjunction with the secondary ignition adapter test kit (#12 7 040) when checking vehicles
that have a Static Ignition system.
1
2
1000 Amp Probe
The 1000 Amp probe measures AC and DC current
from 0 to 1000 Amps. It is a self calibrating,
inductive pick-up.
Temperature Sensor
The long temperature probe measures the
temperature of liquids and gasses. The
measurement range is from -20oC to 200oC.
Pressure Sensor
The Pressure Sensor measures from 0 to 25 bar.
There are two pressure inputs to the measuring unit
that permit two different pressures to be measured
simultaneously if two Sensors are used.
11
Diagnosis and Information Systems
DC Circuit Breaker Cable
The DC circuit breaker is used in the Stimulate
Output function to provide a DC power switch
with circuit protection. It is used for testing circuits and components.
Workshop Network Connection
The DISplus has the ability to be integrated into an existing workshop computer network.
Networking allows the DISplus to be connected to the same server as the DCS 2000
system.
Having all of the BMW centers diagnosis equipment on a network, provides BMW with a
method of immediate retrieval of data from vehicle systems that are being diagnosed in the
workshop.
The benefits are, to provide BMW with a better, more complete and in-depth understanding of diagnostic problems and the conditions of diagnosable systems. Also, this information will be used by the Hotline and by Service Engineering to support BMW centers, as
well as for product improvement and development.
In addition to reporting, the DISplus will add a web browser feature. This will enable
technicians to toggle over to the internet and view information on the technical
website.
The Workshop Network consists of:
• DISplus
• Ethernet drop from the BMW center’s DCS 2000 LAN
• Switched hub
• Ethernet Access point with RF transceiver
• Diagnostic bay(s) wired with 3 Ethernet 10base-T connections
• Technical Reference PC (located in the workshop)
• Network Printer: Lexmark M410N post script printer
• I/P address for each device on the Ethernet
12
Diagnosis and Information Systems
Example Workshop Network
Existing
DCS Patch
Panel / Hub
Wall Mounted
RF Transceiver
Wall Mounted
Switched Hub 110V
5’0’‘
Maximum
110V
r
r
ive ea
ce Cl
ns es ht
Tra quir f Sig
Re e o
Lin
Dealer
Services
Frame Relay
Network
Optional
Wire
Connection
110V
30A
DIS
BMW DIS
BMW
110V
110V
Diagnostic Head
13
Diagnosis and Information Systems
Limited
Internet
Access
BM
W
DIS
DIS PLUS
Workshop
PC
Printer
Network Terms Defined
Ethernet
Originally developed by XeroxTM, Ethernet is the most widely used LAN technology. An
Ethernet LAN typically uses coaxial cable or twisted pair wiring. The most common
Ethernet systems are called 10base -T and provide transmission speeds up to 10Mbps.
Internet Protocol (I/P) Address
An Internet Protocol address is a binary number that identifies each sender or receiver of
information that is sent across the internet or LAN. The I/P address is usually expressed
as four decimal numbers, each representing eight bits, separated by periods i.e.
192.168.68.20. The numbers and their sequence provide information to the Network
about which specific device or Host is sending or receiving a message.
Local Area Network (LAN)
A local area network is a group of computers and devices that share a common communications line and may share the resources of a single server within a small geographic area
i.e. within a Dealership. Shared programs can be kept on the LAN server and be accessed
by individuals on the LAN. Also, for example, users can order printing from one centrally
located printer attached to the LAN.
10base-T
Most Ethernet wiring uses ordinary twisted pair phone line to transfer data within a LAN.
The designation, 10base-T is an Institute of Electrical and Electronics Engineers shorthand.
“10” refers to the transmission speed of 10Mbps (megabits per second). Base means that
only Ethernet signals are carried on the line. “T” represents twisted pair. There are other
media used to transfer Ethernet signals that can use coaxial cable or fiber optical cable.
14
Diagnosis and Information Systems
Establishing a Connection With the Diagnostic Head
•
Attach the diagnostic cable to the
head. The cable will only fit in the correct
socket.
Note:
Use the correct cable according to the type of
diagnosis socket that the vehicle has (16 pin OBD
II or BMW 20 pin under the hood).
•
Connect the diagnostic cable to the
vehicle.
•
Turn on the ignition.
•
As a test, all three LEDs will illuminate.
The green LED should stay illuminated to
indicate that the head is receiving
operating power.
•
The amber LED will flash until a
connection to the DISplus can be
established.
•
As soon as the LAN connection with the DISplus is established, the flashing amber LED
will change to a steady light.
•
Connection to the Diagnostic Head of the DISplus can be confirmed and created from
the “Connection Setup” screen of the Administration page.
15
Diagnosis and Information Systems
•
If Radio-LAN communication with the
Diagnostic Head is not possible, a hardwire
cable connection may be made.
DK LAN Cable
•
Connect the DK LAN cable as shown in the
illustration (orange connector).
•
On the DISplus, disconnect the SE LAN
cable (the one connecting the DISplus to the
network). Connect the other end of the DK
LAN cable (that looks like a phone
connector) to the DISplus LAN receptacle.
•
Restart the Head by briefly disconnecting and connecting it to the vehicle to initialize
communication.
Connection Setup (Administration)
When a Diagnostic Head is first introduced to the DISplus or a connection has been lost,
the LAN link may be established using the Connection Setup screen from the
Administration menu. To enter the Administration page, select the “Administration” button
from the main start screen.
Print
Change
End
Services
Help
BMW Administration
TIS
DIS
Update
Update
Update
Installation
Installation
Paper format
Data update
Feedback
statistics
Network
Configuration
Password
Date
Time
Connection
setup
KDS
Self-test
Diskcopy
Calibrating
touchshield
Country
code
Language
Admin.
CD drive allocation
CD drive 1
TIS V3.00.09/2000 - (1/1): 01 57 9 788 177607 US Programs
Activate
CD
Deactivate
CD
Change
CD
Administration Menu
16
Diagnosis and Information Systems
•
Once inside the connection setup
page there will be a box on the left
side called “Free diagnostic
heads”
•
Any Heads that are powered up
and not currently assigned to a
DISplus will be found and listed
in the box. Each head has its own
I/P address for identification to the
DISplus.
•
With the correct Diagnostic Head identified, press the “Connecting” button to establish
the connection.
•
Once the radio LAN link is established, the DISplus will only be able to communicate
with that head. If the use of another head is desired, press the “Quit Connecting”
button from the same page. This breaks the link. Repeat the process for selecting and
connecting as previously described.
Checking the Operation LED Indicators of the Access Point
If communication between the Diagnostic Head and the DISplus is faulty, the LEDs on the
access point may help to determine where the problem is. The indicators operate as
follows:
1
2
3
4
5
6
1.
Status LED: During normal operation the
LED flashes once per second.
2.
Serial LED: Flashes during activity at the
serial interface.
3.
Cable LAN connected LED: “ON”
indicates a valid Ethernet LAN
connection.
4.
Cable LAN active LED: Flashes when
data is being transmitted via the LAN.
5.
Radio LAN connected LED: Lights up
when there is an established connection
between the Diagnostic Head and the
access point
6.
Radio LAN active: During connection
setup and when data is being transmitted
by the Diagnostic head, this LED flickers.
17
Diagnosis and Information Systems
DISplus Program Overview
DIS Start Screen
The first steps to troubleshooting and diagnosis using the DISplus begin at the DIS start
screen.
1
Print
2
3
End
Change
4
5
Help
Services
BMW Diagnosis and Information System
TIS
Diagnosis
6
b
DIS
Measuring
System
Coding
Program
7
Administration
8
DISplus
SIEMENS
1. Print Button
5.
Help Button
2. Change Button
6.
Program Selection Buttons
3. End Button
7.
Administration Menu Button
4. Services Button
8.
Navigation Buttons (Forward and Backward)
18
Diagnosis and Information Systems
Function Buttons (pull down menus)
The Print button allows the user to pull down a menu of print options.
Print
•
Shield prints the entire screen as it is being displayed.
Shield
•
Diagnosis report prints the diagnosis report at any time while it is
being compiled by the diagnosis program.
Diagnosis
report
Feedback prints the report entered using the technician feedback
Feedback
report entry screen.
•
•
Label permits printing a test code or vehicle coding label. The
Label
correct adhesive labels or paper must be used in the network
printer. The label printer in the top drawer of the DISplus is no longer
used.
Documents
•
Documents prints the entire reference document (i.e. ETM, Pin
Assignment, etc).
•
Printer reset clears the printer spool of unprinted documents. This
Test code
helps to speed up the print process by deleting unwanted
documents.
•
Test code prints the stored test code on a full sheet of paper.
•
Stored diagnosis report prints any diagnosis reports that have
been stored but not printed. Once printed, the reports are deleted
from memory.
Printer reset
Stored
diagnosis rep
Note: Most of the print menu items do not function until data has been stored during the
diagnosis process.
Change
Change allows the user to switch to other programs installed in the
DISplus without returning to the DIS start screen.
TIS
Some programs cannot be entered until the task in the current program
is finished (i.e. coding completed before returning to diagnosis).
Diagnosis
Measuring
system
Coding/
Program.
19
Diagnosis and Information Systems
The End function offers the user several options for stopping a current End
running program.
•
Break
Break allows the program to be paused or interrupted without
losing any information or stored data about the currently running test
module. The data may be stored on a floppy disc or the hard drive
and can be recalled by selecting the Job button from the Diagnosis Cancel
start menu.
•
Cancel terminates the running program and returns to the currently
running programs start screen i.e. TIS or Diagnosis.
•
Quit terminates the current running program and returns to the DIS start screen.
Quit
Services
The Services button offers administration functions as follows:
Version
•
Version displays the current operating software.
•
The feedback function allows the user to report back on problems
concerning the diagnosis program. An electronic keyboard on the
screen is used to type in what the problem is. This information can
be printed out and sent to BMW.
•
News presents a summary of new features or functions available on
the installed software version.
•
Setting up a connection is a shortcut to the administration
feature used to connect and disconnect communication with the
radio frequency Diagnosis Head.
Feedback
News
Setting up a
connection
The Help function is available in all screens and provides the user with help
information on the currently running program or function.
Help
Navigation Buttons: These buttons serve different functions in the
various programs. However, they generally allow the user to page forward
or backward in the currently running program.
20
Diagnosis and Information Systems
DISplus Programs
TIS
Pressing the TIS button from the DIS Start
Screen will launch the TIS application and
allow access to all of the available TIS
functions.
Please refer to the Information Resources chapter
for a review of the TIS program.
Diagnosis
Pressing the Diagnosis button will call up the
diagnosis program. The functions available in
the program are:
•
•
•
•
Expert Mode diagnosis for models prior to
the E38 introduction.
Diagnosis with the E38 diagnostic concept
program.
Diagnosis with the E46 diagnostic concept
program.
ETMs in the Diagnosis Program.
Refer to the module titled E46 Diagnostic Concept for a review of the Diagnosis Program.
Coding
Program
Pressing the Coding Program button will
bring up a menu of different coding
applications. The programs contained are:
• Car Memory
• Key Memory
• ZCS Coding
• Programming (drivetrain modules)
• EWS Alignment
Print
Change
End
Services
BMW Coding/programming SELECTION
1
2
3
4
5
6
CAR MEMORY
KEY MEMORY
ZCS CODING
PROGRAMMING
ALIGNMENT EWS-DME
ALIGNMENT EWS-DDE
Note
Car and Key Memory Programming is discussed in the Service and Maintenance chapter.
21
Diagnosis and Information Systems
Measurement Pressing the Measurement system button from the DIS start screen
will call up the Multimeter function.
system
Print
Change
End
Services
Help
BMW Test system Multimeter
Freeze image
8.15 V DC
Minimum
Maximum
10
Measurement
Function
Measurement
Connection
Measurement
Kind
Measurement
Range
0
10
Voltage
V
Resistance
Ohm
Temperature
Current
2A
Current
50A
Current
1000A
MFC 1
MFC 2
Current probe
=
o
System voltage
Rotation speed
C
-|>|-
Diode test
Pressure
bar
Pressure
Sensor
Temperature
Sensor
2nd
measurement
Effective value
automatic
Multimeter
Stimulate
± 500 mV
Counter
Oscilloscope
setting
Stimulators
Preset
measurements
The following programs are available through the multimeter function buttons along the
bottom edge of the screen:
Multimeter
Counter
Oscilloscope
setting
Stimulators
Preset
measurements
For
measurement
of voltage,
amperage,
resistance,
temperature,
pressure,
and diode
testing.
For
measurement
of frequency,
period and
duty cycle.
Digital dual
trace scope
for measuring
wave forms.
Uses the
DISplus
multimeter leads
as a signal
source for DC V
AC voltage,
pulsed signal
generation,
resistance,
and a power
switch.
Pre-arranged
tests that are
used to test the
most commonly
monitored
vehicle signals.
22
Diagnosis and Information Systems
Multimeter
All of the multimeter functions are displayed in the display area of the
screen. Both numerical and bar-graph test results are shown.
Once a function is selected, only the available test leads for that function remain
highlighted.
FREEZES
THE DISPLAY
WHEN
PRESSED
SELECT FUNCTION
OF MULTIMETER:
1. VOLTS
2. OHMS
3. TEMPERATURE
Print
Change
End
Services
4. CURRENT
(2-1000A)
BMW Test system Multimeter
5. DIODE TEST
6. PRESSURE
(bar)
Help
Freeze image
8.15 V DC
Minimum
Maximum
10
0
Measurement
Function
SELECT LEAD
BEING USED
(function
dependant)
SELECT TYPE OF
MEASUREMENT
DC - Direct Current
AC - Alternating Current
Or Effective Value - True
RMS value
Measurement
Connection
Measurement
Kind
Measurement
Range
10
Voltage
V
Resistance
Ohm
Temperature
Current
2A
Current
50A
Current
1000A
MFC 1
MFC 2
Current probe
=
o
System voltage
Rotation speed
C
-|>|-
Diode test
Pressure
bar
Pressure
Sensor
Temperature
Sensor
2nd
measurement
Multimeter
Stimulate
± 500 mV
Counter
ADDS THE
BATTERY
VOLTAGE AND
ENGINE RPM
TO THE
DISPLAY
DISPLAYS TWO
MEASUREMENTS
SIMULTANEOUSLY
Effective value
automatic
CAPTURES
LOWEST &
HIGHEST
READINGS
Oscilloscope
setting
ACTIVATES
STIMULATION
DEVICE
FOR VIEWING
ON COUNTER
THROUGH
OTHER LEADS.
Preset
measurements
Stimulators
CHOOSE RANGE OF MEASUREMENT
OR SET TO AUTOMATIC
Test Connections:
MFK 1
Multifunction cable 1 (with two leads) is used to test all multimeter
functions not requiring special sensors. MFK 1 is used to measure:
•
•
•
•
MFK 2
Voltage - up to 50 Volts
Current - up to 2 Amps
Resistance
Diode Testing
•
•
•
•
Frequency
Period
Duty Cycle
Pulse Duration
Multifunction cable 2 (with four leads)
MFK 2 is used to measure:
• Voltage - up to 500 Volts
• Frequency
• Period
•
•
Duty Cycle
Pulse Duration
23
Diagnosis and Information Systems
Current probe When selecting the 1000A current measurement function, the current
probe will be the default test connection. The current probe is self
calibrating.
Pressure
sensor
When selecting the pressure measurement function, the pressure sensor
will be the default test connection. The reading will begin at
approximately 1 Bar (the reading cannot be zeroed).
Temperature
sensor
When selecting the temperature measurement function, the temperature
sensor will be the default test connection. The reading is only provided in
degrees Celsius.
Type of measurement: Various measurements require defining the type of signal
measured.
DC: Set to test a direct current signal.
AC: Set to test for an alternating current signal.
Effective value Displays a measured AC wave form as the RMS (root-mean-square)
value. The RMS value is the DC equivalent of the voltage or current
produced by an AC wave form.
Measuring Range: Sets scale range for selected measurement.
automatic
+/- 200mV
Scale will automatically range to the best suitable range.
Arrows are provided for the user to manually set range of measurement.
Special Functions
Hold screen
Minimum/
Maximum
Freezes the display with the current test results. Serves the same
function as the buttons on the large MFK1 and 2 test leads.
The current measured value is constantly monitored. The highest and
lowest measured value since the activation of the function is displayed
below the actual display.
24
Diagnosis and Information Systems
System voltage
Engine speed
2nd
measurement
System voltage and engine speed adds an additional field to the
display that measures system voltage and engine RPM along with the
original measurement. This feature requires that the diagnostic head be
connected.
2nd measurement splits the main display field into two separate displays. This permits two measurements from separate test leads to be
displayed at the same time.
Note: only one of the special functions may be enabled and displayed at a time.
Stimulate allows the user to turn on or off the stimulate output function
while in the multimeter. This is useful when applying an output signal to
a vehicle circuit for testing purposes.
Stimulate
Counter
LENGTH OF TIME THE PULSE IS ACTIVE (ON SEGMENT) IN MILLISECONDS
LENGTH OF TIME FOR ONE COMPLETE CYCLE IN MILLISECONDS
% OF TIME PULSE
IS ACTIVE DURING
FULL CYCLE OF WAVE
NUMBER OF PULSES PER SECOND (Hz)
PULSE
DURATION
FREQUENCY (Hz) =
TOTAL NUMBER OF
CYCLES IN 1 SECOND
Print
Change
End
Services
Help
BMW Test system Counter
Hold screen
50 Hz
PULSE DUTY
FACTOR = %
OF ON TIME
Minimum
Maximum
PERIOD = MS TIME
FOR ONE CYCLE
SELECT WHAT
LEAD
ADJUST THE
MONITORING
RANGE OF
COUNTER
ADJUST THE
POINT ON THE
WAVE AT
WHICH THE
COUNTER
BEGINS TO
"COUNT"
0
Test function
Test connection
Test range
50
Frequency
100
Period
Pulse
Pulse duty
duration
duration
factor
MFC 1
System voltage
Rotation speed
MFC 2
automatic
0.1..1 Hz
5.0 V
Trigger level
Stimulate
Trigger edge
Multimeter
LEADING EDGE
Counter
Oscilloscope
setting
Stimulators
Preset
measurments
FREEZES
THE DISPLAY
WHEN
PRESSED
CAPTURES
LOWEST &
HIGHEST
READINGS
ADDS THE
BATTERY
VOLTAGE AND
ENGINE RPM
TO THE
DISPLAY
ACTIVATES
STIMULATION
DEVICE
FOR VIEWING
ON COUNTER
THROUGH
OTHER LEADS.
FALLING EDGE
SELECT THE STARTING POINT ON THE WAVEFORM
WHERE THE MEASUREMENT BEGINS
The counter function of the DISplus measurement system allows the user to measure time
based signals. The measurements are:
• Frequency
• Period
• Pulse duration
• Pulse duty factor
25
Diagnosis and Information Systems
The desired measurement is set-up from the screen by selecting from the following:
• Measurement function
• Test cable
• Measurement range
• Trigger level (default is set at 5 Volts)
• Trigger slope (determines which portion of the signal will be used as the trigger point)
Oscilloscope Function
The oscilloscope function of the DISplus uses a digital dual trace display screen. There are
two methods for setting up the scope to display a pattern: manual setup or preset
measurements.
The oscilloscope setting screen is used to manually select how the measured signal will be
displayed.
TWO CHANNEL SET UP PANELS (A&B) FOR THE DUAL TRACE OSCILLOSCOPE
CHANNEL "A" IS DISPLAYED IN YELLOW
ON THE SCOPE. THE LEADS AVAILABLE
FOR DISPLAY ARE SELECTED HERE.
Print
CHANNEL "A"
MEASUREMENT
TYPE
CHANNEL "A"
MEASUREMENT
RANGE
SET FREQUENCY
RANGE
THIS ADJUSTMENT SETS
THE SCOPE DISPLAY TO
VIEW A SAMPLE PIECE
OF THE WAVE FORM.
CHANNEL "B" IS DISPLAYED IN GREEN
ON THE SCOPE. THE LEADS AVAILABLE
FOR DISPLAY ARE SELECTED HERE.
Change
End
Services
Help
BMW Test system Oscilloscope setting
Channel A
Test connection
Type of test
Test range
Frequency range
Channel B
MFK 1
MFK 2
MFK 1
Trigger
MFK 2
clip
=
=
±10 V
automatic
200 Hz
± 20 V
automatic
Trigger source
Minimum
Maximum
• LOWER HZ VALUE =
LONGER TIME DISPLAY
(STRETCHED PICTURE
OF WAVE FORM)
• HIGHER HZ VALUE =
SHORTER TIME DISPLAY
(CONDENSED PICTURE
OF WAVEFORM)
KV-Sensor
Channel A
Channel B
Trigger
Terminal 1
Clip
TD-signal
Trigger edge
Multimeter
Counter
Oscilloscope
setting
Stimulators
Preset
measurements
CHANNEL "B"
MEASUREMENT
TYPE
CHANNEL "B"
MEASUREMENT
RANGE
POINT AT WHICH
THE SCOPE STARTS
TO DISPLAY THE
WAVEFORM
TRIGGER EDGE:
SETS THE STARTING
POINT ON THE
WAVEFORM WHERE
THE MEASUREMENT
BEGINS
FALLING EDGE
LEADING EDGE
Once the settings are complete and the test connections are made the oscilloscope graph
may be viewed by selecting the “Oscilloscope display” button.
The oscilloscope signal pattern may be adjusted by manipulating the voltage level and the
trigger level (voltage) from within the display screen. If the displayed pattern is still unreadable or incorrectly setup, the oscilloscope settings can be further adjusted by returning to
the settings screen.
26
Diagnosis and Information Systems
Oscilloscope display screen features
Once the signal pattern is displayed, the pattern may be locked on the screen with the
“Hold screen” button or with the freeze image buttons on the test cable leads.
Holding the image will activate the “Cursor”, “Zoom” and “Memory” features. Holding the
image also allows the signal pattern to be visible when printing the screen.
Cursor 1 and 2
This feature is used to measure the amplitude and time differential of the signal pattern.
Activate the feature by pressing the Cursor 1 button first. A vertical line will appear.
Roughly position the line by touching the desired measurement point on the screen.
Anywhere the cursor line intersects the signal pattern, the amplitude value at that point will
be displayed in a box on the right of the display screen. If both traces of the scope are
being used, (both channel A and B) each value will be shown in its own box. A fine adjustment may be made to the cursor line by using the arrow buttons to the left and right of the
cursor buttons.
The time differential between two points may be measured if cursor 2 is used. Place the
second cursor at the desired measurement point. The time difference between the two
cursors will be displayed in the “Time value” box on the right side of the screen.
WITH FREEZE IMAGE SELECTED,
PRESS "MEMORY". USE THE
ARROW BUTTONS ON THE TOP
TO SCROLL BACK THROUGH
9 PULSES OF THE WAVEFORM.
WITH FREEZE
IMAGE SELCTED,
USE CURSOR
BUTTONS TO
MARK MEASURING
POINTS ON THE
WAVE FORM. USE
YOUR FINGER ON
THE SCREEN TO
SET APPROX
POSITION, THEN
USE ARROWS TO
LOCATE EXACTLY.
TIME SCALE OF
WAVEFORM. THIS
SCALE CHANGES
BASED ON
FREQUENCY
ENTERED
IN THE
OSCILLOSCOPE
SET UP SCREEN
Print
ADJUST WITHIN VOLTAGE LEVEL OF
MONITORED SIGNAL TO KEEP WAVE
FROM "WALKING" ON SCREEN.
Change
End
"FREEZES" WAVEFORM ON SCREEN
FOR MEASUREMENT DISPLAY IN
CONJUNCTION WITH CURSOR
BUTTONS OR ZOOM FUNCTION.
Services
Help
BMW Measuring system Oscilloscope display
Cursor 1
A [V]
Memory
Freeze Image
Cursor 2
8 [V]
V
Channel B
8
16
8
6
12
6
4
8
4
2
4
2
0
0
0
-2
-4
-2
T
r
i
g
g
e
r
l
-8 -4 e
v
-12 -6
e
-16 -8 l
-4
-6
-8
-2.0
ADJUSTS VERTICAL POSITION
OF WAVEFORM ON SCREEN BY
ADJUSTING BASELINE POSITION.
-1.0
-1.5
Multimeter
0.0
-0.5
1.0
0.5
Counter
2.0
1.5
Oscilloscope
setting
Stimulators
ms
Preset
measurments
Zoom
Amplitude
Channel A
Amplitude
Channel B
Time value
Stimulate
DISPLAYS
SECOND
CHANNEL
(ie: MFK 2)
AFTER
PRESSING
FREEZE IMAGE
BUTTON PRESS
ZOOM TO SHOW
DETAIL IN TIME
SCALE OF WAVE
(AMPLITUDE OF
IMAGE DOES
NOT "ZOOM")
AMPLITUDE
VALUE DISPLAY
WINDOWS.
DISPLAYS TIME
VALUE OF MARKED
PORTION OF WAVE.
ALSO CHANGES TO
MEMORY COUNTER.
PRESS TO ACTIVATE
STIMULATION DEVICE
FOR VIEWING ON SCOPE.
27
Diagnosis and Information Systems
Zoom
By selecting the “Zoom” button, a section of the signal pattern may be enlarged to show
greater detail. The desired section of the display is called up by touching the screen at the
desired spot.
Memory
Memory pages are stored every time the Hold Screen is activated. The DISplus stores the
last 10 trigger pulses at the time the screen is held. To recall the memory pages, press the
“Memory” button and use the left arrow button to scroll through the previous 9 pages (page
10 is already displayed). The cursor and zoom features may be used on the stored pages.
Preset Measurements
The preset measurements provide an easy method of testing several commonly measured
signals. To enter the presets: Press the “Preset measurements” button on the bottom of
the screen. A pop up window will provide several signals to choose from. Selecting the
signal and pressing the OK button will automatically configure the oscilloscope to the settings needed to provide the best trace pattern. Many tests also have specialized boxes
with additional readings( i.e RPM, system voltage).
For instructions on which cables to use for the preset test, follow the instructions in the
“Preset measurements” selection of the “Help” menu.
Since the oscilloscope settings are pre-determined, no changes to the oscilloscope are
possible.
Print
Change
End
Services
Help
BMW Measuring system Oscilloscope display
Cursor 1
A [V]
Memory
Freeze Image
Cursor 2
8 [V]
V
Channel B
8
Test Screen
6
Rotation speed sensor
TD signal
ti injection signal
Ignition signal, primary (terminal 1 signal)
Ignition signal, secondary
Diesel NBF signal
Diesel rotation speed sensor
Terminal 4a signal
Oxygen sensor (Lambda) signal
Camshaft sensor signa
4
2
0
-2
-6
-8
-1.0
-1.5
Multimeter
0.0
-0.5
Counter
28
Diagnosis and Information Systems
2.0
1.5
Oscilloscope
setting
-2
-8
-4
6
l
e
v
-12 -6
e
-16 -8 l
1.0
0.5
-4
8
12
4
OK
-2.0
0
T
r
i
4 g
g
2
e
0 r
16
8
Further measurements
Alternator test
Relative Compression
Acceleration enrichment
-4
Signal Tests
• Wire Tests
• Potentiometer Tests
Stimulators
ms
Preset
measurements
Zoom
Amplitude
Channel A
Amplitude
Channel B
Time value
Stimulate
Signal Measurements
• Status Diagnostic Socket
• Status of OBD Socket
• Engine speed sensor signal
• TD signal
• ti injection signal
• Ignition signal, primary (terminal 1
signal)
• Ignition signal, secondary
• Diesel NBF signal
• Diesel Engine speed sensor Signal
• Terminal 4a signal
• Oxygen sensor (Lambda) signal
• Idle actuator signals
• Throttle valve potentiometer signal
• Camshaft sensor signal
Further measurements
• Alternator test
• Absolute compression
• Relative compression
• Pressure distribution
• Smooth running
• Xenon Headlight test up to 8/98
• Xenon Headlight test from 9/98
Output Stimulator
The stimulation function of the multimeter can be used to provide an output signal from the
DISplus to test various components or vehicle wiring. MFK 1 and the small leads of MFK
2 are used to conduct the output signal. After selecting the cable, press the Stimulate button in the right lower corner to activate.
The following signal types may be simulated with this function:
• DC Voltage from 0 to 15 Volts
• AC Voltage from 1Hz to 1KHz and 0 to 15 Volts
• Digital frequency from 1Hz to 5KHZ and 0 to 100% duty cycle
• Resistance from 0 to 10Kohm (MFK 1 only)
• DC voltage using on/off switch
1. DETERMINE
WHAT TYPE
OF OUTPUT
SIGNAL IS
REQUIRED
2. ADJUST THE "AMOUNT" OF THE
OUTPUT STIMULATION SIGNAL
Print
Change
End
Services
Help
BMW Test system Stimulation devices
MFK
5.25
DC Voltage source
0V
1
2
1
2
1
2
15 V
5.25
370
THIS FUNCTION
PROVIDES Approx.
12 VOLT OUTPUT
TO SIMULATE
A BATTERY
SUPPLY
Frequency
PROVIDES AN
ADJUSTABLE
RESISTANCE
VALUE IN
SERIES WITH
MFK 1 Only!
1 Hz
Frequency 1000 Hz
0V
Amplitude
15 V
33.5
2.5
Frequency
1 Hz
Frequency 5000 Hz
0 % Pulse duty factor 100 %
3.54
1
Resistance Stimulation device
WITH CIRCUIT
Power Switch
BREAKER CABLE
CONNECTED
TO REAR OF DIS,
POWER SWITCH
Multimeter
Counter
OPERATES THE
POWER FLOW.
SWITCH GRAPHICALLY DEPICTS ON/OFF STATUS
0.01 KOhm
ON
OFF
10 KOhm
Battery voltage
1
2
Stimulate
Oscilloscope
setting
3. CHOOSE
WHERE THE
OUTPUT
SIGNAL
WILL BE
ACCESSED
(MFK ?)
Stimulators
Preset
measurements
4. STIMULATE
BUTTON
MUST BE
PRESSED
TO ACTIVATE
FUNCTION
29
Diagnosis and Information Systems
Workshop Hints
Administration
The Administration page is used to access various installation, test and house keeping
functions for the TIS, DIS system programs. The Administration menu offers the following
options:
Print
Change
End
Services
Help
BMW Administration
TIS
DIS
Update
Update
Update
Installation
Installation
Paper format
Data update
Feedback
statistics
Network
Configuration
Password
Date
Time
Connection
setup
KDS
Self-test
Diskcopy
Calibrating
touchshield
Country
code
Language
Admin.
CD drive allocation
CD drive 1
TIS V3.00.09/2000 - (1/1): 01 57 9 788 177607 US Programs
Activate
CD
Deactivate
CD
Change
CD
TIS Administration Functions
Update
Update is used to add additional information to the existing TIS program
loaded in the hard drive.
Installation
Installation is used to initially load the TIS program. To load: The TIS CD
must be inserted in the DVD drive and activated by pressing the
“Activate CD” button. Once the CD is mounted and the installation
button is pressed, loading takes place automatically.
Data update, Password, KDS,Disc copy and Country code are currently not used for the
U.S. market.
30
Diagnosis and Information Systems
DIS Administration Functions
Update
Update is used to add additional information in the form of an update
floppy or CD ROM to the existing DIS program loaded in the hard drive.
Installation
Installation is used to initially load the diagnosis programs. To load: The
Basis Program must already have been installed. The Programs CD is
inserted into the DVD drive and activated by pressing the “activate CD”
button.
Once the CD is mounted and the installation button is pressed, loading
takes place automatically. Always follow the loading instructions provided in the S.I.B. that accompanies the new DIS software.
Feedback
Statistics
Feedback statistics provides a record of all of the reports entered using
the “Feedback” feature under the “Services” menu. The report may be
downloaded onto a floppy at the end of the reporting period.
Date
Time
The Date and Time may be corrected using the on screen arrows. Once
the values are set, an internal battery maintains the running clock and
date when the DISplus is powered off.
Self-test
The Self test function is used to test the integrity of the internal
components, the drives, the measurement system and the external
measuring cables. Once selected, the self test function offers the
following possible tests to be performed.
• Technical System - Individual tests may be carried out on various hardware
components of the DISplus computer.
• Measuring System - This test checks the integrity of the measurement system and all
of the external cable connections. The test may be carried out on the complete system
or individual cables.
31
Diagnosis and Information Systems
Calibrating
Touchshield
Calibrating Touchshield is used to calibrate the position of the cursor.
Follow the on screen instructions for touching the target areas. The
DISplus will acknowledge the calibration if completed properly.
Language selection is not used for the U.S. market.
General Administration Functions
Update
The Update button in the Admin. column, allows loading a CD ROM or
floppy to update the Basis System.
Paper format
Paper format is used to configure the printer output for DIN paper
(21x30cm) or U.S. letter (8.5x11inch)
Network
Configuration
The Network configuration screen is used to assign and change the I/P addresses of the
DISPlus, Diagnostic Heads and Network printer.
In order to make all of the components above communicate with each other when connected to the workshop network, each device must have a defined I/P address, otherwise
no communication can take place.
The individual I/P addresses are assigned by the Network Installer (ADP or Reynolds &
Reynolds). Only the Network Coordinator for your site should enter or change the addresses for any devices on the Network.
32
Diagnosis and Information Systems
Connection
Setup
The Connection Setup screen is used to:
•
Establish Radio/hardwire communication
with the Diagnostic Head.
•
Terminate Radio/hardwire communication
with the Diagnostic Head.
•
Test the communication with the Diagnostic
Head.
•
Assign a colored band to the Diagnostic Head for identification.
33
Diagnosis and Information Systems