Download RLP-‐1048 Heavy Duty AC to DC Power Supply

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electric power system wikipedia , lookup

Transistor wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Stepper motor wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Multimeter wikipedia , lookup

Three-phase electric power wikipedia , lookup

Islanding wikipedia , lookup

Electrical substation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Ohm's law wikipedia , lookup

Triode wikipedia , lookup

Current source wikipedia , lookup

Distribution management system wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Power MOSFET wikipedia , lookup

Schmitt trigger wikipedia , lookup

Rectifier wikipedia , lookup

Power electronics wikipedia , lookup

Voltage regulator wikipedia , lookup

Surge protector wikipedia , lookup

Stray voltage wikipedia , lookup

Current mirror wikipedia , lookup

Buck converter wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
 RLP-­‐1048 Heavy Duty AC to DC Power Supply Owners Guide (These instructions are intended for use by a technician familiar with electronic products)
•
•
•
•
•
•
•
Power Factor Correction Auto Ranging Input Voltage 100 to 260 VAC Metering: Voltage / Amperage Remote Sense / Remote Control DC-­‐OK TTL signal Short Circuit / Overload / Over Voltage / Over Temperature Protection 3 year warranty DESCRIPTION
The RLP-1048 comes with a built-in meter that can monitor voltage and amperage by simply switching the Knob that is located
to the right of the display (Note: the RLP-1048 can only monitor one input at a time). Along with a metered display the RLP comes with
remote sense and remote control. The RLP-1048 has auto ranging input voltage from 100 to 260 VAC and comes with four layers of
protection short circuit, overload, over voltage, and over temperature.
SPECIFICATIONS
Output Voltage........................................................................................................................................................................ 48.0 VDC
Output Voltage Tolerance............................................................................................................................................................+/- 1 %
Output Amperage ...................................................................................................................................... 8 Amps cont., 10 Amps max
Maximum Power, ................................................................................................................................................................... 500 Watts
Output Voltage Adjustment................................................................................................................................................... 41-56 VDC
Maximum Ripple and Noise..........................................................................................................................................200 mV p-p max
Input Voltage, Auto Ranging......................................................................................................................................... 100-to 260 VAC
Input Frequency Range ........................................................................................................................................................... 47-63 Hz
Maximum AC Current .................................................................................................................7 Amps/120 VAC; 3.5 Amps/240 VAC
Typical Efficiency ............................................................................................................................................................................ 80 %
Max Inrush Current, single cycle ...................................................................................................20Amps/120VAC, 40Amps/240VAC
Short Circuit Protection.............................................................................................................................................. Fold back Limiting
Overload Protection (operates) ................................................................................................................................. typical 110-120 %
Line Regulation.............................................................................................................................................................................50 mV
Load Regulation .............................................................................................................................................. 100 mV (20-100 % load)
Fan Control .................................................................................................................................... Heat sink temp >140 F (60 C) = ON
Over Temperature ........................................................................................................................ >195 F (90 C) auto output shutdown
Rise Time following ON ................................................................................................................................................................50 mS
Hold Time following OFF ............................................................................................................................................................. .2 %
Working Temperature Range ............................................................................................................................ -4 – 140 F(-20 -+ 60 C)
Storage Temperature ..................................................................................................................................... -40 – 185 F (-40 - +85 C)
Withstand Voltage* ................................................................................................................. 1.5 KV @ 10 ma (I/P-O/P, I/P-FG)/1 min
(Continued) ............................................................................................................................. 500 V @ 10 ma (O/P-FG)/1 min
Dimensions ......................................................................................................................................3.5H x 19W x 13D inches, nominal
Weight ............................................................................................................................................................................ 15 lbs, nominal
1
METER CIRCUITS
The panel meter is switched to provide DC output voltage measurement and individual output load current measurement for each
individual module.
When set to the VOLT position, the full scale reading is 60 volts.
When set to the AMP position, the full scale reading is 30 amps.
The meter and associated circuitry accuracy is 10 percent of full scale deflection. Since full scale is 30 amps, a 20 amp current can
vary from 18 to 22 amps indicated. To prevent unnecessary output voltage drops, the meter circuits use the voltage drop of the black
#12 AWG negative return to the module as a meter shunt. The #12 AWG wire provides a nominal 100 mV drop at 30 amps
The meter sensitivity for voltage measurement is 1000 ohms per volt.
BATTERY BACK UP & CHARGER (Optional)
Maximum Power, continuous ................................................................................................................................................. 500 Watts
Auto-revert to Battery or Power Supply .................................................................Provided by dual Shottky diode in OR configuration
Maximum Output Current in Battery Mode ..................................................................................... 40 Amps (limited by Shottky diode)
Maximum Charge Voltage ...................................................................................................................................................... 55.2 VDC
Maximum Recharge Rate ..................................................................................................2 Amps with auto sensing of charge current
Charger Protection ........................................................................................Overload/voltage/temperature/reverse polarity protected
Dead Battery Protection ............................................................................... Short circuit protected with deep discharge start function
AC Input................................................................................................................... 90-130 / 180-260 VAC, 47-63 Hz, switch selected
Visual Indication ...................................................................... Bi color LED indication: Red = high rate charge, Green = Float charge
LOW VOLTAGE DISCONNECT with RELAY (Optional)
Maximum Interrupt Current / continuous current ................................................................................................................40 Amps DC
Disconnect Voltage.................................................................................................................................................................... 42 VDC
Reconnect Voltage .................................................................................................................................................................... 50 VDC
Disconnect Delay.......................................................................................................2 minutes @ less than preset disconnect voltage
INSTALLATION WARNING
WARNING: THERE ARE NO USER SERVICEABLE PARTS INSIDE. SERVICE AND REPAIR MUST BE REFERRED TO
QUALIFIED FACTORY PERSONNEL.
NOTE: The individual user should take care to determine, prior to use or installation, whether this device is suitable, adequate or safe
for the use intended. Since individual applications are subject to great variation, DuraComm makes no representation or warranty as to
the merchantability, suitability or fitness of these units for any specific application.
NOTE: The precision regulated power supplies operate internally from voltages in excess of 12/24/48 volts. In rare cases, voltage
spikes or transients on the AC power line, or over heating, may cause a component failure in the power supply. Overloading the output
will cause the over current feature to operate. In either case, the cause must be determined and corrected.
Failures require investigation as to cause and/or repair of the unit.
INSTALLER NOTES
NOTE: DO NOT block any of the cooling vents on the sides and always allow adequate ventilation by not installing the unit inside
tightly closed spaces. Physical mounting position is not critical but the cooling vents must not be blocked.
NOTE: The outputs are NOT referenced to the chassis. The Modular System can be used either positive or negative ground.
2
INSTALLATION BLOCK DIAGRAM
CONDUCTOR PRETREATMENT
All kinds of copper conductors can be clamped without treatment. DO NOT solder tin stranded conductors. The solder yields and
fractures under high pressure. The result is increased contact resistance and excessive temperature rise. Additionally, corrosion has
been observed due to the fluxes. Notch fractures at the transition from the rigid tinned part to the flexible conductors are also possible.
Ferrules can be used as a protection when wiring stranded conductors. Copper ferrules prevent the current transfer from being
influenced by dissimilar metals and remove the risk of corrosion. Always use the correct tool to crimp the ferrule.
RECOMMENDED COPPER WIRE SIZE FOR CURRENT CAPACITY
(Insulated Wire, Single Conductor in free air)
Current Level in Amperes
<7 AMPERES
Wire Size
20 AWG Up to 5 feet
18 AWG Up to 10 feet
18 AWG Up to 5 feet
16 AWG Up to 10 feet
16 AWG Up to 5 feet
14 AWG Up to 10 feet
14 AWG Up to 5 feet
12 AWG Up to 10 feet
12 AWG Up to 5 feet
10 AWG Up to 10 feet
10 AWG Up to 5 feet
8 AWG Up to 10 feet
8 AWG Up to 5 feet
6 AWG Up to 10 feet
6 AWG Up to 5 feet
4 AWG Up to 10 feet
14 AMPERES
20 AMPERES
30 AMPERES
40 AMPERES
50 AMPERES
70 AMPERES
100 AMPERES
3
LIMITED WARRANTY
DuraComm warrants to the initial end user, each power supply manufactured by DuraComm to be free from defects in
material and workmanship, when in normal use and service for a period of three year from the date of purchase, from an
authorized DuraComm dealer.
Should a product manufactured by DuraComm fail or malfunction due to manufacturing defect, or faulty component,
DuraComm, at its option, will repair or replace the faulty product or parts thereof, which, after examination by
DuraComm, prove to be defective or not operational according to specifications in effect at the time of sale to the initial
end user. The product that is replaced or repaired under the provisions of this warranty, will be warranted for the
remainder of the original warranty period, only, and will not extend into a new three year warranty period.
The limited warranty does not extend to any DuraComm product which has been subject to misuse, accidental damage,
neglect, incorrect wiring not associated with manufacture, improper charging voltages, or any product which has had the
serial number removed, altered, defaced, or changed in any way.
DuraComm reserves the right to change, alter, or improve the specifications of its products at any time, and by so doing,
incurs no obligation to install or retrofit any such changes or improvements in or on products manufactured prior to
inclusion of such changes.
DuraComm requires any product needing in or out of warranty service to be returned to DuraComm. All requests for
warranty service must be accompanied by proof of purchase, such as bill of sale with purchase date identified. DuraComm
is not responsible for any expenses or payments incurred for the removal of the product from its place of use,
transportation or shipping expenses to the place of repair, or return expenses of a repaired or replacement product to its
place of use.
The implied warranties which the law imposes on the sale of this product are expressly LIMITED, in duration, to the three
(3) year time period specified herein. DuraComm will not be liable for damages, consequential or otherwise, resulting from
the use and operation of this product, or from the breach of this LIMITED WARRANTY.
Some states do not allow limitations on the duration of the implied warranty or exclusions or limitations of incidental or
consequential damages, so said limitations or exclusions may not apply to you. This warranty gives you specific legal
rights which vary from state to state.
This warranty is given in lieu of all other warranties, whether expressed, implied, or by law. All other warranties,
including WITHOUT LIMITATION, warranties of merchantability and fitness or suitability for a particular purpose, are
specifically excluded. DuraComm reserves the right to change or modify its warranty and service programs without prior
notice.
DuraComm ® Corporation
6655 Troost Avenue
Kansas City, MO 64131
Phone (816) 472-5544 Fax (816) 472-0959
www.duracomm.com
Version 0429-14