* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Product
History of electric power transmission wikipedia , lookup
Standby power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Electrification wikipedia , lookup
Electric battery wikipedia , lookup
Audio power wikipedia , lookup
Power over Ethernet wikipedia , lookup
Alternating current wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
Buck converter wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Rechargeable battery wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power inverter wikipedia , lookup
Powerware 9305 9910 - P95 Reliable power with proven double conversion online technology p95pres.ppt Rev 15.04.04 1 P95 Features • Double-conversion, online technology protects against the 9 power problems • ABM® technology doubles battery service life • Hot Sync™ paralleling technology* allows parallel operation of up to 4 UPS units for maximum reliability • Extended Battery Modules prolong battery runtime • Transformerless UPS design with 3-phase bypass • Includes one-year ProActive Service Plan Product Snapshot Power Rating: 30 kVA / 21 kW Voltage: 380/220V, 400/230V, 415/240V Frequency: 50/60 Hz Input Connection: Hardwired Output Receptacles: *N+X redundancy feature is available through IBM Global Services. (2) 3-phase 32A with PN 97P3702, (3) IEC varies 2 P95 Applications The P95 was specifically designed, engineered and approved for IBM applications • • • • • • • • • iSeries and AS/400 pSeries and RS/6000 xSeries and other eServers Storage and networking devices Server farms Networking Telecommunications Medical Small data centers P95 is the ideal power protection for pSeries 690 Regatta (image shown above) and the iSeries 890 (image shown on the left). 3 Series 9 Power Protection The P95 provides double-conversion online power protection from all 9 of the most common power problems that threaten your equipment and data Power failures High voltage spikes Power sags Frequency variations Power surges Switching transients Brownouts Harmonic distortion Line noise 4 Lowest Cost of Ownership – In normal operational mode (online, double conversion) continuous power protection with very high efficiency (>96%) – In Energy Optimiser Mode - dynamically optimized performance • Stable utility power - continuous line filtering with highest efficiency • Unstable or out-of-tolerance utility power – automatically resumes online double conversion operations without operator intervention – Intelligent programmable operation allows switching between modes without operator intervention. There is NEVER a trade off between EFFICIENCY and AVAILABILITY 5 Compact Footprint 520 mm wide 1530 mm high Dimens ions : Height 30 kVA (mm) (in) 1530 60 Width Depth 520 20.5 790 31 Weight: 490 kg (1080 lb.) 790 mm deep 6 Extended Battery Modules • Prolong battery runtimes with up to 3 EBMs per P95 • Line up and match cabinets – – – – Width: 520 mm (20.5 in.) Depth: 790 mm (31 in.) Height: 1530 mm (60 in.) Weight: 920 kg (2024 lb.) 7 System Configurations • The P95 can be used in parallel configurations* of up to four UPS modules • Paralleling the UPSs makes systems easily scalable • Achieve redundancy by adding one UPS module more than required to support the critical load *N+X redundancy feature is available through IBM Global Services. 8 P95 Technical Specifications VA / Watts Rating: 30 kVA / 21 kW Input Voltage: 380/220V, 400/230V, 415/240V Output Voltage: 380/220V, 400/230V, 415/240V Input Voltage Range: 170/294 279/484 Vac, 50 Hz Operating Frequency: 50-60 Hz (45 to 65 Hz) Operating Temperature: 0ºC to 40ºC (32ºF to 104ºF) Storage Temperature: 15ºC to 25ºC (59ºF to 77ºF) Relative Humidity: 15-90% RH non-condensing Audible noise: Less than 55 dBA at one meter Typical Runtime: 7 minutes at full load, 18 minutes at half load 9 One Line Diagram Optional External Battery Cabinet 9910-P95 30 kVA UPS (Can be down-rated to 20 kVA) Options Cabinet ** 3-pole 50A D-type Rectifier Input Breaker ** 3-pole 50A D-type Bypass Input Breaker INPUT FILTER Input Choke Rectifier EXTERNAL UPS MAINTENANCE BYPASS SWITCH Inverter (Allows the UPS to be fully maintained without disrupting power to the load) Static Bypass OUTPUT CIRCUIT BREAKERS (Wired to terminals for ease of installation and maintenance) BATTERIES Internal Batteries Internal Maintenance Bypass SPARE WAYS FOR FUTURE EXPANSION ** Note: Not included with the 9910-P95 UPS package ** IBM EQUIPMENT 10 Efficiency Optimiser™ • In standard system, high efficiency mode can be activated by the operator forcing the P95 to use the bypass source when the mains power quality is acceptable for the load. • The P95 transfers to double conversion or battery if a serious power problem threatens the load • Efficiency Optimiser™ cuts down the electrical bill by minimising power losses 11 P95 Normal Mode Traditional Double Conversion Online Operation B YP AS S UT IL IT Y OUT P UT B AT T E R Y P OWE R F L OW Inverter powers load with bypass in standby – Inverter powered by utility via rectifier and boost converter – Battery in standby, (charging or resting) • Conditions: Input within specified range (typically +/- 15%) Selected preferred mode Bypass quality unacceptable 12 Energy Optimiser Mode User selectable, high efficiency parallel source operation BYPASS UTILTIY OUTPUT BATTERY POWER FLOW Bypass and inverter operate (inverter in hot-standby) – Bypass provides power (kW) and inverter stands ready to operate when and if input voltage exceeds preset range – Battery in standby, (charging or resting) • Conditions: Bypass within specified range (typical +/- 5%) Bypass quality acceptable Not on generator 13 P95 Battery Mode BYPASS UTILITY OUTPUT BATTERY POWER FLOW Inverter powers load from battery source – Inverter powered by battery • Conditions: Utility failed or outside acceptable window 14 P95 Bypass Mode BYPASS UTILITY OUTPUT BATTERY POWER FLOW Bypass circuit powers load – Load powered by bypass with inverter off • Conditions: UPS output overload Inverter circuit failure Temporary user-selected mode 15 P95 Battery Runtimes Battery Runtime (in minutes)* VA 10,000 15,000 20,000 25,000 30,000 Standard (Std) Internal Batteries 30 18 12 9 7 +1 EBM (FC 6636) 160 105 70 52 42 +2 EBMs (FC 6636) 390 200 140 110 85 +3 EBMs (FC 6636) 510 330 240 185 120 16 Powerware Extensions Software for IBM Director • • • • • Seamless UPS and software integration into IBM Director Network Management System (NMS) Real time monitoring, management and alarm notification of all UPSs in the network: e.g. battery status, battery replacement, load level and metering information Automatically launches LanSafe and ConnectUPS Web/SNMP Card applications from within Director Available on Powerware web FREE-OF-CHARGE 17 Power Management Software Powerware Software Suite The industry’s most comprehensive software bundle, The Powerware Software Suite, is free and included with every P95. Software Wizard guides you through software selection and installation. In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite contains the following power management software: • • LanSafe™ Network UPS shutdown and monitoring software PowerVision® (30-day trial version) UPS performance analysis and monitoring software • OnliNet Centro SNMP shutdown software • Foreseer® (demonstration) facility and data center management software 18 Software Application Application LanSafe Single pSeries (serial/TTY) non-LPAR ! Single pSeries (network) non-LPAR !* Multiple pSeries (LPAR) !* !* Single pSeries (LPAR) Multiple pSeries (non-LPAR) Powerware Extensions for NetWatch IBM Director ! !* !* IBM Director Network Device * !* Co-requisite FC 2934 or 2935 ConnectUPS Web/SNMP network card. Note: UPS for iSeries applications utilize OS/400 UPS monitoring functions. 19 Software Comparison Application LanSafe NetWatch ConnectUPS Web/ SNMP Card SSL/SSH1 Security Ambient Temperature Humidity Monitoring Shutdown GUI Email/ SMTP Yes Yes Yes Yes / Yes No/No No/No - Yes - No/No No/No No/No Yes2 Yes3 Yes Yes / Yes Yes / Yes Yes / Yes4 1SSL = Secure Sockets Layer. SSH = Secure Shell. 2Via Web Browser, LanSafe or Network Management System (e.g. IBM Director, Tivoli). 3In conjunction with NetWatch software. 4With optional FC 2938 EMP (Environmental Monitoring Probe) device attached. 20 Connectivity What you need by application Software Solution zSeries iSeries LanSafe ! LanSafe and ConnectUPS MultiServer card (IBM FC 2933) NetWatch and ConnectUPS Web/SNMP card (IBM FC 2934 or 2935) ! pSeries xSeries ! ! !! LPARs ConnectUPS Relay card and AS/400 cable (IBM FC 2936) ! Networking ! ! ! ! ! ! ! ! ! ! Powerware Extensions for IBM Director NetWatch Storage ! ! !Use ConnectUPS Web/SNMP/xHub card, IBM FC 2934 or 2935 to support LPAR (POWER 4 Chip Set) servers. For pSeries configurations, each LPAR needs a network connection and will install Powerware provided NetWatch or LanSafe 5 software. 21 P95 Site Evaluation • Powerware site evaluation is available five days a week during normal business hours (5x8) prior to installation. • During the evaluation, the Powerware Power Consultant will: – Work with IBM IPR to determine output connection requirements – Contact customer to discuss UPS installation and output configuration. If only new IBM supplied equipment will be connected to the UPS, a site visit will not be required. – Provide site visit report to IBM. 22 P95 Collateral • Additional information available at www.oem.powerware.com/ibm-ups – Select your region. Click “Products”, click “9910 Solutions” then click “Powerware pSeries” or “Powerware iSeries” • Materials available – – – – Data sheet Application overview chart Product presentation Documents (manuals) 23