Download CT430900 v1.0

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Rectifier wikipedia , lookup

Relay wikipedia , lookup

Fault tolerance wikipedia , lookup

Power inverter wikipedia , lookup

Buck converter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Control system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power engineering wikipedia , lookup

Stray voltage wikipedia , lookup

Electrical substation wikipedia , lookup

Three-phase electric power wikipedia , lookup

Power electronics wikipedia , lookup

Metadyne wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Bus (computing) wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
ON/OFF Actuator
CT430900
v1.0
General description
Installation
CT430900 is an actuator composed of 9 potential-free relay
outputs (dry contact). Each output could work independently
or simultaneously in different modes: binary outputs, blinds,
Fan-coils or thermo-valves. Support for Arithmetic and Logic
Unit (UAL) that allows to program complex logic operations,
timers programming, counters, etc. using internal or external
variables.
Characteristics


Its 9 outputs allow to control 9 on / off electrical circuits,
4 blinds (2 outputs for one blind motor: up phase and
down phase) or 2 Fan-coils. The cut off capacity is
16A@230VAC / potential free relay output. If necessary,
insert a contactor to control higher power circuits
Last position memory in case of power failure
Technical information
Supply
Consumption
Mounting
Connections
Outputs
Breaking power
Environment
temperature
range
Regulation
29Vdc from KNX BUS
9 mA from KNX BUS
DIN Rail (6 modules)
KNX connecting terminal bus
Screw terminal block for inputs and
outputs.
9 digital outputs (potential-free
relay) 16A@230VAC cut-off
capacity.
16A @ 230Vac
Operation: from -10ºC to 55ºC /
Storage: from -30ºC to 60ºC /
Transportation: from -30ºC to 60ºC
According to the directives of
electromagnetic compatibility and
low voltage. EN 50090-2-2 / UNEEN 61000-6-3:2007 / UNE-EN
61000-6-1:2007 / UNE-EN 61010-1
Observations
Install low voltage lines (KNX bus and inputs) in a ducting
separated from the power (230V) and outputs lines ducting to
ensure there is enough insulation and avoid interferences.
Do not connect the main voltages (230V) or any other
external voltages to any point of the KNX bus or inputs.