* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download CT430900 v1.0
Fault tolerance wikipedia , lookup
Power inverter wikipedia , lookup
Buck converter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Control system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power electronics wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
ON/OFF Actuator CT430900 v1.0 General description Installation CT430900 is an actuator composed of 9 potential-free relay outputs (dry contact). Each output could work independently or simultaneously in different modes: binary outputs, blinds, Fan-coils or thermo-valves. Support for Arithmetic and Logic Unit (UAL) that allows to program complex logic operations, timers programming, counters, etc. using internal or external variables. Characteristics Its 9 outputs allow to control 9 on / off electrical circuits, 4 blinds (2 outputs for one blind motor: up phase and down phase) or 2 Fan-coils. The cut off capacity is 16A@230VAC / potential free relay output. If necessary, insert a contactor to control higher power circuits Last position memory in case of power failure Technical information Supply Consumption Mounting Connections Outputs Breaking power Environment temperature range Regulation 29Vdc from KNX BUS 9 mA from KNX BUS DIN Rail (6 modules) KNX connecting terminal bus Screw terminal block for inputs and outputs. 9 digital outputs (potential-free relay) 16A@230VAC cut-off capacity. 16A @ 230Vac Operation: from -10ºC to 55ºC / Storage: from -30ºC to 60ºC / Transportation: from -30ºC to 60ºC According to the directives of electromagnetic compatibility and low voltage. EN 50090-2-2 / UNEEN 61000-6-3:2007 / UNE-EN 61000-6-1:2007 / UNE-EN 61010-1 Observations Install low voltage lines (KNX bus and inputs) in a ducting separated from the power (230V) and outputs lines ducting to ensure there is enough insulation and avoid interferences. Do not connect the main voltages (230V) or any other external voltages to any point of the KNX bus or inputs. QR Code Ingenium, Ingeniería y Domótica S.L. - Parque Tecnológico de Asturias, Parcela 50 - 33428 Llanera, Asturias, Spain T (+34) 985 757 195 - [email protected] - www.besknx.com - www.ingeniumsl.com