Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
MaxSave Multifunction Power Meter MAX 3100 SERIES NSK ELECTRIC CO.,LTD 721/1 Moo.5 T.Nongkham A.Sriracha Chonburi 20230 Thailand Tel. 038-060-588,038-762-443 Fax.038-060-589 ,038-762-446 Product Profile MAX3100 is a powerful multifunction power meter that can measure more than 60 parameters such as U,I,P, Q, cos o ,F, kWh, kvarh, etc. The standard MAX3100 has RS-485 communication protocol, 2 energy pulse outputs (active and reactive each) functions. With optional module, MAX3100 can perform more functions as harmonic analysis, 8 digital signal inputs, 4 programmable relay outputs, 4 programmable analog outputs (0-5V or 4-20mA). data storage. Profibus communication, Ethemet metworking capabilities. Applying modular design. MAX 3100 works flexibly to suit customers'needs. MAX 3100 LCD front panel and main unit can be connected or separated; the main unit alone can work as a data acquisition module. MAX3100 fulfills ass the important requirement of IEC60687(GB/T17883-1999),C1268(GN/T17882-1999), IEC 61000-4-30, GB/T 14549-1993, IEC688-1992,GB/T13850-1998. Measured scope : Single phase, 3P3W system. EMC and other safety standard IEC61000-4-2 : 1995 (GB/T17626.2-1998) IEC61000-4-8 : 1995 (GB/T17626.8-1998) IEC61000-4-4 : 1995 (GB/T17626.4 -1998) IEC61010-1 : 1990 (GB/T4793.1-1995) Functions Description Real time measurement Main unit Phase Voltage Line Voltage Current Active Power Reactive Power Apparent Power Power 4 quadrant Frequency Power Factor Phase Voltage, average phase Voltage Line Voltage, average line Voltage Phase Current, average phase Current, zero sequence Current Phase active Power, 3 phase active total power Phase reactive Power, 3 phase reactive total Power Phase apparent Power, 3 phase apparent total Power Power 4 quadrant System frequency Phase Power factor, 3 phase total Power factor Demand statistic Demand 3 phase active/reactive demand Power, demand apparent Power Active Energy Reactive energy Multi tariff billing Imported, exported and net acive energy, 1 channel active energy pulse output Energy Reading Real time display Year/month/day/hour/minute/second RS-485 communication 1 Modbus-RTU protocol 8 Channels Status detecion, SOE event record Relay output 4 channels programmable Programmable over/under limit value for real time measurement, Volt- module overlimit/underlimit alarm age/Current unbalanced ratio,demand value,harmonics, remote signal. Analog output module 4 channels programmable Time Display Data communication Remote signal input module Imported,exported and net reactive energy,1 channel reactive energy pulse output Multi tariff setup The overlimit/underlimit command can be read thru com. Port Data storage module 4 - 20mA or 0-5V Store real time measured value in cycle, Voltage/Current. unbalanced ratio, demand value, harmonics, remote signal. Storage capacity : 8GB optional Module Harmonic analysis module Total harmonic distortion for Voltage/Current Even/odd harmonic distortion Fundermental Voltage/Current 3 phase, single phase, neutral line Harmonic distortion ( 2nd to 63rd) Magnitude, phase angle Fundermental active/reactive power Harmonics, individual Magnitude, phase angle Current K factor Profibus communication module Ethernet networking communication module 1 channal Profibus protocol 10M/100M adaptable TCP/IP com. Protocol 1 channal Visit Webpage, send email periodically,and send event record information Measurement Accuracy Parameters Voltage Current Power factor Frequency Active Power Reactive Power Apparent Power Active Demand Reactive Demand Active Energy Reactive Energy Display 0~9999.9KV 0~9999.9KV -1~+1 45 ~ 65Hz -999999 ~ 999999MW -999999 ~ 999999Mvar -999999 ~ 999999MVA -999999 ~ 999999MW -999999 ~ 999999MVar 0 ~ 999999999MWh 0 ~ 999999999Mvarh Phase Angle Curren total harmonic % Voltage total harmonic % 0.0. ~ 359.9 . 0 ~ 100% 0 ~ 100% Direction Directional Directional Directional Directional Directional Directional Class0.2 Class0.2 Class 1 0.01Hz Class0.5 Class0.5 Class0.5 Class 1 Class0.5 Class0.5 Class 1 Class 2 Class 2 Class 2 Technical Specification Power consumption: ≤0.2VA per phase Voltage Input Input Voltage: 0~400VAC (L-N),0~690VAC (L-L) (Voltage value can be set up) System frequency: 45~65Hz Profibus com.module (optional) No. of channels Communication protocol Profibus-DP protocol Ethernet networking module (optional) No.of channels: 1Chanel 10M/100M adaptive Communication protocol TCP/IP protocol Other parameters Auxiliary Power 85~265VAC/DC (standard) 24~80VAC/DC (optional) Measurement scope: 3%~120%Un Display module Input Current Input Current: 0~5A (Current value can be set up) Measurement scope : 0.5%~120%In Overload capacity : 2Xrated continuously, 100A/1s non continuously Overload Capacity: 2Xrated continuous,2500V/1s non continuous LCD Display 76mmx66mm luminosity con be adjusted Power consumption: ≤ 0.5VA per phase Switch Status (Optional) Input Chaneles 8 channels Input Type Dry contact Contact Capacity 2500VAC Relay output (optional) Output Chanels 4 Channels programmable Output Type Mechanic contact, constant on output Contact Capacity 5A/250VAC Analog output (optional) No.of outputs 4 Chanels programmable 2GB <100PPM/. C Withstand Voltage(input against output) 2500V/1min Total power consumption <8VA -20. C ~ 60. C Operation temperature -40. C ~ 85. C Storage temperature Operation humidity 5~95%RH Pollution Class Class 2 Material of Housing Flammability acc.to UL94V0 Dimensional Size:Front panel+main unit, 96x99x78mm, front+main+optional module 96x99x121mm Output signal Response time Dimensional Size:Main unit main + module 92x112x74mm 92x112x114mm Dimensional Size:Front panel 96x99x41mm Installation Size:Front panel+main unit 91x91mm 4 ~ 20mA or 0~5V ≤ 400ms Pulse output (standard) No.of outputs 2 channels (active/reactive energy each) Serial com.port (standard) No.of outputs 1 RS-485 port Communication protocol Modbus-RTU protocol Baud rate 2400/4800/9600/19200/38400bps Storage Capacity Temp.drifting factor (+module) Connection and Installation I. Integrated Front panel + main unit (+module) connection ______Default type MAX3100 inteqrated connection is mainly for panel installation. II. Main unit (+module) connection______no display, for data acquisition purpose MAX3100 con transmit the measured parameters thru com. Port to other device. This installation unit can be installed on 35mm rail or bolted in the cainet. III. Front panel and main unit(+module)separated connection ____customized installation The front panel can be installed on the front panel of cabinet; the main unit can be installed on 35mm DIN rail or bolted in the cabinet. These two are connected by wire (length of wire is 0.5/1/1.5/2m). Customized length of wired is offered. Dimensional and Size Diagram