ON inside 12/24/48V These 5 adjustments are not active when a ME-RC Remote Control with revision 1.5 or higher is used. They are set using displays under the AGS button on the remote control. Input DC Voltage jumper - set to Monitored battery bank voltage (on 48V setting) 1 2 3 4 inside ME-AGS wiring diagram – For Honda Generator (EM3800SX • EM5000SX • EM6500SX with Remote Control Box) Dip-switch configuration (3-Wire mode) Remote control connector DC TERMINALS G W/ Bl Honda™ Remote Control Box PILOT LAMP W G Y P RUN TIME HOURS STOP Timing Information STOP Time START Time Time between start attempts Delay Time 10 seconds 10 seconds 2 minutes 4 seconds START SWITCH STOP Delay START STOP SWITCH Relay 2 (pins 6 & 7) W/Bu Ground Relay 1 (pins 5 & 6) G Battery Bank (monitored for gen turn on) Y GEN BATTERY W/Bu 5 amp fuse P Gen Run Signal (input to pin 2 must be 10 to 40 DC volts only while generator is running); this can be the generator hour-meter or a 12vdc pilot/run light Honda Generator Remote Control Box ME-AGS relay timing for 3-Wire Mode Magnum Energy, Inc. provides this diagram to assist in the installation of the Auto-Generator Start controller. Since the use of this diagram and the conditions or methods of installation, operation and use are beyond the control of Magnum Energy, Inc., we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of the installation, operation and use of this unit. 3-23-2010